System Trouble         

Address   

System Trouble         

Address 

LOOP CONTINUITY TEST FAIL LOOP 3            

231 

 

WALK TEST - FIRE PROTECTION IS LIMITED      

485 

LOOP CONTINUITY TEST FAIL LOOP 4            

232 

 

REMOTE PROG MODE ACCESSED                   

486 

LOOP CONTINUITY TEST FAIL LOOP 5            

233 

 

DIA PROG. CHANGE DET. SERVICE REQUIRED      

487 

LOOP CONTINUITY TEST FAIL LOOP 6            

234 

 

ISIB DATA MESSAGE RECEIVED ERROR            

488 

LOOP CONTINUITY TEST FAIL LOOP 7            

235 

 

ISIB EXECUTIVE ROUTINE RE-ENTERED           

489 

LOOP CONTINUITY TEST FAIL LOOP 8            

236 

 

DIB TO SIB CABLE BAD OR MISSING             

490 

LOOP CONTINUITY TEST FAIL LOOP 9            

237 

 

UPLOAD/DOWNLOAD MESSAGE RECEIVED            

491 

LOOP CONTINUITY TEST FAIL LOOP 10           

238 

 

GLOBAL DATABASE MISMATCH                    

492 

AMP FAIL                                    

239 

 

SIB PROG. CHANGE DET. SERVICE REQUIRED      

493 

AC FAIL                                     

240 

 

HS-NCM SNIFFER MODE ACTIVE                  

494 

SCB ASSEM. COM. VERIFIED FAILED             

241 

 

EXCEEDED CONNECTION LIMIT                   

495 

8255 PORT CHIP CONTROL WORD CHECK FAILE      242 

 

NAM CCBE. PROG LOST                         

496 

NETWORK COMMUNICATION LINK FAIL PORT A      243 

 

MEMORY LOSS                                 

497 

NETWORK COMMUNICATION LINK FAIL PORT B      244 

 

DVC COMM LOSS                               

498 

STYLE 4 SHORT A L1                          

245 

 

A.C. POWER LOSS. BACK UP ACTIVATED          

499 

STYLE 4 SHORT B L1                          

246 

 

BUZZER OFF-LINE                             

500 

STYLE 4 SHORT A L2                          

247 

 

PANEL DOOR OPEN                             

501 

STYLE 4 SHORT B L2                          

248 

 

OFF NETWORK                                 

502 

STYLE 4 SHORT A L3                          

249 

 

INSTALL. ERROR                              

503 

STYLE 4 SHORT B L3                          

250 

 

OR AUDIO/TELEPHON                           

504 

STYLE 4 SHORT A L4                          

251 

 

EXPANDER MODULES                            

505 

STYLE 4 SHORT B L4                          

252 

 

MANUAL CONTROL                              

506 

STYLE 4 SHORT A L5                          

253 

 

CAT. COMM. FAULT                            

507 

STYLE 4 SHORT B L5                          

254 

 

UNKNOWN                                     

508 

Appendix A.3.

 

Node Status 

 

Data for any particular Node is valid while that Node is online and the system is synchronized.  Integrity of 
data for any Node will be lost if the Node goes offline or if synchronism between the FieldServer and the 
NCA2 Panel is lost. 

 

Node status offline/online (1/0) is stored in the 502

nd

 address.  It is important to read the Node status 

before reading any information about the Node.  

 

Node status data integrity itself depends upon system synchronization.  

Appendix A.4.

 

FieldServer Synchronization 

There is currently no method of auto-synchronizing the FieldServer's Data Arrays with the Notifier NCA2/NFS2-
3030 panel because there is no method for polling the panel through the printer or CRT port.  Synchronization of 
the two devices can be achieved manually pressing the “System Reset” button on the panel while the FieldServer is 
connected and running.  All current events will be re-sent to the FieldServer.. 

Summary of Contents for NCA2-NFS2-3030

Page 1: ...ITY EFFECTIVITY Effective for all systems manufactured after January 2009 Driver Manual Supplement to the FieldServer Instruction Manual FS 8700 130 Notifier NCA2 NFS2 3030 Driver Version 1 02 Document Revision 1 ...

Page 2: ... 2 Data Arrays Descriptors 8 4 3 Client Side Connection Descriptions 9 4 4 Client Side Node Descriptors 9 4 5 Client Side Map Descriptors 10 4 5 1 FieldServer Related Map Descriptor Parameters 10 4 5 2 Driver Related Map Descriptor Parameters 10 4 5 3 Map Descriptor Example Standard example 11 5 Configuring the FieldServer as a Notifier NCA2 NFS2 3030 Server 12 Appendix A Advanced Topics 13 Append...

Page 3: ...itored by third party tools Since the FieldServer does not actively poll for data the accuracy and timeliness of the stored data is limited to the frequency of update messages that the Notifier Fire Panel issues If a networked panel does not send the CLEARED message for latched points via the NCA2 it is not possible to detect cleared points unless a system reset is done It is possible to configure...

Page 4: ...n drawing Configure the Notifier Panel according to manufacturer s instructions FieldServer FieldServer Part 8917 16 Pigtail for RJ45 Port RJ45 Connection to TB5 Printer Port Notifier NCA2 NFS2 3030 Connect to one of the RS 232 Ports on the FieldServer P1 CTX CRX REF PTX PRX REF TB5 Printer CRT Rx Brown Tx Orange White Com Blue White 1 8 Connector Pinouts TB5 CRT Function Receive Reference Transmi...

Page 5: ...l 408 262 2299 Fax 408 262 2269 Toll Free 888 509 1970 email support fieldserver com 3 1 Hardware Connection Tips Hints The FieldServer should preferably be connected to the TB5 Printer port It is theoretically possible to connect to the TB5 CRT port but this has not been fully tested The Panel s port must be enabled and set to 80 Columns Not Supervised ...

Page 6: ...ing the text messages sent to the printer or CRT port Not all messages will be interpreted as many messages do not directly pertain to device status or are not currently supported The following subset of event messages is recognized Active Events FIRE ALARM SECURITY ALARM LIFE LIFE CRITICAL ALARM MEDICAL EMERGENCY SECURITY ALARM CRITICAL PROCESS SUPERVISORY TROUBLE FAULT DISABLED PREALARM ACTIVE O...

Page 7: ...Active 1432 1590 ON OFF 1591 1749 Memory Type Detector_Trouble Module_Trouble Troubles Faults 1 159 Parameter Addresses For each Node Memory Type Node_Trouble Troubles Faults 1 508 Memory Type Panel Panel Maximum12 Boards and 8 Panel circuits per Board Hardware address memory address Board 1 panel 1 1 Board 1 panel 2 2 Board 2 panel 1 9 Board 12 panel 8 96 Fire Alarm 1 96 Security Life 97 192 Life...

Page 8: ...ide Map Descriptors section Details on how to do this can be found below Note that in the tables indicates an optional parameter with the bold legal value being the default Section Title Data_Arrays Column Title Function Legal Values Data_Array_Name Provide name for Data Array Up to 15 alphanumeric characters Data_Array_Format Provide data format Each Data Array can only take on one format Bit Sin...

Page 9: ...its Specify data bits 8 Vendor limitation Stop_Bits Specify stop bits 1 Vendor limitation Example Client Side Connections Connections Port Protocol Baud Stop_Bits Parity P8 nfs2 nca 9600 1 None 4 4 Client Side Node Descriptors Section Title Nodes Column Title Function Legal Values Node_Name Provide name for Node Up to 32 alphanumeric characters Node_ID Station address of any physical Node on netwo...

Page 10: ...riptor Passive 4 5 2 Driver Related Map Descriptor Parameters Column Title Function Legal Values Node_Name Name of Node to fetch data from One of the Node names specified in Client Node Descriptor above Data_Type Specify memory area type Detector Module Detector_Trouble Module_Trouble Panel Panel_Trouble Bell_Trouble Node_Trouble Address Starting address of block As per Data_type Detector Module 1...

Page 11: ...fset Function Node_Name Loop Data_Type Address Length Capture Node Events SMD_N2_Troubles DA_SYS_N2 0 Passive NODE2 Node_Trouble 1 508 SMD_N2_PANEL DA_N2_PANEL 0 Passive NODE2 Panel 1 1056 SMD_N2_PANEL_T DA_N2_PANEL_T 0 Passive NODE2 Panel_Trouble 1 96 SMD_N2_BELL_T DA_N2_BELL_T 0 Passive NODE2 Bell_Trouble 1 4 Capture Loop 1 events SMD_N2L01D DA_N2L01D 0 Passive NODE2 1 Detector 1 1749 SMD_N2L01D...

Page 12: ...logies 1991 Tarob Court Milpitas California 95035 USA Web www fieldserver com Tel 408 262 2299 Fax 408 262 2269 Toll Free 888 509 1970 email support fieldserver com 5 CONFIGURING THE FIELDSERVER AS A NOTIFIER NCA2 NFS2 3030 SERVER This driver cannot be configured as a Server ...

Page 13: ... states 1 0 SECURITY ALARM CLEARED SECURITY ALARM states 1 0 CRITICAL PROCESS CRITICAL PROCESS states 1 0 SUPERVISORY CLEARED SUPERVISORY states 1 0 TROUBLE FAULT CLEARED TROUBLE FAULT States counter DISABLED CLEARED DISABLED states 1 0 PREALARM CLEARED PREALARM states 1 0 ACTIVE CLEARED ACTIVE states 1 0 ON OFF OFF states 1 0 SYSTEM NORMAL Resets all addresses in all memory areas but only if data...

Page 14: ...D 5 276 STYLE 6 NEG LOOP 10 23 COMM FAULT LOOP INTERFACE BOARD 6 277 STYLE 6 POS LOOP 1 24 COMM FAULT LOOP INTERFACE BOARD 7 278 STYLE 6 POS LOOP 2 25 COMM FAULT LOOP INTERFACE BOARD 8 279 STYLE 6 POS LOOP 3 26 COMM FAULT LOOP INTERFACE BOARD 9 280 STYLE 6 POS LOOP 4 27 COMM FAULT LOOP INTERFACE BOARD 10 281 STYLE 6 POS LOOP 5 28 CATASTROPHIC ISIB COMMUNICATIONS FAULT 282 STYLE 6 POS LOOP 6 29 MEM...

Page 15: ...BOVE LIMIT ON LOOP 10 335 REMOTE DISPLAY 2 TROUBLE 82 TOO MANY DEVICES ON LOOP 1 336 REMOTE DISPLAY 3 TROUBLE 83 TOO MANY DEVICES ON LOOP 2 337 REMOTE DISPLAY 4 TROUBLE 84 TOO MANY DEVICES ON LOOP 3 338 REMOTE DISPLAY 5 TROUBLE 85 TOO MANY DEVICES ON LOOP 4 339 REMOTE DISPLAY 6 TROUBLE 86 TOO MANY DEVICES ON LOOP 5 340 REMOTE DISPLAY 7 TROUBLE 87 TOO MANY DEVICES ON LOOP 6 341 REMOTE DISPLAY 8 TRO...

Page 16: ...NNUN 6 NO ANSWER 138 LIB 8 NIB COMMUNICATION ERROR 392 ANNUN 7 NO ANSWER 139 LIB 9 COMMUNICATION ERROR 393 ANNUN 8 NO ANSWER 140 LIB 10 NIB COMMUNICATION ERROR 394 ANNUN 9 NO ANSWER 141 LIB 1 NIB M S PROGRAMMING ERROR 395 ANNUN 10 NO ANSWER 142 LIB 2 NIB M S PROGRAMMING ERROR 396 ANNUN 11 NO ANSWER 143 LIB 3 NIB M S PROGRAMMING ERROR 397 ANNUN 12 NO ANSWER 144 LIB 4 NIB M S PROGRAMMING ERROR 398 A...

Page 17: ...R SECONDARY STATUS 450 UDACT NO ANSWER 197 LINK PROTECTOR PRIMARY NOT PRESENT 451 MASTER BOX NO ANSWER 198 EVENT BUFFER 80 FULL 452 DAA NO ANSWER 199 EBI STATUS 453 NO ANSWER 200 SOFTWARE MISMATCH 454 NETWORK FAILURE 201 NO POWER SUPPLY INST 455 WORKSTATION FAN FAILURE 202 TEST PROGRAM UPDATE 456 UPS FAILURE 203 HISTORY 80 FULL 457 NCM COMM FAILURE 204 FLASH IMAGE ERROR 458 NODE COMMUNICATIONS FAI...

Page 18: ...L PORT B 244 DVC COMM LOSS 498 STYLE 4 SHORT A L1 245 A C POWER LOSS BACK UP ACTIVATED 499 STYLE 4 SHORT B L1 246 BUZZER OFF LINE 500 STYLE 4 SHORT A L2 247 PANEL DOOR OPEN 501 STYLE 4 SHORT B L2 248 OFF NETWORK 502 STYLE 4 SHORT A L3 249 INSTALL ERROR 503 STYLE 4 SHORT B L3 250 OR AUDIO TELEPHON 504 STYLE 4 SHORT A L4 251 EXPANDER MODULES 505 STYLE 4 SHORT B L4 252 MANUAL CONTROL 506 STYLE 4 SHOR...

Page 19: ...NCA 2 EIA 232 Protocol Data Formats 53219 Rev A 1 3 2008 Any changes or additions by Notifier will not be reflected in this driver unless specifically revised This driver will not record information about zone status that is incorporated with point status messages There can only be one panel connected to any given FieldServer port This driver records data as presented to the printer CRT port by th...

Page 20: ...e ground potential problems Appendix B 2 Networking Tips By default FieldServer does not take any action on receiving a SYSTEM RESET Normally when a Node initiates SYSTEM RESET by pressing the RESET button on the Panel the panel sends an individual CLEAR message for every point it clears in its memory area The FieldServer therefore waits for the CLEAR message to clear a specific bit in its memory ...

Page 21: ... d Node u Loop d Data_Type s Address d The FieldServer got a recognized message on this particular port Node loop Address_Type and Address but did not find a defined Map Descriptor To capture this data add a new Map Descriptor with the required parameters 2 Err Reset Normal queue d full on MD s This driver keeps track of all non zero memory locations per Map Descriptor When the track queue is full...

Page 22: ...n 0 This occurs due to poor synchronization between the FieldServer and the Notifier panel or because a problem existed before connection 3 It will rectify itself upon System Normal message Check the configuration file to identify the address and memory area type mapped to this offset and the Data Array which is causing the error 3 All Data Arrays on the FieldServer are initialized to zero on rebo...

Reviews: