Electrical connections - Description / Wiring diagrams
6
-with selectable safety functions
6.5
Doku Nr. 988 Stand 3.2.2016 / Aui
Terminals of the Receiver AKAS®-3F / -IIF
example for operation mode
B8 B8 or F8 F8
example for operation mode
00 00
Nr
1v
designation
SGO
meaning
input
monitoring of slow speed position
signal level
+24V at fast speed
0V at slow speed
signal level
0V at fast speed
+24V at slow speed
2v
3v
4v
5v
SGS
SP
input
monitoring of slow speed position
input
safety point
SGA
HUSP
output
request for slow speed
output
higher mutepoint request (AKAS®3F),
message box bending ( AKAS®-IIF)
0V at fast speed
+24V at slow speed
0V: within fast speed range
+24 V: within slow speed range
0V at fast speed
+24V at slow speedg
+24V: within slow speed range
0V only slow speed permitted
+24V fast-/slow speed possible
+24V if box-bending is selected
0V only slow speed permitted
+24V fast-/slow speed possible
+24V: if box-bending is selected
6v
7v
8v
9v
S_EU2K
NLW
+Ub transmitter EU2K 500/2-
rear guard
with antivalent switching light grid
input
overrun traverse control input
EDMO
EDMS
input
monitoring of the Stop valves
input
monitoring of the Stop valves
10v
11v
12v
13v
NA1
NA2
input
Emergency OFF / rear metal grid
input
rear / lateral metal grid
NA 3
RXOK1
input
Emergency OFF / lateral metal grid
output
drive rear stoppers Emerg. OFF
0V: if activated by cam
24V if not activated by cam switch
0V at closing stroke
+24V at stop
0V: at stop
+24V at closing stroke in fast speed
+24V if grid is closed i.e.
emergency OFF is not activated
+24V if grids are closed
+24V if grid is closed i.e.
emergency OFF is not activated
+24V if enabled
14v
1h
2h
3h
RXOK2
+Motor
output
drive rear stoppers Emerg. OFF
connector for + Motor transmitter support
-Motor
+Ub Sender
connector für - Motor transmitter support
connectiion for +Ub AKAS transmitter
4h
5h
6h
7h
FUS
FUO
input
Start / Stop
closing stroke
input
Start / Stop
closing stroke
KAST / SGW
OSSD1
input
box bending
/
Slow speed traverse information
safety output
release of closing stroke
+24V if enabled
+24V if foot pedal or key switch is
activated
+24V if FUS is triggered or if
key switch is activated
0V Press stop
+24V Press close
+24V Press stop
0V Press close
0V Press stop
+24V Press close
0V Press stop
+24V Press close
box bend.:
+24V pulse min. 100ms
SGW:
+24V if completely muting
+24V if released
+24V pulse min. 100 ms
+24V if released
8h
9h
10h
11h
OSSD2
+Ub 24VDC
safety output
release of closing stroke
power supply
-Ub 0V
-Ub Sender
power supply
connection for -Ub AKAS-transmitter
12h
13h
14h
RS 232 GND
RS 232 out
message output (State-/error )
messaage output (State-/error)
Erde
functional ground
+24V if released
+24V if released
Terminals of the transmitter
Nr
5
designation
Erde
meaning
Functional ground
4
3
1
2
-S
+S
-Ub transmitter
+Ub transmitter
+Motor
-Motor
+ Motor transmitter support
- Motor transmitter support
inputs
switching
antivalent
inputs
switching
equivalent
inputs
switching
antivalent
inputs
switching
equiva-
lent
AKAS®-3F / AKAS®-IIF
FIESSLER
E L E K T R O N I K
Use the grey marked
connections depen-
ding on ceased type
(see p.45/46)