INSTALLATION 

M

OUNTING 

J

UNCTION 

B

OX

 

The junction box can be mounted at the venter or remotely mounted away 
from the venter. (See Figure 1 & Figure 2) 

1.  Remove one of the knockouts from the side of the junction box where 

the pressure switch is mounted. Install the flexible conduit connector 
onto the CK-61 Junction Box and secure with fastening nut. If remote 
mounting the CK-61 Junction Box, mount the flexible conduit 
connector onto a 2" x 4" installer supplied junction box. 

2.  Fasten the flexible conduit from the SWG Venter into the conduit 

connector. Mount the CK-61 Junction box or installer supplied junction 
box onto the wall or floor joist without straining the flexible conduit. 
Fasten the CK- 61 Junction Box through the four dimpled locations on 
the base of the box. (See Figure 3) 

O

IL 

F

IRED 

S

ECONDARY 

S

AFETY 

S

WITCH 

(WMO-1) 

Installation of a SECONDARY SAFETY SWITCH (WMO-1) is 
recommended for detecting flue gas spillage from a blocked flue system 
and/or inadequate draft. 

1.  Pierce a 5/8" dia. hole into the vent pipe near the appliance outlet. 

Remove one of the securing nuts from the shaft of the safety switch. 
(See Figure 4) Tighten the other securing nut onto the pipe as far as 
possible.  

2.  Insert the threaded pipe end into the pierced hole, then install the 

securing nut, which was removed in Step 1, and tighten securely (See 
Figure 5) 

3.  Wire safety switch in series into one side of the burner circuit. Refer to 

Unit Wiring Instructions. 

CAUTION:

 

If for any reason the system has shut down during 

operation, the cause of the system failure should be investigated 
and corrected before resetting the safety switch and restarting the 
system.

 

P

RESSURE 

S

WITCH 

S

ENSING 

T

UBE 

I

NSTALLATION

 

1.  Attach the 1/4 inch tubing connector to the pressure tube on the SWG 

Venter. (See Figure 3) 

2.  Connect the supplied 1/4" aluminum  tubing to the tubing connector. 

Route the tubing to the CK- 61 Junction Box and connect the tubing to 
the pressure switch. When routing the tubing avoid kinking the tubing by 
bending the tubing too sharply. 

3.  For remote mounted CK-61 Junction Box, use a 1/4" OD copper, 

aluminum or plastic tubing and route the tubing to avoid contact with any 
heat source. 

Refer to the SWG Venter installation instructions for setting system airflow.

 