When...
Causes Repairs
The pump does not start
No power supply
Check the power supply
The fl oat does not switch
Move the fl oat to a higher position
Not fl owing
The suction sieve is clogged
Flush out the suction sieve with a current
of water
The pressure hose is bent
Straighten the hose
The pump does not turn off
The fl oat cannot fall lower
Place the pump correctly on the fl oor of
the tank
Insuffi cient fl ow
The suction sieve is clogged
Clean the suction sieve
Lowered pump capacity due to dirty and
silted water
Clean the pump and fl ush the hose with
clean water
The pump turns off after a short
time
The temperature fuse stops the pump due
to dirty water
Disconnect the power plug. Clean the
pump and the pumping pit
The water is too hot. The temperature fuse
stops the pump
Check that the maximum water
temperature of 35 °C is not exceeded
NOTE:
Not covered by warranty:
Damage to the rotating mechanical gasket caused by running the pump empty, or by foreign objects in the
water
Blocking of the running wheel by foreign objects
Damage during transport
Damage caused by unprofessional alterations by persons