Figure 4 TTM Open, Bottom 

PowerCON TRUE1 Connector

 – AC power entry for the unit. This connector mates with a standard 

PowerCON AC plug to receive input power with a flexible voltage range of 100 to 240 VAC. 

Power Harness with (6 each)

   

Phoenix™ Power Connectors

 – The TTM comes standard with a 6‐

position wiring harness. This 

harness receives its power from the integrated power supply. 

Connector Position Blanking Plates

 – These plates fill unused connector space in the front of the unit. 

 

I/O Connector Positions

 – Input and Output connectors to the TD‐Units are provisioned here. 

 

Rear Connector Plates 

– The unit can be equipped with up to 4 I/O connectors in the rear, allowing for 

easy bidirectional connection. Please note that these plates are differently sized and not interchangeable 

with the front I/O connector plates. 

Enclosure Latch

 – The unit is securely closed screwing the two captive screws in the latch bracket into 

holes on the opposite enclosure half. 

Hinge

 – The reinforced aluminum hinges allow the unit to smoothly swing open for easy service and 

reconfiguration, and swing closed for a compact profile during use. 

Ventilation Fan

 – The unit comes equipped with a quiet running 50 mm fan to remove any exceess 

heated air inside the enclosure.

 

Swivel bracket

 –

 

Attached to the enclosure is a swivelable mounting bracket. Truss clamps are mounted 

in the two slots. The swivel position of the bracket can be adjusted by loosening the thumbscrews, then 

squeezing the two sides together to free the positioning pins. While squeezing, rotate the bracket into the 
desired position, then let go and tighten the thumbscrews. Optionally, wing nuts can be screwed onto the 
thumbscrews and jammed against the mounting bracket threads to provide vibration resistance.

8

17

10

11 

12 

13 

14 

15 

16 

17 

Summary of Contents for TTM

Page 1: ...USER MANUAL 6 Position Truss Mount Enclosure for TD Series Modules with 16 Channel Modular Front Panel TTM...

Page 2: ...cable Repair must only be performed by trained personnel in accordance with the applicable regulations Installation Site Install the unit in a place where the following conditions are met The temperat...

Page 3: ...sal of Used Equipment Used equipment contains valuable raw materials as well as substances that must be disposed of professionally Please dispose of used equipment via an authorized specialist dealer...

Page 4: ...etting Started Initial Inspection Immediately upon receipt inspect the shipping container for damage The container should be retained until the shipment has been checked for completeness and the equip...

Page 5: ...Mounting Options Figure 1 Truss Mount using Cheeseborough Clamps not included Figure 2 Portable Drop Box...

Page 6: ...Down Six tie wrap bases are affixed within the enclosure to allow for clean management of cabling to the TD Series modules Tie wraps can be used to secure cable bundles against the rear and inside hi...

Page 7: ...nt I O connector plates Enclosure Latch The unit is securely closed screwing the two captive screws in the latch bracket into holes on the opposite enclosure half Hinge The reinforced aluminum hinges...

Page 8: ...de to the front of the Mounting Tray until the module stops 4 Repeat steps 1 3 until all desired modules are installed 5 Lower the Retention Bar flat on the tray so that it is on the rear power side o...

Page 9: ...s Note that the screw that protrudes through the hinge bracket is slightly longer than the others 2 Slightly loosen the 4 screws holding the bottom mounting plate to release the modular connector plat...

Page 10: ...Specifications Figure 5 TTM Dimensions Case Open 20 65 524 6 21 48 545 5 2 78 70 7 1 81 46 0 14 28 362 6...

Page 11: ...n 363 mm 11 4 in 290 mm 4 5 in 114 mm 6 5 lb 2 9 kg ELECTRICAL SPECIFICATIONS Min Typ Max Units Power Requirement Voltage Range 100 110 240 VAC Power Line Frequency 50 60 Hz Power Consumption 18 40 W...

Page 12: ...18040 412 Guilford Rd Annapolis Junction MD 20701 fiberplex com clients fiberplex com 301 604 0100 UMTTM 161011...

Reviews: