18
ADvAnCED PARAMETERS
26. THRESHOLD UP value - „On/Off (Power)” association group (3)
The value of BASIC SET command frame sent to the devices associat-
ed in 3rd group „On/Off (Power)” if power exceeded value of param-
eter 21.
Available settings:
0-99
or
255
Default setting:
255
Parameter size:
2
[bytes]
27. THRESHOLD DOWN value - „On/Off (Power)” association
group (3)
The value of BASIC SET command frame sent to the devices associ-
ated in 3rd group „On/Off (Power)” if power dropped below value of
parameter 22.
Available settings:
0-99
or
255
Default setting:
0
Parameter size:
2
[bytes]
ALARMS
30. Active alarms
Define Z-Wave network alarms to which the Wall Plug will respond.
Available settings:
1
- general alarm
2
- smoke alarm
4
- CO alarm
8
- CO2 alarm
16
- high temperature alarm
32
- flood alarm
Default setting:
63
(all)
Parameter size:
1
[byte]
31. Response to alarm frames
This parameter defines how the Wall Plug will respond to alarms (de-
vice’s status change).
In case of values 1 or 2 the Wall Plug is operating normally and LED
frame signals an alarm through time defined in parameter 32 or until
the alarm is canceled.
In case of values 5 to 50 the Wall Plug does not report status change,
power changes, ignores BASIC SET command frames. After time de-
fined in parameter 32 or after the alarm cancellation, connected de-
vice is set to the previous state.
Available settings:
0
- no reaction,
1
- turn connected device on
2
- turn connected device off
5-50
(0.5-5.0s, step 0.1s) - cyclically change de-
vice state with set period
Default setting:
0
Parameter size:
1
[byte]