Information on ordered parts 

 

 

Connecting voltage /3-phase 

3x380VAC 

– 10% -3x10%  50/60Hz 

Recommended motor output 

0,12 

0,18 

0,25 

0,37 

0,55 

0,75 

1,1 

1,5 

2,2 

3,0 

4,0 

7,5 

MC07B Power in KW 

0,25 

0,37 

0,55 

0,75 

1,1 

1,5 

2,2 

5,5 

7,5 

11 

Item number /3-phase 
Frequency inverter             4-800-044- 

0059  0060  0061  0062  0063  0064  0065  0066  0067  0068  0069  0070 

Fuses in A 

10 

16 

25 

Connections 

Terminals 1,5 - 4 mm²  

Dimensions W x H x L 

55x185x163 

80x185x163 

80x274x163 

105x335 

x238 

130x
335x

229 

Weight in Kg 

1,3 

1,5 

2,1 

6,6 

Network chokes 

(to support the overvoltage protection. To limit 
the charging current with several parallel 
inverters on the input side) 

 

0007

 

 

Output chokes 

(To suppress the emission of interference 
from the unscreened motor cable) 

 

0008 

 

0021 

Others 

Larger performance versions on request! 

Options

 

 

 

Communication module      4-800-047- 

83N20-00073 

 

Interface reactor                    4-800-047- 

( RS232 into RS485 )

 

 
 

0003 

 

Interface reactor                    4-800-047- 

( USB2.0 into RS485 )

 

 

 

00027 

 

Communication module only if you 
need this module ever used for and 
possibly exist. 

 

External program memory 

 

 

 

 
Gateway Profibus, Device-Net, Interbus und CANopen Built-in inverter. Order on request! 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for Movitrac 07B

Page 1: ...Seite 1 von 17 FIBRO GmbH Bereich Rundschalttische D 74183 Weinsberg Postfach 1120 Tel 07134 73 0 Fax 07134 73 218 FIBRO RUNDSCHALTTISCHE Additional Instructions for Movitrac 07B Manual Frequency Inve...

Page 2: ...for Machinery Devices and Installations DIN EN 292 Sicherheit von Maschinen Ger ten und Anlagen Les normes nationales directives et sp cifications suivantes sont appliqu es The following National Stan...

Page 3: ...h ltnisse von dem f r die Sicherheit der Anlage Verantwortlichen berechtigt worden sind die jeweils erforderliche T tigkeiten auszuf hren und dabei m gliche Gefahren erkennen und vermeiden k nnen Defi...

Page 4: ...en Einlagern und Konservieren von Maschinen zur Fundamentpr fung zum Aufziehen von Kupplungen Aufstellen und Ausrichten von Maschinen Installationsma nahmen u v a sind Detailinformationen in der Betri...

Page 5: ...ren die durch Nichtbeachtung der in Frage kommenden Unfallverh tungs vorschriften entstehen For the above reasons we must point out that we will not accept any claims attributable to non adherence to...

Page 6: ...entiometer 9 Ordering list warnings 10 System overview Technicial data 12 Sequence diagram 13 Circuit diagram 3 phases 14 Circuit diagram Operating pendulum 15 EM Indexing table rotates after activati...

Page 7: ...e indexing table approaches the stall phase at minimum speed after a start and application of a signal at the input DI01 If there is no signal at DI04 S10 table top at stall and DI05 S12 motor off a r...

Page 8: ...e approaches the stall phase at minimum speed after a start and application of a signal at the input DI02 If there is no signal at DI04 S10 table top at stall and DI05 S12 motor off a rotary motion ca...

Page 9: ...e can be cycled to the selected direction via external actuation selection switch PLC outputs of the inputs DI01 or DI02 of the frequency inverter For the description of the software sequence refer to...

Page 10: ...ons Terminals 1 5 4 mm Dimensions W x H x L 55x185x163 80x185x163 80x274x163 105x335 x238 130x 335x 229 Weight in Kg 1 3 1 5 2 1 5 6 6 Network chokes to support the overvoltage protection To limit the...

Page 11: ...instructions of the rotary table is recommended prior to the commissioning of this unit We reserve all rights according to DIN 34 1 0 Subject to technical changes WARNING During the operation of elec...

Page 12: ...Bereich Rundschalttische D 74183 Weinsberg Postfach 1120 Tel 497134 73 0 Fax 497134 73 218 FIBRO RUNDSCHALTTISCHE Overview and Technical data Movitrac B Basic unit Operating Instructions Katalognumme...

Page 13: ...tzanleitung MC07B_GB doc gedruckt am 27 04 17 Seite 13 von 17 FIBRO GmbH Bereich Rundschalttische D 74183 Weinsberg Postfach 1120 Tel 497134 73 0 Fax 497134 73 218 FIBRO RUNDSCHALTTISCHE Sequence Diag...

Page 14: ...leitung MC07B_GB doc gedruckt am 27 04 17 Seite 14 von 17 FIBRO GmbH Bereich Rundschalttische D 74183 Weinsberg Postfach 1120 Tel 497134 73 0 Fax 497134 73 218 FIBRO RUNDSCHALTTISCHE Circuit Diagram 3...

Page 15: ...leitung MC07B_GB doc gedruckt am 27 04 17 Seite 15 von 17 FIBRO GmbH Bereich Rundschalttische D 74183 Weinsberg Postfach 1120 Tel 497134 73 0 Fax 497134 73 218 FIBRO RUNDSCHALTTISCHE Sequence Diagram...

Page 16: ...ng MC07B_GB doc gedruckt am 27 04 17 Seite 16 von 17 FIBRO GmbH Bereich Rundschalttische D 74183 Weinsberg Postfach 1120 Tel 497134 73 0 Fax 497134 73 218 FIBRO RUNDSCHALTTISCHE Circuit diagram Operat...

Page 17: ...uency inverter and if no red point lights at the lower right corner of the display the software programme does not start Software programme running Software programme not running Measures Option 1 Ins...

Reviews: