EP7

Electronic position indicator

Date: 13/01/16

File: EP7_ing_rev1.7.doc

Page: 2/8

Manual purpose

This manual has been designed by the Manufacturer to provide the necessary information
regarding the EP7 instrument to those who are authorized to carry out safely its installation,
maintenance, dismantling and disposal. All the necessary information for buyers and planners can
be found in the sales catalogue. In addition to adopting good technical construction methods, this
information should be read carefully and strictly applied. Nonobservance of this information could
cause risks for the health and safety of people and economic damage. This information, provided
by the Manufacturer in the original language (Italian) is also available in other languages to satisfy
legislative and/or commercial needs. This manual must be kept in good conditions by a
responsible person in an ideal place so that it is always available for consultation. In case this
manual is lost or deteriorates, a replacement should be requested directly to the manufacturer
quoting the manual code. This manual reflects the state of the instrument at the time of input in
the market: however, the manufacturer reserves the right to make changes, add or improve the
manual without notice.

Identification of the product

The identification label is applied on the instrument.
To determine the identification code of the instrument, consult also the sales catalogue.

Environmental conditions

Temperature range: min. 0°C - max. +50°C.
It is forbidden to use the instrument other than for its intended use and in potentially explosive
conditions or where anti-explosive elements are used.

Storage

Here below are some recommendations to be followed for the storage of the instrument:

  Avoid environments with excessive humidity and those exposed to bad weather (avoid

open areas).

  Avoid placing the instrument directly on the ground.

  Store the instrument in its original packing.

Conformity declaration and EC marking

The instrument respects the following EC Community Directive:
2014/30/EU Electromagnetic compatibility, 2011/65/EU RoHS.

Maintenance

The instrument does not require particular maintenance except cleaning, to be done only with a
soft cloth slightly damped with ethylic alcohol or water. Do not use hydrocarbon solvents (petrol,
thinners, etc.): the use of these products could affect the proper functioning of the instrument.
Repairs should be done only and exclusively at the FIAMA technical assistance centre.

Calibrations and tests

It is advisable to calibrate the instrument periodically, once every working year.
To do the calibration, follow the procedure indicated in the present manual.

Assistance request

For any kind of technical assistance request, contact the sales department of the Manufacturer
directly indicating the information given on the identification label, the number of hours used and
the type of defect.

Manufacturer’s responsibility

The manufacturer declines any responsibility in case of :

  Use of the instrument contrary to the national safety and accident-prevention laws.

  Incorrect installation, incorrect procedures or nonobservance of the instructions provided in

the present manual.

  Defective electrical power supply.

  Modifications or tampering.

  Operations carried out by untrained or unqualified staff.

Summary of Contents for EP7

Page 1: ...EP7 Electronic position indicator Date 13 01 16 File EP7_ing_rev1 7 doc Page 1 8 USER MANUAL EP7 BATTERY POWERED ELECTRONIC POSITION INDICATOR ...

Page 2: ...for its intended use and in potentially explosive conditions or where anti explosive elements are used Storage Here below are some recommendations to be followed for the storage of the instrument Avoid environments with excessive humidity and those exposed to bad weather avoid open areas Avoid placing the instrument directly on the ground Store the instrument in its original packing Conformity dec...

Page 3: ...vice for measuring linear or angular movements it is compact easy to install and applicable in many types of industry packaging woodworking aluminum coil etc The display has 5 digit plus a sign range 99999 99999 with 7 5mm high digits that allow an excellent readability also at a distance With the 3 frontal buttons it is possible to program the value on the display for each turn of the hollow shaf...

Page 4: ...gether with the following one defines the value which is displayed after one rotation of the hollow shaft The allowable range is from 0 0001 to 99999 The decimal place is set after programming the last digit on the left after pressing the decimal place will blink and with it can be moved to the desired position Confirm with ENTER RESET Number of decimal places QG QG QG QG It is the number of decim...

Page 5: ... ABS REL function Enables passing from an absolute to relative value after pressing the displayed value is temporarily set to zero to measure a relative motion of the shaft On the display the REL icon indicates that the current display is relative to the reference point that has just been created Pressing again causes the absolute value to be displayed and the ABS icon will appear mm inch conversi...

Page 6: ...driver on the sides After taking off the cover pull the battery out and substitute it with a new one paying attention to the polarity the positive pole must face the side of the ENTER RESET button The instrument is protected against inversion of polarity and wrong insertion and in this case will not switch on Removing the battery from the instrument switches it off after a few seconds at this poin...

Page 7: ...ctronic position indicator Date 13 01 16 File EP7_ing_rev1 7 doc Page 7 8 Dimensions View A View B BATTERY HOLDER PROGRAMMING BUTTONS DISPLAY DIGIT HEIGHT 7 5mm STAINLESS STEEL HOLLOW SHAFT INCLINED DISPLAY 25 ...

Page 8: ...ol changing Power supply battery AA voltage 3 6V lithium thionyl chloride Battery life Typical 4 years continuous use Weight 100g Protection degree IP54 Working temperature 0 50 C Relative humidity 35 85 Electromagnetic compatibility 2014 30 EU RoHS 2011 65 EU Manufacturer All communications to the manufacturer should be addressed to FIAMA s r l Via G Di Vittorio 5 A 43126 San Pancrazio Parma Ital...