Fieldmann FZI 4018 BI User Manual Download Page 19

EN

INVERTER GENERATOR

USER MANUAL

19

Maintenance

HIGH ALTITUDE OPERATION

At high altitude, the standard carburetor air/fuel mixture will be too rich. Performance will decrease, and fuel 
consumption will increase. A very rich mixture will also foul the spark plug and cause hard starting.
Operation at an altitude that differs from that at which this engine was certifi ed, for extended periods of time, 
may increase emissions. High altitude performance can be improved by specifi c modifi cations to the carburetor. 
If you always operate your generator at altitudes above 5,000 feet (1,500 meters), have your dealer perform 
this carburetor modifi cation. This engine, when operated at high altitude with the carburetor modifi cations for 
high altitude use, will meet each emission standard throughout its useful life. Even with carburetor modifi cation, 
engine horsepower will decrease about 3.5% for each 1,000-foot (300-meter) increase in altitude. The effect of 
altitude on horsepower will be greater than this if no carburetor modifi cation is made.

AIR FILTER

A dirty air fi lter will reduce the life span of the engine, make it diffi cult to 
start the engine, and reduce the unit’s performance. Replace with new fi lter 
annually.

  To clean, remove the screws then remove outer casing.
  Remove the screws then remove air fi lter cover.
  Remove the foam element.
  Wash the foam element in solvent and let dry.
  Pour a small amount of oil on the foam element then squeeze out, but do 

not wring out, excess oil. Foam element should be damp, but not dripping.

  Reinsert the foam element into the air fi lter case.

 CAUTION!

Do not run the generator without reinstalling the foam element or excessive piston and 
cylinder wear may result.

CHECKING MUFFLER AND SPARK ARRESTER

  Inspect muffl er for cracks, corrosion, or other damage.
  Remove screws, then remove the muffl er cover as shown.
  Loosen bolt, then remove muffl er cap, muffl er screen, and spark arrester.
  Check the muffl er screen and spark arrester for carbon deposits. Remove carbon deposits with a wire brush.
  Check the muffl er screen and spark arrester for damage. If damaged replace with PULSAR replacement parts 

specifi cally designed for this unit.

  Install the spark arrester. Align the spark arrester projection with the hole in the muffl er pipe.

Summary of Contents for FZI 4018 BI

Page 1: ...FZI 4018 BI...

Page 2: ...EN 2 FZI 4018 BI English 3 26 e tina 27 50 Sloven ina 51 74 Magyarul 75 98 Polski 99 122...

Page 3: ...al 9 4 ASSEMBLY 10 Connecting Generator to an Electrical System 10 Adding Fuel 10 Adding Checking Engine Oil 11 5 OPERATION 12 Grounding the Generator 12 Standard Atmospheric Conditions 12 How to Star...

Page 4: ...frameworks and other electric appliances Position the generator on at surface to prevent overturning or fuel spilling Keep your children and pets away from the work area Don t handle with wet hands D...

Page 5: ...ent to moisture rain or snow Don t operate with wet hands of feet Petrol and its vapours are combustible and explosive Prior to replenishing the fuel turn the engine off and let it cool down for at le...

Page 6: ...el tank cap bleeding valve G Fuel tank cap H Start up handle CONTROL PANEL I Control panel J Oil warning indicator K Overloading indicator L Main alternating voltage indicator M Three pole switch ACTI...

Page 7: ...oil is in the crank case Note If the oil warning indicator light does not come on and the engine stalls turn the Start Switch to RUN and pull the recoil starter ENGINE OVERLOAD INDICATOR LIGHT If the...

Page 8: ...devices to the generator that exceed the generator s rated output If the DC Circuit Breaker turns off reduce the load of connected electronic devices until the load is within the speci ed rated outpu...

Page 9: ...R VENT The fuel cap is equipped with an air vent to stop fuel from owing to the carburetor The Air Vent must be in the ON position to allow fuel to ow so that the engine can run Turn the Air Vent to t...

Page 10: ...or highly conductive area such as metal decking or steel work Never plug electronic devices into generator having frayed worn or bare wires Never touch bare wires or make contact with receptacles Neve...

Page 11: ...he speci ed amount of 4 Cycle engine oil SAE 10W 30 to empty reservoir until or oil reaches the outer edge of the oil ll hole crankcase dipstick hole Be sure to replace dipstick and securely tighten b...

Page 12: ...uel cap Air Vent to the ON position Turn the 3 in 1 Start Switch to CHOKE Pull recoil handle starter cord slowly until resistance is felt then pull rapidly Let engine run for several seconds and then...

Page 13: ...ICES 1 Before Starting generator Make sure the generator is grounded see page 10 for instructions Make sure the attached load is within the generator rated output and the receptacle s rated current Ma...

Page 14: ...ating or fueling this generator Battery electrolyte contains sulfuric acid Avoid contact with skin eyes and clothing Always wear eye protection when charging battery If battery add contacts skin ush w...

Page 15: ...300 900 Toaster 2 slice 1000 1600 Coffee Maker 1500 1500 Electric Range 1 element 1500 1500 Dishwasher 1500 3000 Laundry Room Iron 1200 1200 Washing Machine 1150 3400 Gas Clothes Dryer 700 2500 Bathro...

Page 16: ...efore starting the engine perform the following pre operation steps Check the level of the engine oil and the fuel tank level Check for any leakage Check fuel hose for cracks or damage Replace if nece...

Page 17: ...nd clean carbon deposits off the electrode with a wire brush Check the electrode gap and slowly adjust to 0 6 0 7mm 0 024 0 028 in if necessary Reinstall spark plug and tighten to Torque 20 0Nm 14 8ft...

Page 18: ...rator to collect used oil Allow oil to drain completely Return generator to a level surface Carefully add 4 Cycle engine oil SAE 10W 30 to empty reservoir until oil reaches the outer edge of the oil l...

Page 19: ...tion is made AIR FILTER A dirty air lter will reduce the life span of the engine make it dif cult to start the engine and reduce the unit s performance Replace with new lter annually To clean remove t...

Page 20: ...cool before touching FUEL TANK FILTER To clean remove fuel cap and lter Clean lter with gasoline Wipe the lter with a clean rag Install lter Install fuel cap FUEL FILTER To clean remove screws remove...

Page 21: ...s to prevent freezing and use aprotective cover to protect from dust The generator must be Shipped Run and Stored in the upright position as seen in this image WARNING Contact with a hot engine or exh...

Page 22: ...engine and let it run until it stops and all remaining fuel is consumed Do not connect electronic devices to generator during this process Remove outer casing screws then remove outer casing Drain fu...

Page 23: ...thly I The three position switch is set to OFF 2 Blocked air lter 3 Clogged fuel lter 4 The fuel has run out or is poor quality 5 The spark plug cable is disconnected from the spark plug 6 Poor qualit...

Page 24: ...hours Engine Oil Capacity 350ml 11 8oz Spark Plug Model No A7TC A7RT Starter Type Recoil Starter Generator Set Length Width Height mm 520X290X440 mm Net Weight 18 kg Pulsar Products continually seeks...

Page 25: ...for waste in your municipality The appliance and its accessories are manufactured from various materials e g metal and plastic Take damaged parts to a recycling centre Inquire at the relevant governm...

Page 26: ...is issued under the sole responsibility of the manufacturer The object of the declaration described above is in conformity with the relevant Union harmonization legislation Directive MD 2006 42 EC Di...

Page 27: ......

Page 28: ...i F 8 JFQ TDVTi a X FJFTN D8 JF F D8 XaD9 DVTi DvB V s DlB XvMF V JF F D8 XvMF V GQ V D F FMD w8 D QJNgXf D 9D T g 8 JFV 8T8 XvNF V NFaJFM Q DgXF FB D JFV 9T8 Q J TDvB9 JMgXD B8 JN J8QB8 X F D aDgB B8...

Page 29: ...nyolc napon bel l kell a fogyaszt r sz re visszat r teni Ha a term k kijav t s ra a kijav t si ig ny k zl s t l sz m tott 30 napig nem ker l sor a fogyaszt elt r rendelkez se hi ny ban a term ket a 3...

Page 30: ...y bejelent s nek id pontja Jav t sra tv tel id pontja Hiba oka Jav t s m dja A term k fogyaszt r sz re val visszaad s nak id pontja A j t ll s kijav t s id tartam val meghosszabb tott j hat rideje Sze...

Page 31: ......

Page 32: ......

Reviews: