13
Z-WAvE SPECIFICATIOn
Notification Command Class:
The device uses notification Command Class to report different events
to the controller (“Lifeline” group).
notification
Type
Event
Event Parameters
Power
Management
[0x08]
Over-load detected [0x08]
Over-current detected [0x06]
System
[0x09]
System hardware Failure
[0x03]
Device overheat
[0x01]
Command Class
version
Secure
Endpoint 1
ZWAvEPLuS_InFO [0x5E]
v2
SECuRITy [0x98]
v1
SECuRITy_2 [0x9F]
v1
ASSOCIATIOn [0x85]
v2
yES
MuLTI_ChAnnEL_ASSOCIATIOn [0x8E]
v3
yES
ASSOCIATIOn_GRP_InFO [0x59]
v2
yES
SuPERvISIOn [0x6C]
v1
yES
SWITCh_BInARy [0x25]
v1
yES
METER [0x32]
v3
yES
nOTIFICATIOn [0x71]
v8
yES
PROTECTIOn [0x75]
v1
yES
Endpoint 2
ZWAvEPLuS_InFO [0x5E]
v2
SECuRITy [0x98]
v1
SECuRITy_2 [0x9F]
v1
ASSOCIATIOn [0x85]
v2
yES
MuLTI_ChAnnEL_ASSOCIATIOn [0x8E]
v3
yES
ASSOCIATIOn_GRP_InFO [0x59]
v2
yES
SuPERvISIOn [0x6C]
v1
yES
METER [0x32]
v3
yES
Multichannel Command Class: