Part A-User Guide & Operator instructions
P123 Part A Rev. 002 March 2016
COUNTER Screen, Definition
Total brews on left side
Left Brews
13
Actual brews on left side
Left Brew activated
13
Total volume produced by left side brewer
Left Brew [litr]
39
Actual Bypass used on left side
Left Bypass activated
0
Total volume of left bypass
Left Bypass [litr]
0
Total brews on right side
Right Brews
41
Actual brews on right side
Right Brew activated
41
Total volume produced by right side brewer
Right Brew [litr]
0
Actual Bypass used on right side
Right Bypass activated
0
Total volume of right bypass
Right Bypass [litr]
0
Total cycles activated by fill valve
Fill valve Activated
0
Total cycles activated by fill valve
Fill Valve [litr]
0
Total heater cycles activated Heater
Activated
0
Total time heater has been energized
Heater “ON” time
0:00
Touch To Return
Error Codes
Æ
Contact specialized personnel for error codes
Code
Description
Possible Cause
Corrective Action
How to Clear
Error Codes
001
Software error-error on start
up or corrupted software
Improper start-up
or shutdown
Restart , if still fault: reload
software
050
Short-circuit in
temperature probe
Probe failure.
Replace probe.
051 Open temperature probe.
Bad probe
connection, or
probe failure.
Check all connections.
Replace probe if necessary.
100
Initial Fill Error. Initial fill
time was more than 11
minutes after power up.
Water supply flow
rate is too low.
Watch for short potting
during brew cycle.
Investigate cause of low flow
rate. (Clogged water filter...)
101
Error on refill
Tank did not refill within 3
minutes.
Water supply flow
rate is too low.
Watch for short potting
during brew cycle.
Investigate cause of low flow
rate. (Clogged water filter…)
102 Unwanted
fill;
Possible leak in
tank, fitting, or
valve.
Occurs during pre-fill, low
probe is uncovered
107
Fault
Lower liquid level probe
Tank not filling
Occurs during pre-fill, low
probe is uncovered , or
wires are reversed low / high
probe
201
Heater open, high limit
thermostat, or Solid State
Relay (SSR) fault
Failure of: heating
element, SSR, high
Limit or low voltage
Check and replace heating
elements if necessary.
255 Touch pad error
Usually from longer
than 2 min contact.
Or faulty reassembly
after service
Restart , if still fault: reload
software. If mechanical:
reassemble correctly
INSERT
BREW
BASKET
Brew basket
must be in place
This is a
SAFETY
FEATURE
Insert brew basket into
brewer rails to enable
brewer
TO CLEAR FAULT,
Make repairs as required
Below is the only way
to clear error codes:
1) Enter
“PROGRAMMING”
2)Scroll left to “OTHER”
3)Scroll down to
“ERROR CODES”
4)Scroll down to “Display
Errors”
5)Scroll left to “Reset
Errors”
6)Scroll down to “Reset”
7)Follow directions
shown on screen.
Merely toggling ON/OFF
switch will not clear error
codes.
Error codes must be
cleared by correcting the
fault and entering
PROGRAMMING and
using the menus!
!
Æ
Never attempt to defeat or override a brew basket-locking feature-this is a safety feature