FZI 4018 BI
Operation
5. OPERATION
GROUNDING THE GENERATOR
To avoid electrocution, this generator must be properly grounded prior to use. For instructions see Control Panel
Functions pg. 10.
STANDARD ATMOSPHERIC CONDITIONS
Ambient Temperature: 77ºF (25ºC)
Barometric Pressure: 100kPa
Relative Humidity: 30%
Generator output will vary due to changes in temperature, altitude, and humidity. If the temperature, humidity,
or altitude are higher than standard atmospheric conditions, the generator’s output will be reduced. The load
attached to the generator must therefore be reduced.
HOW TO START ENGINE
Place generator on a level surface. All electrical loads
MUST
be disconnected from generator.
Turn the Economy switch to “OFF”
Turn the fuel cap Air Vent to the “ON” position.
Turn the 3 in 1 Start Switch to “CHOKE”
Pull recoil handle (starter cord) slowly until resistance is felt, then pull rapidly.
Let engine run for several seconds and then gradually, as engine warms up, turn the 3 in 1 Start Switch to the
“RUN” position.
WARNING!
Pull cord recoils rapidly and pulls arm towards engine faster than you can let go which
could result in injury.
To avoid recoil, pull starter cord slowly until resistance is felt, then pull rapidly.
Note:
To start the generator with the Economy switch in the “ON” position
Disconnect all electrical loads from generator.
If ambient temperature is below 32ºF (0ºC) allow about 3 minutes for the engine to warm up.
The Economy is in “ON” position, the unit returns to normal operation after the above warm up time.
Economy switch must be turned to the “OFF” position when using electronic devices that require a large
starting current, such as a compressor.