AN6000-17 Optical Line Terminal Equipment Hardware Description
(1) M6 ring terminal
(2) Heat-shrinkable tube
(3) Power cable, black
(4) Cord end terminal, ivory
Figure 5-2
0 V Power Cable
Connection
Cable Model
Cable Connector
Connection Description
-48 V power cable
(408000363)
Single-wire cord end terminal
Connected to the -48 V output
connector of the PDP.
M6 ring terminal
Connected to the -48 V interface
of the PIBA card.
0 V power cable
(408000364)
Single-wire cord end terminal
Connected to the 0 V output
connector of the PDP.
M6 ring terminal
Connected to the 0 V interface of
the PIBA card.
Technical Specifications
Cable Model
Cable Type
Color
Maximum
Current
Cross-sectional Area
of Conductor
-48 V power
cable
(408000363)
Single-wire
power cable
Blue
62 A
10.5 mm
2
0 V power cable
(408000364)
Black
5.3
Protection Earth Ground Cable
The protection earth ground cables (including the cabinet protection earth ground
cable, PDP protection earth ground cable and the subrack protection earth ground
cable) protect the equipment from lightning and interference.