background image

MCM1000S/L GBE module 

 

9

 

 

– Fiber Optic Connection 

The MCM1000S/L modules are equipped with two SC-type connectors. 
Do  not  remove  the  protective  covers  on  the  fiber  connectors  until  you  are  ready  to 
connect  the  fiber  optic  cables.  Power  should  be  connected  (install  the  module  into  a 
MetroStar  slot)  before  attaching  the  fiber  optic  cables.  When  dealing  with  fiber  optic 
cables, it is essential to ensure that the Tx at one end of the link is connected to the Rx 
at  the  other  end  of  the  link.  Some  duplex  fiber  optic  cables  are  color  coded  to  help 
monitor  the  direction  of  data  transmission.  If  the  fibers  are  not  coded,  special  attention 
must be paid to ensure a proper connection.

 If your distance is shorter than specified in 

the table below (see next page) for your model or should you wish to perform a local test, 
insert first in line (both receive and transmit) appropriate attenuators (5db should suffice). 
 

 

CAUTION 

Radiation emitted from a fiber optic connector may be 
hazardous to human vision. Therefore, the following rules 
must be strictly observed. 

 

All single-mode (SM) models are CLASS I LASER PRODUCTS 
and must be handled with special care 
When not in use, keep the fiber optic connector closed using 
its protective cover

The fiber optic transmitter is a CLASS 1 Laser product that 
may endanger your eyes 

 

 

 

Never stare directly into the fiber optic connector of a powered 
device or into the end of a fiber connected to it. 
Do not look directly into the fiber optic cables or transmitter 

 

Laser Safety  

 

The emissions produced by the end products described in this guide are under Class 1 emission 

level according to IEC 60825-1 and the FDA 21 CFR 1040.10 and 1040.1. These products shall not 
be installed in an optical network handling above Class 1 level. 

 

Summary of Contents for MCM1000L-LX1-2

Page 1: ...tender 1000Base SX LX to 1000Base LX User and Installation Guide Version 2 4 FibroLAN Ltd 2 Carmel St P O Box 544 Yokneam Illit 20692 ISRAEL Tel 972 4 9591717 Fax 972 4 9591718 E mail support fibrolan...

Page 2: ...to take whatever measures may be necessary to correct the interference Changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operat...

Page 3: ...ooting page 18 Specifications page 19 Module default settings page 19 Warranty Limitation page 20 Thank you for purchasing the MCM1000S L GBE Module Converter Extender from FibroLAN We hope that this...

Page 4: ...nced diagnostics Like other MetroStar modules the MCM1000S L is fully SNMP managed All MetroStar modules are hot swappable A special LED indicates that the module is well inserted in its slot and aliv...

Page 5: ...mode 1310nm 10Km to 1000LX single mode 1550nm DFB Extender module 80Km 2 Duplex SC MA MCM1000L LX3 3 1000LX single mode 1550nmDFBTx 1550nmRx 40Km to 1000LX single mode 1550nmDFBTx 1550nmRx Extender m...

Page 6: ...MetroStar SNMP management module MMM 01or MMM 04 for standalone MetroStar The PMM module is normally installed in slot 4 in unmanaged MetroStar System optional module When the MetroStar chassis is no...

Page 7: ...t from port 1 S4 UP LST ON when data is not transmitted at the same time Port 2 LST lit red implies that an idle signal is sent from port 2 S3 UP LST ON when data is not transmitted at the same time M...

Page 8: ...t lit remove the module and re insert Is problem persists troubleshoot by inserting same module in a different slot and or another module in the suspected slot Fasten both self clinching screws using...

Page 9: ...ld you wish to perform a local test insert first in line both receive and transmit appropriate attenuators 5db should suffice CAUTION Radiation emitted from a fiber optic connector may be hazardous to...

Page 10: ...0 2 10 40 MCM1000S LX4 9 5 19 850 0 24 1550 DFB 0 2 25 80 MCM1000L LX1 2 11 20 1310 7 20 1310 0 10 10 20 MCM1000L LX1 3 11 20 1310 5 23 1550 DFB 0 10 10 40 MCM1000L LX1 4 11 20 1310 0 24 1550 DFB 0 1...

Page 11: ...h handshake within that time it concludes that the opposite end device is not MA enabled subsequently it bypasses its special functions and operates like a standard straight forward access device Ther...

Page 12: ...sor a more powerful processor is used Operating System using a newer OS provides the foundation for a more flexible system with extended capabilities Features and Characteristics Linux operating syste...

Page 13: ...to port 1 LB Loop back LST Link Segmentation Test Default DIP switches set up S1 S2 in Down position LB disabled S3 S4 in UP position LST ON Test Mode Up Down TP F O Port Setup LB LST S1 S2 S3 S4 TP...

Page 14: ...verride the setting of the DIP switches in GSM1000 MA and the default values are established by the MMM 01 SNMP management module installed in the MetroStar system Therefore you have to setup the DIP...

Page 15: ...ion generates an idle signal to be transmitted from MCM1000S to Network Device A turning On the Link at Network Device A This indicates that the link segment between the MCM1000S module and Network De...

Page 16: ...te device CPE via MA It should be noted that if the F O link of port 1 of the MCM1000S L module normally connected to a switch router port has failed the SLE will cut off the TP port or F O link of th...

Page 17: ...any SNMP management station running popular management platforms e g FibroLAN s MetroView HP OpenView SNMPc etc When the remote MA enabled devices are connected through their F O link to a remote Acce...

Page 18: ...in manufacturer s specifications Verify that the dB loss of the fiber cable you are connecting to plus additional losses connectors losses normally 1 5dB per mated pair Splice loss 0 3db max and 3db l...

Page 19: ...0 edition 1000Base SX 1000Base LX IEEE802 3z Conversion Method Digital Conversion Management SNMP management via MetroStar management module MMM 01 F O ports Port 2 Duplex SC S M fiber 1310 1550nm 100...

Page 20: ...the reseller from which you have purchased the device however you may refer directly to FibroLAN Ltd to claim the warranty providing reasonable proof that the reseller ceased operation and or unreaso...

Reviews: