FIAMA EP7 User Manual Download Page 3

EP7

Electronic position indicator

Date: 13/01/16

File: EP7_ing_rev1.7.doc

Page: 3/8

The safety of the instrument also depends on the strict observance of the procedures indicated in
the manual: always operate the instrument in its functioning capacity and carry out a careful
routine maintenance.
Note:

  All phases of inspection and maintenance should be carried out by qualified staff.

  The configurations provided in the manual are the only ones permitted.

  Do not try to use the instrument in any way which is contrary to the provided indications.

  The instructions in this manual do not substitute but are complimentary to the obligations of

the applicable legislation regarding safety laws.

Installation

Before installing the instrument, take note of the following warnings:

a)  Connect the instrument following strictly the instructions of the manual.
b)  It is the responsibility of the user to check, before using, the correct settings of the parameters

of the instrument to avoid damage to persons or things.

c)  The instrument MUST NOT BE IN FUNCTION IN A DANGEROUS ENVIRONMENT

(inflammable or explosive).

d) The unit has parts sensitive to electrostatic charges, therefore handling of the inner

electronic parts must be carried out with appropriate care to avoid permanent damage.

Description

The electronic position indicator EP7, supplied with an internal battery, integrates in the same case
a position sensor and a display unit, and constitutes a device for measuring linear or angular
movements: it is compact, easy to install and applicable in many types of industry (packaging,
woodworking, aluminum, coil, etc.)
The display has 5 digit plus a sign (range -99999 +99999) with 7,5mm-high digits that allow an
excellent readability also at a distance.
With the 3 frontal buttons it is possible to program the value on the display for each turn of the
hollow shaft and activate the following functions: reset/preset of the displayed value,
absolute/relative displayed value, mm/inches conversion.
There are also 3 distinct origins available for the correction of the displayed value when using
different tools and the offset function for the compensation of tool wear.
On the display all activated functions are showed by a symbol.
The electronic parts are protected inside an elegant and resistant case made of self-extinguishing
and shock-proof plastic material.
The power supply is internal and is based on a single 

½AA 3,6V 

battery which has a typical 4 year

lifetime. Low-power is indicated on the display with an icon; battery substitution is very easy and
does not cause loss of the correct displayed value when carried out without moving the shaft.

Mechanical installation

Fit the EP7 through its hollow shaft onto the machine shaft, taking care that the lock pin fits
correctly into the Ø6mm hole.
For this purpose, prepare the hole for the lock pin (bore 6,1mm, depth 6mm) ensuring that the
distance between the axis of the hole and the axis of the drive shaft is 30mm, see image 1 and 2
below. Then fit the instrument in and fix it with 2 M4 screws placed on the hollow shaft, see image
3 and 4.

1

2

3

4

Summary of Contents for EP7

Page 1: ...EP7 Electronic position indicator Date 13 01 16 File EP7_ing_rev1 7 doc Page 1 8 USER MANUAL EP7 BATTERY POWERED ELECTRONIC POSITION INDICATOR ...

Page 2: ...for its intended use and in potentially explosive conditions or where anti explosive elements are used Storage Here below are some recommendations to be followed for the storage of the instrument Avoid environments with excessive humidity and those exposed to bad weather avoid open areas Avoid placing the instrument directly on the ground Store the instrument in its original packing Conformity dec...

Page 3: ...vice for measuring linear or angular movements it is compact easy to install and applicable in many types of industry packaging woodworking aluminum coil etc The display has 5 digit plus a sign range 99999 99999 with 7 5mm high digits that allow an excellent readability also at a distance With the 3 frontal buttons it is possible to program the value on the display for each turn of the hollow shaf...

Page 4: ...gether with the following one defines the value which is displayed after one rotation of the hollow shaft The allowable range is from 0 0001 to 99999 The decimal place is set after programming the last digit on the left after pressing the decimal place will blink and with it can be moved to the desired position Confirm with ENTER RESET Number of decimal places QG QG QG QG It is the number of decim...

Page 5: ... ABS REL function Enables passing from an absolute to relative value after pressing the displayed value is temporarily set to zero to measure a relative motion of the shaft On the display the REL icon indicates that the current display is relative to the reference point that has just been created Pressing again causes the absolute value to be displayed and the ABS icon will appear mm inch conversi...

Page 6: ...driver on the sides After taking off the cover pull the battery out and substitute it with a new one paying attention to the polarity the positive pole must face the side of the ENTER RESET button The instrument is protected against inversion of polarity and wrong insertion and in this case will not switch on Removing the battery from the instrument switches it off after a few seconds at this poin...

Page 7: ...ctronic position indicator Date 13 01 16 File EP7_ing_rev1 7 doc Page 7 8 Dimensions View A View B BATTERY HOLDER PROGRAMMING BUTTONS DISPLAY DIGIT HEIGHT 7 5mm STAINLESS STEEL HOLLOW SHAFT INCLINED DISPLAY 25 ...

Page 8: ...ol changing Power supply battery AA voltage 3 6V lithium thionyl chloride Battery life Typical 4 years continuous use Weight 100g Protection degree IP54 Working temperature 0 50 C Relative humidity 35 85 Electromagnetic compatibility 2014 30 EU RoHS 2011 65 EU Manufacturer All communications to the manufacturer should be addressed to FIAMA s r l Via G Di Vittorio 5 A 43126 San Pancrazio Parma Ital...

Reviews: