Figure 3-26
Digitmap and Time Length
2.
Configure VoIP time length parameters. For details of the parameters, see
3.
Click
Apply
to save and apply the configuration.
Table 3-14
Parameters of Digitmap and Time Length
Item
Description
Logplot Mode
The digitmap matching mode. The options include
Max
and
Min
. The
default setting is
Min
.
Regist Period
The SIP registration period. The value range is 120 to 65535 (s), and the
default setting is 3600.
Short Digit Timer
The timeout period set for the short timer. The value range is 1 to 254 (s),
and the default setting is 4.
Long Digit Timer
The timeout period set for the long timer. The value range is 1 to 254 (s),
and the default setting is 10.
Start Digit Timer
The timeout period set for the starting timer. The value range is 1 to 254 (s),
and the default setting is 60.
Long Call Time
The time for long call without response. The value range is 1 to 254 (s), and
the default setting is 60.
54
Version: A
HG6143D Product Manual