background image

L011-44

Page 4 of 9

2019-05-13

Rev. E1

WARNING / Caution, consult instructions 
for important cautionary information. 

Consult the instructions for use. 

In reference to “Rx only” symbol; this 
applies to USA audiences only

Caution

- Federal law (USA) restricts this 

device to sale by or on the order of a 
physician.

Indicates the catalog number so that 
the medical device can be identified. 

Indicates the manufacturer’s batch 
code so that the batch or lot can be 
identified. 

Indicates the serial number so that 
a specific medical device can be 
identified. 

Indicates the use of Radio-Frequency 
Identification (RFID).

Indications for use

STar™ Drive Platform Adapter Kit is intended to be used with commercially available stereotactic 
systems for neurosurgical procedures which require the accurate positioning of micrelectrodes, 
stimulation electrodes, or other instruments in the brain or nervous system. 

Intended use

STar™ Drive Platform Adapter Kit is intended for use by a neurosurgeon in an operating room 
environment to position and move devices relative to a planned stereotactic system trajectory and 
target. 

Other devices required:

•  Compatible navigation software, such as WayPoint™ Navigator

•  Patient specific microTargeting™ Platform built using fiducial anchor locations and desired 

trajectory

•  Stereotactic device compatible with surgical kit positioners, such as microTargeting™ STar™ 

Drive

Symbol Key

Medical device manufacturer, as 
defined in EU Directives 90/385/EEC, 
93/42/EEC and 98/79/EC. 

Telephone number

Date when the medical device was 
manufactured

Authorized Representative in the 

 

European Community

European Conformity. This device fully 
complies with MDD Directive 93/42/
EEC and legal responsibilities as a 
manufacturer are with FHC, Inc., 1201 
Main Street, Bowdoin, ME 04287 USA.

An item that is known to pose hazards 
in all MRI environments. 

Summary of Contents for STar 66-IT-VP-01

Page 1: ...Drive Adapter Kit for microTargeting Platforms With Intergrated Ring FHC Inc 1201 Main Street Bowdoin ME 04287 USA Fax 1 207 666 8292 24 hour technical service 1 800 326 2905 US Can 1 207 666 8190 FH...

Page 2: ......

Page 3: ...ev E1 2019 05 13 Table of Contents Indications for use Intended use and Other devices required Symbol Key Inventory Cleaning and Sterilization Illustrative Procedure Track Selection Track Offsetting C...

Page 4: ...tion electrodes or other instruments in the brain or nervous system Intended use STar Drive Platform Adapter Kit is intended for use by a neurosurgeon in an operating room environment to position and...

Page 5: ...fication Probe 66 IT VP 01 Inventory 1 3 2 4 5 6 7 8 9 10 12 A 13 14 15 16 11 Purchased Separately A STar Drive M E shown or STar Drive M A Various or STar Drive sold in kits The products referenced i...

Page 6: ...ding to manufacturer s recommendations Asepti Wash Plus liquid 2 5 ml per liter or 1 4 oz per gal using warm tap water 2 Separate the Drive positioners hubs and Lead Holder and immerse them in the was...

Page 7: ...latform using 2 screws at 90 degrees apart Make sure the hub is completely seated in the platform The hub will sit approximately 1 8 above the top surface of the platform 4 Use the burr hole entry mar...

Page 8: ...form MER and implant lead 10 Remove drive from positioner then remove platform 11 Use the standoff wrench to support the standoff while twisting the driver clockwise to secure it to the standoff Turn...

Page 9: ...using positions A H Examples 3mm Offset Positioner in the G position indicated by the dark blue dots in the offsetting chart 3mm Offset Positioner in the B position indicated by the magenta dots in th...

Reviews: