Connect the Phoenix™ power connector 
from the Power Harness at into its mating 
connector on the TD module in each 
position. 

 

 

8.

 

Install loaded TTM onto truss with 
appropriate Cheeseborough clamps. 

 

 

 

 

 

Reconfiguring Front Connectors 

1.

 

Unscrew and remove the upper positioning and 
holding brackets by removing the 7 retaining screws. 
Note that the screw that protrudes through the hinge 
bracket is slightly longer than the others. 
 
 
 
 
 
 
 

2.

 

Slightly loosen the 4 screws holding the bottom mounting plate to release the 
modular connector plates. 

 

 

3.

 

Replace and rearrange connector plates as needed, 
taking care to orient the chamfered edges towards 
the front of the enclosure. 

 

 

4.

 

Replace and the upper positioning bracket using two screws as 
shown. 

 

5.

 

Tighten down the screws which hold the lower holding bracket. 
 

 

6.

 

Replace the upper holding bracket and tighten all 
screws. 

 

 

Summary of Contents for TTM

Page 1: ...USER MANUAL 6 Position Truss Mount Enclosure for TD Series Modules with 16 Channel Modular Front Panel TTM...

Page 2: ...cable Repair must only be performed by trained personnel in accordance with the applicable regulations Installation Site Install the unit in a place where the following conditions are met The temperat...

Page 3: ...sal of Used Equipment Used equipment contains valuable raw materials as well as substances that must be disposed of professionally Please dispose of used equipment via an authorized specialist dealer...

Page 4: ...etting Started Initial Inspection Immediately upon receipt inspect the shipping container for damage The container should be retained until the shipment has been checked for completeness and the equip...

Page 5: ...Mounting Options Figure 1 Truss Mount using Cheeseborough Clamps not included Figure 2 Portable Drop Box...

Page 6: ...Down Six tie wrap bases are affixed within the enclosure to allow for clean management of cabling to the TD Series modules Tie wraps can be used to secure cable bundles against the rear and inside hi...

Page 7: ...nt I O connector plates Enclosure Latch The unit is securely closed screwing the two captive screws in the latch bracket into holes on the opposite enclosure half Hinge The reinforced aluminum hinges...

Page 8: ...de to the front of the Mounting Tray until the module stops 4 Repeat steps 1 3 until all desired modules are installed 5 Lower the Retention Bar flat on the tray so that it is on the rear power side o...

Page 9: ...s Note that the screw that protrudes through the hinge bracket is slightly longer than the others 2 Slightly loosen the 4 screws holding the bottom mounting plate to release the modular connector plat...

Page 10: ...Specifications Figure 5 TTM Dimensions Case Open 20 65 524 6 21 48 545 5 2 78 70 7 1 81 46 0 14 28 362 6...

Page 11: ...n 363 mm 11 4 in 290 mm 4 5 in 114 mm 6 5 lb 2 9 kg ELECTRICAL SPECIFICATIONS Min Typ Max Units Power Requirement Voltage Range 100 110 240 VAC Power Line Frequency 50 60 Hz Power Consumption 18 40 W...

Page 12: ...18040 412 Guilford Rd Annapolis Junction MD 20701 fiberplex com clients fiberplex com 301 604 0100 UMTTM 161011...

Reviews: