Fetco Touchscreen 1.0 CBS-2100XTS Users Manual And Operator Instructions Download Page 7

Go to fetco.com for the latest versions of all information         

Page 7

        

Part A-User Guide & Operator instructions

 

P123 Part A Rev. 002 March 2016

 

 

GENERAL 

Programming Items 

Factory set  Default 

Programming Range

 

Notes

 

 

  Tank Temp. 

200°F 

[200  °F] 

|______________

[]

___| 

77C/170F      97C/207F

 

Chart to correct for 
high altitude below 

OFF

 allows 

brewing at any 
temperature. 

 

  Brew at Temp. 

“ON” 

ON 

|________

[]

_______| 

OFF       ON   AUTO

 

SEE NOTE BELOW!  

 

  Units of Meas.  

 

 Temperature  

°C or °F 

°F 

|___

[]

____________| 

°F              °C 

[Switchable Units] 

 

  Volume  

Gallons [Liters] 

Gallons 

|_____________

[]

__| 

Gallons       Liters

 

[Switchable Units] 

Energy 

Saving Mode 

  ECO Mode 

OFF 

ECO Mode

 

_______________

[]

_____ 

ON               OFF

 

If Selected: After 1 hour of 

inactivity

Æ

Lowers hot water 

tank temperature to 170

°

 

 

  Logo Timeout 

0:15 mm:ss 

0:15 mm:ss 

|__

[]

___________| 

0:15                    5:00

 

 

This is a  

Safety Feature

 

  Brew B. Sensor 

NORMAL 

(SEE WARNINGS) 

NORMAL 

|__

[]

____________| 

NORMAL     OVERRIDE

 

Factory or service use for 

servicing. 

NORMAL

 is 

recommended for safety.  

 

 

  Use Flowjet 

NO 

NO

 

____

[]

_______________ 

NO                YES 

Trims water handling 

system for Flowjet 

“NORMAL” for 
most water 
“HIGH” for R.O.

 

  LLC Sensitivity 

NORMAL 

NORMAL

 

____

[]

______________ 

NORMAL                HIGH 

Liquid level control sensitivity. 

High is for reverse osmosis 

water or very pure water.

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Chart to correct for altitude for boiling point   

in tank water temperature.

 

[ft] [m] 

Suggested 
Setting[°F] 

Boiling 

point[°F] 

Suggested 

Setting[°C] 

Boiling 

point [°C] 

0 0  205 212.0 96 100.0 

500 152  205

 

211.0 96

 

99.5 

1000 305  200

 

210.1 93

 

98.9 

2000 610  200

 

208.1 93

 

97.8 

2500 762  200

 

207.2 93

 

97.3 

3000 914  200

 

206.2 93

 

96.8 

3500 1067  197  205.3  92 

96.3 

4000 1219  195  204.3  91 

95.7 

4500 1372  194  203.4  90 

95.2 

5000 1524  194  202.4  90 

94.7 

5500 1676  193  201.5  89 

94.2 

6000 1829  192  200.6  89 

93.6 

6500 1981  191  199.6  88 

93.1 

7000 2134  190  198.7  87 

92.6 

7500 2286  188  197.8  86 

92.1 

8000 2438  187  196.9  86 

91.6 

8500 2591  185  196.0  85 

91.1 

X

X

T

T

S

S

 

 

E

E

X

X

T

T

R

R

A

A

C

C

T

T

O

O

R

R

 

 

T

T

O

O

U

U

C

C

H

H

S

S

C

C

R

R

E

E

E

E

N

N

CBS 2100XTS 

 

Ready 

 

Heating 

 

Filling

 

Tank Temp 

200

°F 

Regular 1 

|

| 1:00 

Ÿ

 5:30

Regular 2 

|

| 1:00 

Ÿ

 5:30

Decaf 1 

|

| 1:00 

Ÿ

 5:30

Decaf 2 

|

| 1:00 

Ÿ

 5:30

 
STOP

 

INFO

 

200°F

BREW AT TEMPERATURE DEFINITONS 

--------------------------------------------------------------------------------

 

BREW AT TEMP:  “

ON

” 

(DEFAULT: FACTORY PROGRAMMED INTO BREWER) 

“BREW START” Batch Section Pennants will not be accessible 
until tank temperature is at set point. 
The “BREW START” screens with the Batch Section Pennants 
become accessible when hot water tank is at the selected 
temperature.  A screen (example to the right) will display 
and show “BREW AT TEMP” is selected. 

Æ

 

 -------------------------------------------------------------------------------- 

BREW AT TEMP

:  AUTO              USER SELECTABLE  

“BREW START” will pause if the hot water tank is not at the 
selected temperature—and automatically start when it is at the 
set temperature. 
If the temperature is too low, the brewer will wait until the proper 
temperature is reached. A screen (example to the right) will 
display showing a thermometer icon and the tank temperature

Æ

IMPORTANT: ALWAYS have dispenser(s) under the brewer 
when in the BREW AT TEMP mode 
 ---------------------------------------------------------------------------------------------------------- 

BREW AT TEMP:

  

OFF

             

USER SELECTABLE       (Not recommended) 

Allows brewing at any temperature above 170°F/82°C. 

ECO MODE-Energy saving mode DEFINITONS 

If Selected

: Turns heaters off after 1 hour of inactivity.   

The hot water tank temperature will slowly decline to no lower than 60°C/170°F  
A screen (example to the right) will display showing “ECO Mode” is activated.  

Æ

 

To return from ECO-Mode 

Tap the screen, ECO Mode turns off, and the brewer will heat to set temperature. 
It takes approximately 7-15 minutes to return from 60°C/170°F to factory default 93°C/200°F  

All FETCO commercial hot beverage equipment have well insulated hot water tanks and have 
engineered mechanical features to limit energy consumption. 
Effective construction and insulation increases equipment life and lowers building HVAC costs.  
 FETCO hot beverage equipment have the best energy savings of all major suppliers. 

XTS

 

EXTRACTOR 

TOUCHSCREEN

 

 

CBS 2100XTS 

 

ECO 

 

Heating 

 

Filling

 

Tank Temp 

170

 

°F 

Summary of Contents for Touchscreen 1.0 CBS-2100XTS

Page 1: ...n Models CBS 2100XTS CBS 2131XTS Configured as 3 liter CBS 2132XTS Configured as 1 gallon Two Part User Guide FETCO Extractor Touch Screen Models CBS 2100XTS Extractor Touch Screen Commercial Hot Beve...

Page 2: ...cked Return to home screen First Brew I In ns st tr ru uc ct ti io on ns s f fo or r b br re ew w o op pe er ra at ti io on n f fa as st t b br re ew w Setup is simple 1 Connect unit to water and elec...

Page 3: ...2 Ready Heating Filling Touch screen to unlock INFO STOP 04 44 INFO STOP 05 30 Regular 1 3 00 6 00 Regular 2 3 00 6 00 Decaf 1 3 00 6 00 Decaf 2 3 00 6 00 INFO STOP 05 30 1 Home screen activated twin...

Page 4: ...to save changes and exit 7 The chart on the next page give the general service menu topics the pages following list the details of the topics When navigating up to EXIT leaves the Service Menu Screen...

Page 5: ...OTHER Batch 1 Right Or Batch 1 Left Tank Temp Display Inputs Show Summary Error Codes Batch 2 Right Or Batch 2 Left Brew at Temp Calibrate Touch Screen Left Valve Copy Program Batch 3 Right Or Batch...

Page 6: ...r1 Regular 1 16 OR Write any name Models CBS 2130 CBS 2140 CBS 2150 CBS 2160XTS Batch Volume 0 80 to 3 00 gal 3L 1gal 3 00 gal _________ ________ 0 25 0 5gal 1 25 3 10gal Screen will display in range...

Page 7: ...00 2591 185 196 0 85 91 1 X XT TS S E EX XT TR RA AC CT TO OR R T TO OU UC CH HS SC CR RE EE EN N CBS 2100XTS Ready Heating Filling Tank Temp 200 F Regular 1 1 00 5 30 Regular 2 1 00 5 30 Decaf 1 1 00...

Page 8: ...ized Tank Temp 93 C Cal Touch Scr Calibrate Calibrate ________________ ____ YES NO If Yes Follow directions on the touch screen INPUT SUMMARY SCREEN Display Inputs See INPUTS Service Screen Brew Baske...

Page 9: ...00 2800 1950 3800 Factory or service use for flow rate R Bypass Valve Test OR Calibrate If bypass option availble Right Bypass Valve Test Press to test TEST Press To Test Runs valve to verify flow Hav...

Page 10: ...ces fl oz multiply by 29 57 to convert to milliliters After entering the measured volume exit PROGRAMMING and return to the normal screens 3 MANUAL METHOD Operator input CALIBRATE THE FLOW RATE Use th...

Page 11: ...ion CBS_2131 3L CBS_2131 1G CBS_2132 3L CBS_2132 1G CBS_2141 CBS_2142 CBS_2151 CBS_2152 2152 2G CBS_2161 CBS_2162 Screen appears after pressing Res to Factory Above Select Model CBS 2131 2152 Series _...

Page 12: ...me was more than 11 minutes after power up Water supply flow rate is too low Watch for short potting during brew cycle Investigate cause of low flow rate Clogged water filter 101 Error on refill Tank...

Page 13: ...dispenser cleaner such as URNEX TABZ DIP IT or Squeak n Clean 2 Carefully Follow the instructions supplied with the cleaning product 3 Never use spray cleaners solvent solvent based cleaner or petrol...

Page 14: ...Go to fetco com for the latest versions of all information P123 REV 002 END OF SECTION NOTES...

Page 15: ...Service Technicians Only Models CBS 2130XTS Extractor Touch Screen Commercial Hot Beverage Equipment FETCO Touch Screen Models CBS 2130XTS Airpot and dispenser series CBS 2131 3 liter CBS 2132 3 lite...

Page 16: ...003 International Code Council ICC or to the Uniform Plumbing Code 2003 IAPMO 3 Use an inline water filter for all beverage equipment 4 Install the filter unit after a water shutoff valve and in a pos...

Page 17: ...wire plus ground electrical Configuration Codes Heater Configuration Voltage Phase Wires Electrical Connection KW Amp Draw Brew Volume Hour 3 liters per batch E213172 1 X 1 7 kW 120 1 2 G NEMA 5 15P 1...

Page 18: ...t Total Weight Brewer Filled Dispenser Hot Water Tank Capacity Shipping Weight Shipping Dimensions CBS 2131XTS Single 3 liter 26 666mm 11 303mm 20 516mm 29 lb 13 2kg 55 lb 25 kg 66 2lb 34 6 kg 3 3 gal...

Page 19: ...ght Total Weight Brewer Filled Dispenser Hot Water Tank Capacity Shipping Weight Shipping Dimensions CBS 2132XTS Dual 3 liter 26 666mm 19 502mm 20 518mm 47lb 21 3kg 92lb 41 7kg 114 4lb 51 9 kg 5 8 gal...

Page 20: ...unit warranty and may lead to electric shock or burn as well as damage to unit and or its surroundings 7 If the power cord requires repair or replacement it must be performed by the manufacturer or au...

Page 21: ...15 16 x 3 32 5 Valve rebuild kit 1000 00098 00 Kit contains SPRING DIAPHRAGM PLUNGER Brew Basket Parts Complete Plastic Brew Basket STANDARD Part Number B014218BN2 CBS 2130XTS Part Number Plug Insert...

Page 22: ...to fetco com for the latest version of all information Part B page 8 P123 partB REV 002 Technical Supplement March 2016 Parts diagrams CBS 2131XTS Parts Drawing CBS 2131 XTS Drawing number 1101 00151...

Page 23: ...DRAIN FOR 18GA AND UP BODY 22 1 1024 00040 00 CARD PLUG HWD 2100 23 1 1102 00210 00 ASSEMBLY FRONT PANEL CBS 2130 24 5 1082 00058 00 SCREW 8 32 X 5 8 FLAT HD PH 18 8 SS 25 1 1102 00259 00 LOCATOR ASSE...

Page 24: ...00 ALUMINUM BRACKET FOR SSR 7 1 2 1052 00033 00 RELAY SOLID STATE 50A 480VAC W BUILD IN VARISTOR 8 2 2 1081 00042 00 STANDOFF 1 4 HEX 9 1 1 1112 00002 00 PROBE WELDMENT WATER LEVEL 2 25 LG 10 1 1 1102...

Page 25: ...3 1 1083 00011 00 WASHER 8 SCREW SIZE INTERNAL TOOTH LOCK 4 2 1083 00016 00 WASHER 8 SCREW SIZE FLAT 5 1 1086 00008 00 CONNECTOR CABLE CLAMP 3 4 6 1 1058 00020 00 SWITCH PWR ROCKER RED ILLUM 250VAC 7...

Page 26: ...Go to fetco com for the latest version of all information Part B page 12 P123 partB REV 002 Technical Supplement March 2016 CBS 2132 XTS Drawing number 1104 00050 00...

Page 27: ...1 1025 00028 00 TUBE 5 8 OD X 3 8 ID X 11 LG HOT WATER VALVE IN 24 12 1084 00011 00 NUT CLIP ON J NUT 6 32 22 20 GA BLK PH FINISH 25 1 1102 00208 00 ASSEMBLY BACK PANEL CBS 2132 AND 2142 26 13 1082 0...

Page 28: ...SSEMBLY IMMERSION 2300W 240VAC 8 2 1107 00018 00 HEATER ASSEMBLY IMMERSION 3000W 240VAC 9 4 1084 00010 00 NUT HEX 6 32 UNDERSIZED ZINC PLATED 10 2 1003 00140 00 ALUMINUM BRACKET FOR SSR 11 2 1052 0003...

Page 29: ...IP 3 1 1083 00011 00 WASHER 8 SCREW SIZE INTERNAL TOOTH LOCK 4 2 1083 00016 00 WASHER 8 SCREW SIZE FLAT 5 1 1086 00008 00 CONNECTOR CABLE CLAMP 3 4 6 1 1058 00020 00 SWITCH PWR ROCKER RED ILLUM 250VAC...

Page 30: ...Go to fetco com for the latest version of all information Part B page 16 P123 partB REV 002 Technical Supplement March 2016 CBS 2131XTS WATER HANDELING LAYOUT...

Page 31: ...Go to fetco com for the latest version of all information Part B page 17 P123 partB REV 002 Technical Supplement March 2016 CBS 2132XTS WATER HANDELING LAYOUT...

Page 32: ...UMBER Heater Configuration E213251 2 X 2 3 kW 240 Vac E213252 2 X 3 0 kW 240 Vac Go to fetco com for the latest version of all information Part B page 18 P123 partB REV 002 Technical Supplement March...

Page 33: ...Number Heater Configuration E213151 1 X 2 3 kW 120Vac E213153 1 X 1 5 kW 120Vac Go to fetco com for the latest version of all information Part B page 19 P123 partB REV 002 Technical Supplement March 2...

Page 34: ...latest version of all information Part B page 20 P123 partB REV 002 Technical Supplement March 2016 SKU Number Heater Configuration E213157 1 X 3 0 kW 240Vac Go to fetco com for the latest version of...

Page 35: ...120 Vac Cord and Plug from Factory OPTION BY USER 2 X 1 7 kW 120 208 240Vac to terminal block field installed E213173 1 X 2 3 kW 120 Vac Cord and Plug from Factory OPTION BY USER 2 X 2 3 kW 120 208 2...

Page 36: ...amming path and use arrows to locate Select Model programming screen 7 Use right and left arrow icons to navigate to Restore to Factory defaults Res to Factory screen 7 8 Use down arrow to set brewer...

Page 37: ...with 3 liter airpot Locator Factory installed Shown with 1 gallon dispenser locator User option Layout of the brewer Operation and service Touch screen for brewer operation Brew basket SD card interfa...

Page 38: ...Go to fetco com for the latest versions of all information P123 REV 002 END OF SECTION NOTES...

Reviews: