4
Indicator lights on Frontpanel and switche for safe operation
Doku Nr. 988 Stand 3.2.2016 / Aui
Muting
E2
E4
E6
Ausricht-
kontrollen
P1
P2
Fiessler Elektronik - Kastellstrasse 9 - D 73734 Esslingen - Tel.: 0711/9196970
Empfänger /
Receiver
Typ: AKAS®-3M
OSSD1
OSSD2
OSSD1
OSSD2
SP
SGA
SGO
SGS
Kastenbiegen
box-bending
FIESSLER
E L E K T R O N I K
off
on
FUS
FUO
Adjustment
Typ 4
EN 61496
1
3
4
5
6
Indicator lights
for
in- and outputs
(see page 47)
Inputs for press start / stop
(release of closing stroke)
Input for safety point
Output for demand for slow speed
Input for position control in slow speed
view of the receiver elements
AKAS®-3M
1.2
2
14h
13h
12h
11h
10h
9h
8h
7h
6h
5h
4h
3h
2h
1h
1
2
3
5v
4v
3v
2v
1v
6v
1
SP
SGA
SGO
SGS
FUS
FUO
6
ajustment controll-Leds of the receiver elements E2, E4, E6
LEDs are on if the beam does focus at all (see page 26)
ajustment controll-Leds P1, P2 for self-acting ajustment
after tool change
LEDs are of if the beam does focus at all (see page 26)
integrated mutinglamp
lamp is on if the protective field of the AKAS is not activated
lamp is flashing if EDM- or SP-input-signals are wrong
(see page 47)
LEDs for safety outputs (OSSDs, Fail-Safe PNP)
red LEDs are on if the OSSDs are in OFF status
green LEDs are on if the OSSDs are in ON status
LED is on if box bending funktion is activated
E1
E2
E3
P2
E6
E5
bendingline
P1
E4
connector plug
dip-switches (see page 19)
view after removing the
connection lid on the recei-
ver support
1
2
3
4
5
FIESSLER