background image

MCM1000S/L GBE module 

 

 

06

 

12 

 SLE (Subscriber Link Emulation) 

If  the  remote  device  is  a  FibroLAN  MA™  device  (GSM1000/MA  or  GSM1010/MA)  and 
the  MetroStar  system  is  managed,  the  most  powerful  SLE  feature  may  be  deployed  to 
further enhancing the network resilience. 

 

 

SLE Operations 

 

FibroLAN’s 

S

ubscriber 

L

ink 

E

mulation 

virtually  emulates  the  subscriber’s  device  or 

network  connected  to  the  TP  (or  F/O)  port  of  the  remote  device  (GSM1010/MA  or 
GSM1000/MA) onto the F/O link of the MCM1000S/L port module (connected usually to 
a  switch/router).  When  activated  (

controllable

 

via  the  management  system  only

)  it 

senses the loss of the TP link (or F/O link) connected to the remote MA device, notifies 
the MCM1000S/L and cuts off the port 1 F/O link of the  MCM1000S module, alerting in 
real  time  the  switch/router  of  the  subscriber’s  failure.  All  this  is  performed  without 
disrupting the main F/O link, thus ensuring on-going control of the remote device (CPE) 
via MA. 

It should be noted that if the F/O link of port 1 of the MCM1000S/L module 
(normally connected to a switch/router port) has failed, the SLE will cut-off the TP 
port (or F/O) link of the remote GSM1000/MA device, providing in this manner an 
optimal bidirectional safe operation. 

 Thus SLE has in effect two modes of operation:  

 

Downstream  SLE  mode: 

link failure of the MCM1000S/L  module  F/O  input  port 

(port 1) will cause the disconnect of the link input port of the remote GSM1000/MA  
device  

 

Upstream  SLE  mode:  remote  MA  device  link  input  port  failure  will  cause  the 
disconnect of the MCM1000S module link port 

 

 
                                                                                                                                                                                                                                                                                                                       

   

Again  it  must  be  emphasized  that  this  extensive  set  of  features  is  obtained 

only  if  MA 

enabled devices are installed at both ends of the link. 

Note: When the SLE mechanism is enabled, it will override the LST mechanism.

 

During normal network operation, it is recommended to activate the SLE mechanism. 
(Enable Downstream and Upstream modes through the management). 
Use and stay in the LST ON (TEST mode) if link failure alertness is not needed. 
In this case a link failure is indicated by its LED link OFF. 

Summary of Contents for MCM1000L-LX1-2

Page 1: ...tender 1000Base SX LX to 1000Base LX User and Installation Guide Version 2 4 FibroLAN Ltd 2 Carmel St P O Box 544 Yokneam Illit 20692 ISRAEL Tel 972 4 9591717 Fax 972 4 9591718 E mail support fibrolan...

Page 2: ...to take whatever measures may be necessary to correct the interference Changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operat...

Page 3: ...ooting page 18 Specifications page 19 Module default settings page 19 Warranty Limitation page 20 Thank you for purchasing the MCM1000S L GBE Module Converter Extender from FibroLAN We hope that this...

Page 4: ...nced diagnostics Like other MetroStar modules the MCM1000S L is fully SNMP managed All MetroStar modules are hot swappable A special LED indicates that the module is well inserted in its slot and aliv...

Page 5: ...mode 1310nm 10Km to 1000LX single mode 1550nm DFB Extender module 80Km 2 Duplex SC MA MCM1000L LX3 3 1000LX single mode 1550nmDFBTx 1550nmRx 40Km to 1000LX single mode 1550nmDFBTx 1550nmRx Extender m...

Page 6: ...MetroStar SNMP management module MMM 01or MMM 04 for standalone MetroStar The PMM module is normally installed in slot 4 in unmanaged MetroStar System optional module When the MetroStar chassis is no...

Page 7: ...t from port 1 S4 UP LST ON when data is not transmitted at the same time Port 2 LST lit red implies that an idle signal is sent from port 2 S3 UP LST ON when data is not transmitted at the same time M...

Page 8: ...t lit remove the module and re insert Is problem persists troubleshoot by inserting same module in a different slot and or another module in the suspected slot Fasten both self clinching screws using...

Page 9: ...ld you wish to perform a local test insert first in line both receive and transmit appropriate attenuators 5db should suffice CAUTION Radiation emitted from a fiber optic connector may be hazardous to...

Page 10: ...0 2 10 40 MCM1000S LX4 9 5 19 850 0 24 1550 DFB 0 2 25 80 MCM1000L LX1 2 11 20 1310 7 20 1310 0 10 10 20 MCM1000L LX1 3 11 20 1310 5 23 1550 DFB 0 10 10 40 MCM1000L LX1 4 11 20 1310 0 24 1550 DFB 0 1...

Page 11: ...h handshake within that time it concludes that the opposite end device is not MA enabled subsequently it bypasses its special functions and operates like a standard straight forward access device Ther...

Page 12: ...sor a more powerful processor is used Operating System using a newer OS provides the foundation for a more flexible system with extended capabilities Features and Characteristics Linux operating syste...

Page 13: ...to port 1 LB Loop back LST Link Segmentation Test Default DIP switches set up S1 S2 in Down position LB disabled S3 S4 in UP position LST ON Test Mode Up Down TP F O Port Setup LB LST S1 S2 S3 S4 TP...

Page 14: ...verride the setting of the DIP switches in GSM1000 MA and the default values are established by the MMM 01 SNMP management module installed in the MetroStar system Therefore you have to setup the DIP...

Page 15: ...ion generates an idle signal to be transmitted from MCM1000S to Network Device A turning On the Link at Network Device A This indicates that the link segment between the MCM1000S module and Network De...

Page 16: ...te device CPE via MA It should be noted that if the F O link of port 1 of the MCM1000S L module normally connected to a switch router port has failed the SLE will cut off the TP port or F O link of th...

Page 17: ...any SNMP management station running popular management platforms e g FibroLAN s MetroView HP OpenView SNMPc etc When the remote MA enabled devices are connected through their F O link to a remote Acce...

Page 18: ...in manufacturer s specifications Verify that the dB loss of the fiber cable you are connecting to plus additional losses connectors losses normally 1 5dB per mated pair Splice loss 0 3db max and 3db l...

Page 19: ...0 edition 1000Base SX 1000Base LX IEEE802 3z Conversion Method Digital Conversion Management SNMP management via MetroStar management module MMM 01 F O ports Port 2 Duplex SC S M fiber 1310 1550nm 100...

Page 20: ...the reseller from which you have purchased the device however you may refer directly to FibroLAN Ltd to claim the warranty providing reasonable proof that the reseller ceased operation and or unreaso...

Reviews: