17
ADvAnCED PARAMETERS
„ON/OFF” ASSOCIATION GROUPS
21. UP value - „On/Off (Power)” association group (3)
upper power threshold, used in parameter 23. uP value cannot be
lower than a value specified in parameter 22.
Available settings:
100-30000
(10.0-3000.0W, step 0.1W)
Default setting:
500
(50W)
Parameter size:
2
[bytes]
22. DOWN value - „On/Off (Power)” association group (3)
Lower power threshold, used in parameter 23. DOWn value cannot
be higher than a value specified in parameter 21.
Available settings:
0-29900
(0.0-2990.0W, step 0.1W)
Default setting:
300
(30W)
Parameter size:
2
[bytes]
23. Controlling „On/Off (Power)” association group (3)
This parameter defines the way that 3rd association group devices
are controlled. Depends on the actual measured power (according to
parameters 21 and 22 settings).
Available settings:
1
- send frame (with value set in parameter 26)
only if power exceeded value of parameter 21
2
- send frame (with value set in parameter 27)
only if power dropped below value of parame-
ter 22
3
- send frame in both cases
Default setting:
3
Parameter size:
1
[byte]
24. SWITCH ON value - „On/Off (Button)” association group (2)
The value of BASIC SET command frame sent to the devices associat-
ed in 2nd group „On/Off (Button)” when turning the device On using
the button.
Available settings:
0-99
or
255
Default setting:
255
Parameter size:
2
[bytes]
25. SWITCH OFF value - „On/Off (Button)” association group (2)
The value of BASIC SET command frame sent to the devices associat-
ed in 2nd group „On/Off (Button)” when turning the device OFF using
the button.
Available settings:
0-99
or
255
Default setting:
0
Parameter size:
2
[bytes]
NOTE
Setting parameters
24, 25, 26, 27 to appro-
priate value will result
in:
0
- turning off associ-
ated devices
1-99
- forcing level of
associated devices
255
- setting associat-
ed devices to the last
remembered state or
turning them on
i