15
2. Verify that the baud rate is set to
230400
. Change the baud rate to 230400 if necessary,
but do not change any other parameters.
3. Verify that the Flush Mode Input and Output Buffers are both set to
With Passive
Connect : Yes
4. Verify that the Flush Mode Input and Output Buffers are both set to
With Active
Connect : Yes
5. Click on the
OK
button to confirm the changes. The
Done!
notation appears next to the
OK
button to indicate that changes were applied.
Connection Settings
1. From the main menu in the left-hand panel, select
Channel 1, Connection
. The
Connection Settings
screen displays. The details of what is displayed depends on
whether the connection to the APU will be
incoming
or
outgoing
, so please refer to the
appropriate figure.
a.
Incoming
connections are made from external equipment to the APU. This is
used for integration with the Fiber SenSys Integrator software for Lenel OnGuard
or Milestone XProtect.
i. set the
Accept Incoming
menu to
Yes
ii. set the
Active Connect
menu to
None
.
iii. Verify that the
Local Port
is set to
10001.
Figure 17:
Settings for an
Incoming
Connection