EP7
Electronic position indicator
Date: 13/01/16
File: EP7_ing_rev1.7.doc
Page: 6/8
Now press
ENTER
/
RESET
and
3U6W
3U6W
3U6W
3U6W
will appear, press again 2 times
ENTER
/
RESET
and set the correct
value to display, then confirm with
ENTER
/
RESET
.
The display will now show the desired value.
If the required value is zero, instead of the preset function it is possible to use the reset function by
setting 1 in the first digit on the right in the
W$6W,
W$6W,
W$6W,
W$6W,
parameter so that pressing
ENTER
/
RESET
will bring
the displayed value to zero.
Now that the instrument is adjusted, it is necessary to insert the desired
W$6W,
W$6W,
W$6W,
W$6W,
parameter to avoid
accidental reset/preset of the displayed value.
Battery replacement
The instrument is supplied with a ½AA 3,6V lithium battery, which assures a typical functioning of
approximately 4 years.
When the battery runs down, an icon appears on the display.
To enter into the battery-holder it is necessary to remove the front cover by carefully inserting a flat
screwdriver on the sides. After taking off the cover, pull the battery out and substitute it with a new
one, paying attention to the polarity: the positive pole must face the side of the
ENTER
/
RESET
button. The instrument is protected against inversion of polarity and wrong insertion, and in this
case will not switch on.
Removing the battery from the instrument switches it off after a few seconds: at this point do not
rotate the hollow shaft to avoid losing the correct displayed value. As soon as the battery is fitted,
the instrument switches on with the same value on the display which was present at the moment
when it was switched off. If the shaft has not be moved, the displayed value will be correct. In case
the shaft moved when the instrument was off, to re-establish the correct measure it is necessary to
repeat the adjustment process.
Display icons
1.
Indicator of low battery, it is activated when is it necessary to change the battery.
2.
Indicator of inches measurement.
3.
Indicator for origin 1 and 2
4.
Indicator of relative displayed value.
5.
Not used.
Error message
RX(U
RX(U
RX(U
RX(U
: the current displayed value passed the maximum value that can be visualized (possible
range: from –99999 to 99999).
1
2
3
4
5