Error search
Error Possible
cause
Solution
Filter does not stop automatically after
set time
Steady contact between sensor and filter case
Remove any objects which can cause
contact between the sensor and the
filter case
No water comes out of the spray
nozzles while the clean pump is
working
Fine filter or spray nozzles are blocked
It is air in the cleaning pump
Clean fine filter and spray nozzles
Remove any air out of the cleaning
pump
Filter does not start
Contact switch has no contact
Ensure the contact. Close the cover
with more pressure
Unfiltered water comes out of the outlet
Entering water runs over the rubber seal
Damaged Filter element
Check the correct fitting of rubber
seal
Check installation of filter
Replace damaged filter elements
Blocked wastewater outlet
Wrong angle of wastewater outlet
Correct the angle of wastewater outlet
Filter elements are not getting cleaned
enough
Clean pressure is too low
Cleaning time is too short
Set a higher clean pressure
Set a longer cleaning time
Filter does not start automatically to
clean in mode „Auto“
Water level in drum is too low
Wrong installation of sensor
Check the filter elements for
damages
Check the installation of sensor
Accessories:
Art. No.
Description
2880-1
FIAP TrommelSieve Active element 30, 40, 60, 100 Mikron
2880-2
FIAP TrommelSieve Active cleaning pump
2880-3
FIAP TrommelSieve Active spray nozzle
2880-4
FIAP TrommelSieve Active ball valve DN 100
2427
FIAP GateValve Active 110 mm
2428
FIAP GateValve Active 160 mm
Installation drawing of FIAP TrommelSieve Active gravity version.