Part A-User Guide & Operator instructions
P123 Part A Rev. 002 March 2016
OUTPUTS
Programming Items Factory set Default
Programming Range (display)
Notes
Show Summary
•
Output Summary
Left Brew FR
Left Bypass FR
Right Brew FR
Right Bypass FR
Screen Contrast
Screen Brightness
Touch To Return
3200
2400
3200
2400
8
8
FR=Flow Rate ml/min
Left Valve
Test OR Calibrate
•
Left Valve Test
(Press to test)
TEST
Press To Test
Runs valve to verify
flow. Have container
under brew-basket!
’’ ’’ ’’ ’’
•
L. Valve Calib
Calibrate
*Flow Rate
1540 to 3200 ml p m
|_________
[]
________|
1400-2800 1950-3800
Factory or service use
for flow rate adjustment
L. Bypass Valve
Test OR Calibrate
If bypass option availble
•
Left Bypass
Valve Test
(Press to test)
TEST
Press To Test
Runs valve to verify
flow. Have container
under brew-basket!
’’ ’’ ’’ ’’
•
L. Bypass Valve
Calib
Calibrate
*Flow Rate
2150 to 2400 ml p m
|_________
[]
________|
1900-2100 2800
Factory or service use
for flow rate adjustment
Left Valve display is only for CBS-2102XTS dual side brewer. CBS-2101XTS Single series displays RIGHT SIDE only
Right Valve
Test OR Calibrate
•
Right Valve Test
(Press to test)
TEST
Press To Test
Runs Valve to verify flow.
Have container under
brew-basket!
’’ ’’ ’’ ’’
•
R. Valve Calib
Calibrate
*Flow Rate
1540 to 3200 ml p m
|_________
[]
________|
1400-2800 1950-3800
Factory or service use
for flow rate
R. Bypass Valve
Test OR Calibrate
If bypass option availble
•
Right Bypass
Valve Test
(Press to test)
TEST
Press To Test
Runs valve to verify
flow. Have container
under brew-basket!
’’ ’’ ’’ ’’
•
R. Bypass
Valve Calib
Calibrate
*Flow Rate
2150 to 2400 ml p m
|_________
[]
________|
1900-2100 2800
Factory or service use
for flow rate adjustment
Fill Valve
•
Fill Valve Test
(Press to test)
TEST
Press To Test
Operates fill valve.
Have container under
both brew-baskets!
Left Basket Lk.
Not on CBS 2130XTS
•
Left brew basket
lock test
(Press to test)
TEST
Press To Test
Energizes brew basket
lock. For factory or
service use
Right Basket Lk.
Not on CBS 2130XTS
•
Right brew
basket lock test
(Press to test)
TEST
Press To Test
Energizes brew basket
lock. For factory or
service use
Heater
•
Heater Test
(Press to test)
TEST
Press To Test
Energizes Heater(s)
Service use only.
Screen
Brightness OR Contrast
•
Screen Contrast
Contrast
8
|____________
[]
____|
1 10
•
S. Brightness
Brightness
8
|____________
[]
____|
1 10
TEST
TEST
TEST
Default-factory set Flow Rates; Brew Valve and Bypass
See “OUTPUTS” right and left brew valve and bypass valve settings and calibration
CBS-2152 & CBS-2162 ml/min
CBS-2151& CBS-2161ml/min
Left Brew FR
3200
Right Brew FR
3200
Left Bypass FR
2400
Right Bypass FR
2400
Right Brew FR
3200
Right Bypass FR
2400
CBS-2132& CBS-2142 ml/min
CBS-2131&CBS-2141 ml/min
Left Brew FR
1540
Right Brew FR
*
1540
Left Bypass FR
*
2150
Right
Bypass
FR
*
2150
Right Brew FR
*
1540
Right Bypass FR
2150
--------------------------------------------------------------------------------------------------------------------
TEST
TEST
TEST
TEST
TEST