Parameter 152: Incandescence level of dimmable compact fluorescent lamps
The virtual value set as a percentage level between parameters MIN (1%) and MAX. (99%).The device will set to this value after the first switch on. It is required
for warming up and switching dimmable compact fluorescent lamps and certain types of light sources.
Size: 1 Byte, Default Value: 1
Setting
Description
1 - 99
(1-98%, 1% step)level of brightness
Parameter 153: Incandescence time of dimmable compact fluorescent lamps
This parameter determines the time required for switching compact fluorescent lamps and certain types of light sources. Setting this parameter to 0 will disable the
incandescence functionality.
Size: 2 Byte, Default Value: 0
Setting
Description
0 - 255
(0-25.5s, 0.1s step)incandescence time
Parameter 154: Automatic controldimming step size
This parameter defines the percentage value of dimming step during the automatic control.
Size: 1 Byte, Default Value: 1
Setting
Description
1 - 99
(1-99%, 1% step)dimming step
Parameter 155: Automatic controltime of dimming step
This parameter defines the time of performing a single dimming step set in parameter 154 during the automatic control.
Size: 2 Byte, Default Value: 1
Setting
Description
0 - 255
This parameter defines the time of performing a single dimming step set in parameter 154 during the automatic
control.
Parameter 156: Manual controldimming step size
This parameter defines the percentage value of the dimming step during the manual control.
Size: 1 Byte, Default Value: 1
Setting
Description
1 - 99
(1-99%, 1% step)dimming step
Parameter 157: Manual controltime of dimming step
This parameter defines the time of performing a single dimming step set in parameter 156 during the manual control.
Size: 2 Byte, Default Value: 5
Setting
Description
0 - 255
(0-2.55s, 10ms step)
Parameter 158: Auto-off functionality
This parameter allows to automatically switch off the device after a specified time from switching the light source on. It may be useful when the device is installed
in the stairway.
Size: 2 Byte, Default Value: 0
Setting
Description
0
auto-off disabled
1 - 32767
(1s-9.1h, 1s step)auto-off time
Parameter 159: Force auto-calibration
Changing value of this parameter will force the calibration process. During the calibration parameter is set to 1 or 2 and switched to 0 upon completion.
Size: 1 Byte, Default Value: 0
Setting
Description
0
readout
1
force auto-calibration without FIBARO Bypass 2
2
force auto-calibration with FIBARO Bypass 2
Parameter 160: Auto-calibration status (read-only parameter)
This parameter determines operating mode of the device (automatic/manual settings).
Size: 1 Byte, Default Value: 0