Fieldmann FZI 4018 BI User Manual Download Page 7

EN

INVERTER GENERATOR

USER MANUAL

7

Control panel functions

3.  CONTROL PANEL FUNCTIONS 

ON/OFF START SWITCH AND CHOKE

Start Switch “OFF”
When the Start Switch is in the “OFF” position the fuel valve is 
switched off and the engine will not run.

Start Switch “CHOKE”
When the Start Switch is in the “CHOKE” position the fuel valve is 
switched on and the engine can be started.

Start Switch “RUN”
When the Start Switch is in the “RUN” position the fuel valve is 
switched on and the engine can run.

 

Note:

 

The Choke is not required to start a warm engine

OIL WARNING INDICATOR LIGHT

When the oil falls below the minimum level, the oil warning 
indicator light comes on and the engine stops automatically. The 
engine will not start until the proper amount of oil is in the crank 
case.

 

Note:

 

If the oil warning indicator light does not come on 

and the engine stalls, turn the Start Switch to “RUN” and pull the 
recoil starter.

ENGINE OVERLOAD INDICATOR LIGHT

If the engine overload indicator light comes on, the generator 
s wattage / amperage capacity has been exceeded by 
connected electrical devices or by a power surge. When this 
occurs, the green AC Pilot Indicator Light will go off. The engine 
will continue to run, (but the red Engine Overload Indicator Light 
will stay on and power will no longer be supplied to connected 
electronic devices.)

HOW TO CORRECT

1.  Disconnect any electronic devices then stop the engine.
2.  Reduce the total wattage of connected electronic devices until 

it is within the generator’s rated output.

3.  Inspect the Air Inlet and Control Panel for any blockage. 

Remove blockage if found.

4. Restart Engine.

 

AC Pilot 

Indicator light

Overload 

Indicator light

Oil Warning 

Indicator light

Summary of Contents for FZI 4018 BI

Page 1: ...FZI 4018 BI...

Page 2: ...EN 2 FZI 4018 BI English 3 26 e tina 27 50 Sloven ina 51 74 Magyarul 75 98 Polski 99 122...

Page 3: ...al 9 4 ASSEMBLY 10 Connecting Generator to an Electrical System 10 Adding Fuel 10 Adding Checking Engine Oil 11 5 OPERATION 12 Grounding the Generator 12 Standard Atmospheric Conditions 12 How to Star...

Page 4: ...frameworks and other electric appliances Position the generator on at surface to prevent overturning or fuel spilling Keep your children and pets away from the work area Don t handle with wet hands D...

Page 5: ...ent to moisture rain or snow Don t operate with wet hands of feet Petrol and its vapours are combustible and explosive Prior to replenishing the fuel turn the engine off and let it cool down for at le...

Page 6: ...el tank cap bleeding valve G Fuel tank cap H Start up handle CONTROL PANEL I Control panel J Oil warning indicator K Overloading indicator L Main alternating voltage indicator M Three pole switch ACTI...

Page 7: ...oil is in the crank case Note If the oil warning indicator light does not come on and the engine stalls turn the Start Switch to RUN and pull the recoil starter ENGINE OVERLOAD INDICATOR LIGHT If the...

Page 8: ...devices to the generator that exceed the generator s rated output If the DC Circuit Breaker turns off reduce the load of connected electronic devices until the load is within the speci ed rated outpu...

Page 9: ...R VENT The fuel cap is equipped with an air vent to stop fuel from owing to the carburetor The Air Vent must be in the ON position to allow fuel to ow so that the engine can run Turn the Air Vent to t...

Page 10: ...or highly conductive area such as metal decking or steel work Never plug electronic devices into generator having frayed worn or bare wires Never touch bare wires or make contact with receptacles Neve...

Page 11: ...he speci ed amount of 4 Cycle engine oil SAE 10W 30 to empty reservoir until or oil reaches the outer edge of the oil ll hole crankcase dipstick hole Be sure to replace dipstick and securely tighten b...

Page 12: ...uel cap Air Vent to the ON position Turn the 3 in 1 Start Switch to CHOKE Pull recoil handle starter cord slowly until resistance is felt then pull rapidly Let engine run for several seconds and then...

Page 13: ...ICES 1 Before Starting generator Make sure the generator is grounded see page 10 for instructions Make sure the attached load is within the generator rated output and the receptacle s rated current Ma...

Page 14: ...ating or fueling this generator Battery electrolyte contains sulfuric acid Avoid contact with skin eyes and clothing Always wear eye protection when charging battery If battery add contacts skin ush w...

Page 15: ...300 900 Toaster 2 slice 1000 1600 Coffee Maker 1500 1500 Electric Range 1 element 1500 1500 Dishwasher 1500 3000 Laundry Room Iron 1200 1200 Washing Machine 1150 3400 Gas Clothes Dryer 700 2500 Bathro...

Page 16: ...efore starting the engine perform the following pre operation steps Check the level of the engine oil and the fuel tank level Check for any leakage Check fuel hose for cracks or damage Replace if nece...

Page 17: ...nd clean carbon deposits off the electrode with a wire brush Check the electrode gap and slowly adjust to 0 6 0 7mm 0 024 0 028 in if necessary Reinstall spark plug and tighten to Torque 20 0Nm 14 8ft...

Page 18: ...rator to collect used oil Allow oil to drain completely Return generator to a level surface Carefully add 4 Cycle engine oil SAE 10W 30 to empty reservoir until oil reaches the outer edge of the oil l...

Page 19: ...tion is made AIR FILTER A dirty air lter will reduce the life span of the engine make it dif cult to start the engine and reduce the unit s performance Replace with new lter annually To clean remove t...

Page 20: ...cool before touching FUEL TANK FILTER To clean remove fuel cap and lter Clean lter with gasoline Wipe the lter with a clean rag Install lter Install fuel cap FUEL FILTER To clean remove screws remove...

Page 21: ...s to prevent freezing and use aprotective cover to protect from dust The generator must be Shipped Run and Stored in the upright position as seen in this image WARNING Contact with a hot engine or exh...

Page 22: ...engine and let it run until it stops and all remaining fuel is consumed Do not connect electronic devices to generator during this process Remove outer casing screws then remove outer casing Drain fu...

Page 23: ...thly I The three position switch is set to OFF 2 Blocked air lter 3 Clogged fuel lter 4 The fuel has run out or is poor quality 5 The spark plug cable is disconnected from the spark plug 6 Poor qualit...

Page 24: ...hours Engine Oil Capacity 350ml 11 8oz Spark Plug Model No A7TC A7RT Starter Type Recoil Starter Generator Set Length Width Height mm 520X290X440 mm Net Weight 18 kg Pulsar Products continually seeks...

Page 25: ...for waste in your municipality The appliance and its accessories are manufactured from various materials e g metal and plastic Take damaged parts to a recycling centre Inquire at the relevant governm...

Page 26: ...is issued under the sole responsibility of the manufacturer The object of the declaration described above is in conformity with the relevant Union harmonization legislation Directive MD 2006 42 EC Di...

Page 27: ......

Page 28: ...i F 8 JFQ TDVTi a X FJFTN D8 JF F D8 XaD9 DVTi DvB V s DlB XvMF V JF F D8 XvMF V GQ V D F FMD w8 D QJNgXf D 9D T g 8 JFV 8T8 XvNF V NFaJFM Q DgXF FB D JFV 9T8 Q J TDvB9 JMgXD B8 JN J8QB8 X F D aDgB B8...

Page 29: ...nyolc napon bel l kell a fogyaszt r sz re visszat r teni Ha a term k kijav t s ra a kijav t si ig ny k zl s t l sz m tott 30 napig nem ker l sor a fogyaszt elt r rendelkez se hi ny ban a term ket a 3...

Page 30: ...y bejelent s nek id pontja Jav t sra tv tel id pontja Hiba oka Jav t s m dja A term k fogyaszt r sz re val visszaad s nak id pontja A j t ll s kijav t s id tartam val meghosszabb tott j hat rideje Sze...

Page 31: ......

Page 32: ......

Reviews: