COUNTER Screen, Definition 

Total brews on left side 

Left Brews 

13 

Actual brews on left side 

Left Brew activated 

13 

Total volume produced by left side brewer  

Left Brew [litr] 

39 

Actual Bypass used on left side 

Left Bypass activated 

Total volume of left bypass 

Left Bypass [litr] 

Total brews on right side 

Right Brews 

41 

Actual brews on right side 

Right Brew activated 

41 

Total volume produced by right side brewer  

Right Brew [litr] 

Actual Bypass used on right side 

Right Bypass activated 

Total volume of right bypass 

Right Bypass [litr] 

Total cycles activated by fill valve 

Fill valve Activated 

Total cycles activated by fill valve 

Fill Valve [litr] 

Total heater cycles activated Heater 

Activated 

Total time heater has been energized 

Heater “ON” time 

0:00 

 

Touch To Return

 

 

Error Codes 

Æ

Contact specialized personnel for error codes

 

Code 

Description 

Possible Cause 

Corrective Action 

How to Clear  

Error Codes 

001

 

Software error-error on start 
up or corrupted software 

 

Improper start-up 
or shutdown

 

Restart , if still fault:  reload 
software

 

050 

Short-circuit in 
temperature probe 

Probe failure. 

Replace probe. 

051  Open temperature probe. 

Bad probe 
connection, or 
probe failure. 

Check all connections. 
Replace probe if necessary. 

100 

Initial Fill Error.  Initial fill 
time was more than 11 
minutes after power up. 

Water supply flow 
rate is too low. 

Watch for short potting 
during brew cycle. 
Investigate cause of low flow 
rate. (Clogged water filter...) 

101 

Error on refill 
Tank did not refill within 3 
minutes. 

Water supply flow 
rate is too low. 

Watch for short potting 
during brew cycle. 
Investigate cause of low flow 
rate. (Clogged water filter…) 

102 Unwanted 

fill; 

Possible leak in 
tank, fitting, or 
valve. 

Occurs during pre-fill, low 
probe is uncovered 

107 

Fault  
Lower liquid level probe  

Tank not filling 

Occurs during pre-fill, low 
probe is uncovered , or 
wires are reversed low / high 
probe  

201 

Heater open, high limit 
thermostat, or Solid State 
Relay (SSR) fault 

Failure of: heating 
element, SSR, high 
Limit or low voltage

Check and replace heating 
elements if necessary. 

255  Touch pad error 

Usually from longer 
than 2 min contact. 
Or faulty reassembly 
after service

 

Restart , if still fault:  reload 
software.  If mechanical: 
reassemble correctly 

 

INSERT 

BREW 

BASKET 

 

Brew basket 

must be in place 

 

This is a 

SAFETY 

FEATURE

 

Insert brew basket into 
brewer rails to enable 
brewer 

 
TO CLEAR FAULT,  
Make repairs as required 
 

Below is the only way 

to clear error codes: 

1) Enter 
“PROGRAMMING” 
 
2)Scroll left to “OTHER” 
 
3)Scroll down to 
“ERROR CODES” 
 
4)Scroll down to “Display 
Errors” 
 
5)Scroll left to “Reset 
Errors” 
 
6)Scroll down to “Reset”  
 
7)Follow directions 
shown on screen. 
 
Merely toggling ON/OFF 
switch will not clear error 
codes. 
 
Error codes must be 
cleared by correcting the 
fault and entering 
PROGRAMMING and 
using the menus!

 

Æ

 Never attempt to defeat or override a brew basket-locking feature-this is a safety feature 

Summary of Contents for Touchscreen 1.0 CBS-2100XTS

Page 1: ...n Models CBS 2100XTS CBS 2131XTS Configured as 3 liter CBS 2132XTS Configured as 1 gallon Two Part User Guide FETCO Extractor Touch Screen Models CBS 2100XTS Extractor Touch Screen Commercial Hot Beve...

Page 2: ...cked Return to home screen First Brew I In ns st tr ru uc ct ti io on ns s f fo or r b br re ew w o op pe er ra at ti io on n f fa as st t b br re ew w Setup is simple 1 Connect unit to water and elec...

Page 3: ...2 Ready Heating Filling Touch screen to unlock INFO STOP 04 44 INFO STOP 05 30 Regular 1 3 00 6 00 Regular 2 3 00 6 00 Decaf 1 3 00 6 00 Decaf 2 3 00 6 00 INFO STOP 05 30 1 Home screen activated twin...

Page 4: ...to save changes and exit 7 The chart on the next page give the general service menu topics the pages following list the details of the topics When navigating up to EXIT leaves the Service Menu Screen...

Page 5: ...OTHER Batch 1 Right Or Batch 1 Left Tank Temp Display Inputs Show Summary Error Codes Batch 2 Right Or Batch 2 Left Brew at Temp Calibrate Touch Screen Left Valve Copy Program Batch 3 Right Or Batch...

Page 6: ...r1 Regular 1 16 OR Write any name Models CBS 2130 CBS 2140 CBS 2150 CBS 2160XTS Batch Volume 0 80 to 3 00 gal 3L 1gal 3 00 gal _________ ________ 0 25 0 5gal 1 25 3 10gal Screen will display in range...

Page 7: ...00 2591 185 196 0 85 91 1 X XT TS S E EX XT TR RA AC CT TO OR R T TO OU UC CH HS SC CR RE EE EN N CBS 2100XTS Ready Heating Filling Tank Temp 200 F Regular 1 1 00 5 30 Regular 2 1 00 5 30 Decaf 1 1 00...

Page 8: ...ized Tank Temp 93 C Cal Touch Scr Calibrate Calibrate ________________ ____ YES NO If Yes Follow directions on the touch screen INPUT SUMMARY SCREEN Display Inputs See INPUTS Service Screen Brew Baske...

Page 9: ...00 2800 1950 3800 Factory or service use for flow rate R Bypass Valve Test OR Calibrate If bypass option availble Right Bypass Valve Test Press to test TEST Press To Test Runs valve to verify flow Hav...

Page 10: ...ces fl oz multiply by 29 57 to convert to milliliters After entering the measured volume exit PROGRAMMING and return to the normal screens 3 MANUAL METHOD Operator input CALIBRATE THE FLOW RATE Use th...

Page 11: ...ion CBS_2131 3L CBS_2131 1G CBS_2132 3L CBS_2132 1G CBS_2141 CBS_2142 CBS_2151 CBS_2152 2152 2G CBS_2161 CBS_2162 Screen appears after pressing Res to Factory Above Select Model CBS 2131 2152 Series _...

Page 12: ...me was more than 11 minutes after power up Water supply flow rate is too low Watch for short potting during brew cycle Investigate cause of low flow rate Clogged water filter 101 Error on refill Tank...

Page 13: ...dispenser cleaner such as URNEX TABZ DIP IT or Squeak n Clean 2 Carefully Follow the instructions supplied with the cleaning product 3 Never use spray cleaners solvent solvent based cleaner or petrol...

Page 14: ...Go to fetco com for the latest versions of all information P123 REV 002 END OF SECTION NOTES...

Page 15: ...Service Technicians Only Models CBS 2130XTS Extractor Touch Screen Commercial Hot Beverage Equipment FETCO Touch Screen Models CBS 2130XTS Airpot and dispenser series CBS 2131 3 liter CBS 2132 3 lite...

Page 16: ...003 International Code Council ICC or to the Uniform Plumbing Code 2003 IAPMO 3 Use an inline water filter for all beverage equipment 4 Install the filter unit after a water shutoff valve and in a pos...

Page 17: ...wire plus ground electrical Configuration Codes Heater Configuration Voltage Phase Wires Electrical Connection KW Amp Draw Brew Volume Hour 3 liters per batch E213172 1 X 1 7 kW 120 1 2 G NEMA 5 15P 1...

Page 18: ...t Total Weight Brewer Filled Dispenser Hot Water Tank Capacity Shipping Weight Shipping Dimensions CBS 2131XTS Single 3 liter 26 666mm 11 303mm 20 516mm 29 lb 13 2kg 55 lb 25 kg 66 2lb 34 6 kg 3 3 gal...

Page 19: ...ght Total Weight Brewer Filled Dispenser Hot Water Tank Capacity Shipping Weight Shipping Dimensions CBS 2132XTS Dual 3 liter 26 666mm 19 502mm 20 518mm 47lb 21 3kg 92lb 41 7kg 114 4lb 51 9 kg 5 8 gal...

Page 20: ...unit warranty and may lead to electric shock or burn as well as damage to unit and or its surroundings 7 If the power cord requires repair or replacement it must be performed by the manufacturer or au...

Page 21: ...15 16 x 3 32 5 Valve rebuild kit 1000 00098 00 Kit contains SPRING DIAPHRAGM PLUNGER Brew Basket Parts Complete Plastic Brew Basket STANDARD Part Number B014218BN2 CBS 2130XTS Part Number Plug Insert...

Page 22: ...to fetco com for the latest version of all information Part B page 8 P123 partB REV 002 Technical Supplement March 2016 Parts diagrams CBS 2131XTS Parts Drawing CBS 2131 XTS Drawing number 1101 00151...

Page 23: ...DRAIN FOR 18GA AND UP BODY 22 1 1024 00040 00 CARD PLUG HWD 2100 23 1 1102 00210 00 ASSEMBLY FRONT PANEL CBS 2130 24 5 1082 00058 00 SCREW 8 32 X 5 8 FLAT HD PH 18 8 SS 25 1 1102 00259 00 LOCATOR ASSE...

Page 24: ...00 ALUMINUM BRACKET FOR SSR 7 1 2 1052 00033 00 RELAY SOLID STATE 50A 480VAC W BUILD IN VARISTOR 8 2 2 1081 00042 00 STANDOFF 1 4 HEX 9 1 1 1112 00002 00 PROBE WELDMENT WATER LEVEL 2 25 LG 10 1 1 1102...

Page 25: ...3 1 1083 00011 00 WASHER 8 SCREW SIZE INTERNAL TOOTH LOCK 4 2 1083 00016 00 WASHER 8 SCREW SIZE FLAT 5 1 1086 00008 00 CONNECTOR CABLE CLAMP 3 4 6 1 1058 00020 00 SWITCH PWR ROCKER RED ILLUM 250VAC 7...

Page 26: ...Go to fetco com for the latest version of all information Part B page 12 P123 partB REV 002 Technical Supplement March 2016 CBS 2132 XTS Drawing number 1104 00050 00...

Page 27: ...1 1025 00028 00 TUBE 5 8 OD X 3 8 ID X 11 LG HOT WATER VALVE IN 24 12 1084 00011 00 NUT CLIP ON J NUT 6 32 22 20 GA BLK PH FINISH 25 1 1102 00208 00 ASSEMBLY BACK PANEL CBS 2132 AND 2142 26 13 1082 0...

Page 28: ...SSEMBLY IMMERSION 2300W 240VAC 8 2 1107 00018 00 HEATER ASSEMBLY IMMERSION 3000W 240VAC 9 4 1084 00010 00 NUT HEX 6 32 UNDERSIZED ZINC PLATED 10 2 1003 00140 00 ALUMINUM BRACKET FOR SSR 11 2 1052 0003...

Page 29: ...IP 3 1 1083 00011 00 WASHER 8 SCREW SIZE INTERNAL TOOTH LOCK 4 2 1083 00016 00 WASHER 8 SCREW SIZE FLAT 5 1 1086 00008 00 CONNECTOR CABLE CLAMP 3 4 6 1 1058 00020 00 SWITCH PWR ROCKER RED ILLUM 250VAC...

Page 30: ...Go to fetco com for the latest version of all information Part B page 16 P123 partB REV 002 Technical Supplement March 2016 CBS 2131XTS WATER HANDELING LAYOUT...

Page 31: ...Go to fetco com for the latest version of all information Part B page 17 P123 partB REV 002 Technical Supplement March 2016 CBS 2132XTS WATER HANDELING LAYOUT...

Page 32: ...UMBER Heater Configuration E213251 2 X 2 3 kW 240 Vac E213252 2 X 3 0 kW 240 Vac Go to fetco com for the latest version of all information Part B page 18 P123 partB REV 002 Technical Supplement March...

Page 33: ...Number Heater Configuration E213151 1 X 2 3 kW 120Vac E213153 1 X 1 5 kW 120Vac Go to fetco com for the latest version of all information Part B page 19 P123 partB REV 002 Technical Supplement March 2...

Page 34: ...latest version of all information Part B page 20 P123 partB REV 002 Technical Supplement March 2016 SKU Number Heater Configuration E213157 1 X 3 0 kW 240Vac Go to fetco com for the latest version of...

Page 35: ...120 Vac Cord and Plug from Factory OPTION BY USER 2 X 1 7 kW 120 208 240Vac to terminal block field installed E213173 1 X 2 3 kW 120 Vac Cord and Plug from Factory OPTION BY USER 2 X 2 3 kW 120 208 2...

Page 36: ...amming path and use arrows to locate Select Model programming screen 7 Use right and left arrow icons to navigate to Restore to Factory defaults Res to Factory screen 7 8 Use down arrow to set brewer...

Page 37: ...with 3 liter airpot Locator Factory installed Shown with 1 gallon dispenser locator User option Layout of the brewer Operation and service Touch screen for brewer operation Brew basket SD card interfa...

Page 38: ...Go to fetco com for the latest versions of all information P123 REV 002 END OF SECTION NOTES...

Reviews: