![Fiessler AKAS-3F Operating Instructions Manual Download Page 19](http://html1.mh-extra.com/html/fiessler/akas-3f/akas-3f_operating-instructions-manual_2288055019.webp)
The press must have
an automated overrun traverse control for the first stroke. If not, it can be realised by
the AKAS®-...F and a cam controller or by the Fiessler AMS-system . Before the initial start-up, the overrun tra-
verse must be checked either by using the test rod (see page 9) or by using an Overrun Traverse measuring
device.
(upon customer's request, Fiessler Elektronik will perform the Overrun Traverse Measuring on the customer's machine.)
If the results of 10 consecutive measurements are larger than 15mm (AKAS®-LC...), 14mm (AKAS®-II...) bzw.
13mm (AKAS®-3...) , the fast speed must be reduced.
According to the induvidual overrun traverses of each machine, 8 different distances Z
(=gap betrween uppermost receiver ele-
ment and bending punch, see Fig. 19/1 u. Fig. 19/2)
can be programmed via 3 dis switches at the support. The adjustment to the re-
spective selected distance is carried out automatically. (s. chapter 5.7 (Adjustment of the distance of the AKAS® from
the bending punch). Fiessler delivers the system pre-adjusted "A".
Mounting
How to proceed: Step by
step mounting the AKAS®
1a. Overrun Traverse
Measurement
1b. adjustment of the dip
switches
only AKAS®-II...
and AKAS®-3...
19
5
How to proceed when mounting the AKAS®
5.1
Doku Nr. 988 Stand 3.2.2016 / Aui
1
a. Overrun traverse measurement / b. Dip switch adjustment at the support
2
3
Design of the mechanical holders
- void if Fiessler holders are used
Mounting of the holders at the ram
4
5
6
7
Mounting of the AKAS® on the holders
Connection of the AKAS® / Selection of the operating mode
at the ...F-series
Adjustment of the AKAS® during first installation
Adjustment of the distance of the AKAS® from the bending punch
(self-acting if supports are used)
8
9
Function Verification of all electrical connections in view of the safety classs 4 requirements
Self-acting Overrun Traverse Test
Overrun Traverse Measurement / According dip switch adjustment
5.2
E1
Z
fig.19/1
Mark
E2
Z
Mark
fig.19/2
AKAS®-3
AKAS®-II...
* by this, a tolerance in
sheet metal waviness
of about 2mm is given.
Table19/1
A
13 mm
14 mm
13 mm
22 mm
16 mm
B
C
11 mm
9 mm
12 mm
10 mm
11 mm
9 mm
20 mm
18 mm
14 mm
12 mm
D
E
F
G
8 mm
7 mm
9 mm
8 mm
6 mm
5 mm
7 mm
6 mm
8 mm
7 mm
6 mm
5 mm
17 mm
16 mm
11 mm
10 mm
15 mm
14 mm
9 mm
8 mm
H
4 mm
5 mm
4 mm
13 mm
7 mm
adjust-
ment
distance Z
after completed
automatical ad-
justment
max. allowable overrun tra-
verse of the press brake after
the interruption of the beams
AKAS®-II... / AKAS®-3...
Dip switch Position
recommended change-over point
(U) from fast speed into slow
speed
*
above the slug surface
AKAS®-II... / AKAS®-3...
off
on
off
on
off
on
off
on
off
on
off
on
off
on
off
on
FIESSLER