FIAMA EP7 User Manual Download Page 4

EP7

Electronic position indicator

Date: 13/01/16

File: EP7_ing_rev1.7.doc

Page: 4/8

Programming

To access programming of the parameters, keep   pressed until 

3$66

3$66

3$66

3$66

 appears on the display.

Now press 2 times 

ENTER

/

RESET

 and 3 zeroes will appear. The first digit on the right will be

blinking: with   (digit increase) and 

 (digit selection) insert the pass code which is 

273 

and

confirm with 

ENTER

/

RESET

. In case of incorrect insertion of the password, the unit exits

programming.
The various parameters can be scrolled with   and in order of appearance they are:

X,6

X,6

X,6

X,6

value to be displayed after one complete rotation of the shaft

QG(&

QG(&

QG(&

QG(&

number of decimal places

W$6W,

W$6W,

W$6W,

W$6W,

button activation mode *

G,U

G,U

G,U

G,U

counting direction

* When the Offset, Preset, and Origin Change functions are set, also the 

2))6W

2))6W

2))6W

2))6W

,

3U6W

3U6W

3U6W

3U6W

3U6

3U6

3U6

3U6

3U6

3U6

3U6

3U6

,

3U6

3U6

3U6

3U6

 parameters will appear (see further below).

To modify the selected parameter press two times 

ENTER

/

RESET

 (the first time displays only the

value). With   and 

 set the desired value and confirm with 

ENTER

/

RESET

.

To set a negative number, press 

 until the last digit on the left blinks then press 

 once again

and after press   so that the minus sign will appear.
To exit programming press 

.

Value to be displayed after one complete rotation of the hollow shaft: 

X,6

X,6

X,6

X,6

This parameter, together with the following one, defines the value which is displayed after one
rotation of the hollow shaft. The allowable range is from 0,0001 to 99999.
The decimal place is set after programming the last digit on the left: after pressing 

, the decimal

place will blink and with   it can be moved to the desired position. Confirm with 

ENTER

/

RESET

.

Number of decimal places: 

QG(&

QG(&

QG(&

QG(&

It is the number of decimal places to visualize on the display, allowed range from 0 to 4.
Example 1: if each rotation of the hollow shaft will cause a displacement of 50, set 

X,6

X,6

X,6

X,6

=50 and

QG(&

QG(&

QG(&

QG(&

=0.

Example 2: if each rotation of the hollow shaft will cause a displacement of 12,345 and the desired
output on the display is 12.3, set 

X,6

X,6

X,6

X,6

=12.345 and 

QG(&

QG(&

QG(&

QG(&

=1.

Button activation mode: 

W$6W,

W$6W,

W$6W,

W$6W,

This parameter programs the button functions.
The value is a number with 3 digits, each corresponding to a button: the digit on the right sets the

ENTER

/

RESET

 button, the digit in the middle sets   while the last digit on the left sets 

.

The possible values are in the following table:

VALUE

ENTER

/

RESET

0

Not active

Not active

Not active

1

mm/inch conversion

abs/rel

measurement

Reset

2

Not active

Not active

Preset

3

Not active

Not active

Fast Preset

4

Not active

Not active

Change of origin

0,1,2

5

Not active

Not active

Offset

6

Not active

Not active

Fast Offset

7

Not active

Not active

Delayed reset *

(after 3s)

8

Not active

Not active

Delayed preset *

(after 3s)

* Delayed means that to activate the function (reset or preset), it is necessary to keep

ENTER

/

RESET

 pressed for approximately 3 s.

Summary of Contents for EP7

Page 1: ...EP7 Electronic position indicator Date 13 01 16 File EP7_ing_rev1 7 doc Page 1 8 USER MANUAL EP7 BATTERY POWERED ELECTRONIC POSITION INDICATOR ...

Page 2: ...for its intended use and in potentially explosive conditions or where anti explosive elements are used Storage Here below are some recommendations to be followed for the storage of the instrument Avoid environments with excessive humidity and those exposed to bad weather avoid open areas Avoid placing the instrument directly on the ground Store the instrument in its original packing Conformity dec...

Page 3: ...vice for measuring linear or angular movements it is compact easy to install and applicable in many types of industry packaging woodworking aluminum coil etc The display has 5 digit plus a sign range 99999 99999 with 7 5mm high digits that allow an excellent readability also at a distance With the 3 frontal buttons it is possible to program the value on the display for each turn of the hollow shaf...

Page 4: ...gether with the following one defines the value which is displayed after one rotation of the hollow shaft The allowable range is from 0 0001 to 99999 The decimal place is set after programming the last digit on the left after pressing the decimal place will blink and with it can be moved to the desired position Confirm with ENTER RESET Number of decimal places QG QG QG QG It is the number of decim...

Page 5: ... ABS REL function Enables passing from an absolute to relative value after pressing the displayed value is temporarily set to zero to measure a relative motion of the shaft On the display the REL icon indicates that the current display is relative to the reference point that has just been created Pressing again causes the absolute value to be displayed and the ABS icon will appear mm inch conversi...

Page 6: ...driver on the sides After taking off the cover pull the battery out and substitute it with a new one paying attention to the polarity the positive pole must face the side of the ENTER RESET button The instrument is protected against inversion of polarity and wrong insertion and in this case will not switch on Removing the battery from the instrument switches it off after a few seconds at this poin...

Page 7: ...ctronic position indicator Date 13 01 16 File EP7_ing_rev1 7 doc Page 7 8 Dimensions View A View B BATTERY HOLDER PROGRAMMING BUTTONS DISPLAY DIGIT HEIGHT 7 5mm STAINLESS STEEL HOLLOW SHAFT INCLINED DISPLAY 25 ...

Page 8: ...ol changing Power supply battery AA voltage 3 6V lithium thionyl chloride Battery life Typical 4 years continuous use Weight 100g Protection degree IP54 Working temperature 0 50 C Relative humidity 35 85 Electromagnetic compatibility 2014 30 EU RoHS 2011 65 EU Manufacturer All communications to the manufacturer should be addressed to FIAMA s r l Via G Di Vittorio 5 A 43126 San Pancrazio Parma Ital...

Reviews: