Fetco TEAVARIS PLUS TBS-1221 Users Manual And Operator Instructions Download Page 5

Go to fetco.com for the latest versions of all information         

Page 5

      

User Guide & Operator instructions

  

P209

Re0

August 2021

 

Programing Menu Layout

 

 

 

 

A10 to A70 

 

B10-B40 

 

C10-C50 

 

D10-D90 

 

E10-E70 

 

F10-F120 

 

G1-G15 

 

H10-H11 

 

 

Batch Parameters 

 

General Settings 

 

Service Inputs 

 

Service Outputs 

 

Calibration 

 

Service Menu 

 

Counters 

 

Exit and Save 

 

 

 

 

 

 

 

 

 

 

A11 

Brew Volume 

B1 

Tank Temperature 

C1 

LLC Probe 

D1 

Heater SSR 

E1 

Ready Temp. Offset 

F1 

Firmware Ver. 

G1 

Filter Used 

H1 

Save Changes 

 

 

 

 

 

 

 

 

 

 

A12 

Brew Time 

B2 

Brew at Temp 

C2 

Basket Sensor 

D2 

Fill Valve 

E2 

LLC Sensitivity 

F2 

Bootloader Ver. 

G2 

Filter Life 

H2 

EXIT? 

 

 

 

 

 

 

 

 

 

 

 

A13 

Prewet Percent 

B3 

Batch Temp 

C4 

Tank Temperature 

D4 

Brew Valve 

E3 

Slow Flow Compensate 

F3 

Select Model 

G3 

Filter Reset 

 

 

 

 

 

 

 

 

 

 

 

 

 

A14 

Prewet Delay 

B4 

Show Tank Temp 

C5 

USB Drive 

D10 

Dilute Valve 

E5 

Brew Flow 

F5 

Option BB Lock 

G4 

Counter Reset 

 

 

 

 

 

 

 

 

 

 

 

 

 

A16 

Drip Delay 

B5 

Units of Temp. 

C6 

Keyboard Test 

D12 

LCD Brightness % 

E9 

Dilute Flow 

F8 

Backup to USB 

G5 

Choose Counter 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A17 

Dilute Mode 

B6 

Units of Volume 

 

 

D13 

LED Brightness % 

 

 

F9 

Restore from USB 

G10 

Brewer Volume 

[LT]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A17 

Dilute Delay 

B7 

Customers Name 

 

 

 

 

 

 

F10 

Restore Defaults 

G11 

Brewer Volume [R] 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A17 

Dilute Volume 

B7 

Add Name 

 

 

 

 

 

 

F11 

Error Log 

G14 

Rt Brews [LT] 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A20 

Batch Enabled 

B9 

Demo Mode 

 

 

 

 

 

 

F12 

Erase Error Log 

G15 

Rt Brews [R] 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A30 

Batch Enabled 

B10 

Eco Mode 

 

 

 

 

 

 

F13 

Service Phone# 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A90 

Copy Batch 

 

 

 

 

 

 

 

 

F15 

Override Rt BBS 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A91 

Copy Batch: From 

 

 

 

 

 

 

 

 

F17 

Override Rt BBL 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A92 

PASTE: To 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

   

 

 

 

Do not exit Programming by turning brewer off/on, all settings will be lost.   

Follow the steps shown in the chart below to exit and save settings. 

 

Exit Programming & Save Settings and Changes   Control Setting Changes 

 

 

 

 

 

From any screen- 

Press STOP button 

until the EXIT (“H”)  

screen appears 

From the “H” screen 

Press button 

2

 to 

toggle to the EXIT-

YES

 screen 

From EXIT screen 

Press  button 

1

 to 

toggle to the SAVE 

screen 

From SAVE screen 

Press button 

2

 to toggle 

to the SAVE-

YES

 

screen 

To SAVE and EXIT 

Press button 

1

 to SAVE 

your changes and EXIT to  

OPERATING MODE  

 

 

 

 

STOP 

 

 

 

Programming A-F 

A-F 

 

 

 

 

STOP 

 

EXIT 

YES    - 

 

 

 

 

 

STOP 

 

 

 

SAVE 

NO  + 

 

 

 

 

STOP 

 

 

 

SAVE 

YES  - 

 

 

 

 

 

STOP 

 

EXIT 

NO    + 

 

 

 

 

Summary of Contents for TEAVARIS PLUS TBS-1221

Page 1: ...d Tea Brewer FETCO TEAVARIS PLUS Commercial Beverage Equipment TBS 1221 Single Dilution Teavaris Plus TBS 1222 Dual Dilution Teavaris Plus Shown with ITD dispensers not included CONTACT INFORMATION FE...

Page 2: ...es Electrical Specifications for single domestic 120 volt cord and plug SKU Dilution Electrical Connection Heater Configuration Voltage KW Amp Draw Est 3gal Batches Hour T1221US 1A117 PM001 Domestic S...

Page 3: ...n a receiving dispenser for the left or right side brew orientation TBS 1221 Single dilution has a square brew basket and is only positioned in the center for three recipes A1 A2 and A3 Two position b...

Page 4: ...ze and then display digital process notifications 3 After Initialization STOP Lamp turns on 4 Quickly press STOP button no need to hold When brewer is In PROGRAMMING MODE the screen will display BATCH...

Page 5: ...kup to USB G5 Choose Counter A17 Dilute Mode B6 Units of Volume D13 LED Brightness F9 Restore from USB G10 Brewer Volume LT A17 Dilute Delay B7 Customers Name F10 Restore Defaults G11 Brewer Volume R...

Page 6: ...after brew to begin dilution Often used to add sweetener A172 Dilution Volume 308 oz 9 1 liters 2 4 gallons 1 512oz 0 00 15 15 liters 0 00 4 0 gallons 1 oz 0 05L 0 01G Unit default is fluid ounces Can...

Page 7: ...ess STOP to scroll through more sections See SAVE EXIT on page 5 or 14 For TBS 1222 only proceed to A4 A5 and A6 to program the left side From A3 00 screen Press STOP to scroll to A4 00 A4 00 is perma...

Page 8: ...splay indicator to change water filter BREW AT TEMPERATURE DEFINITIONS DEFAULT BREW AT TEMP ON FACTORY DEFAULT FOR BREWER BREW at TEMP Batch will not start if tank temperature is below set point Displ...

Page 9: ...ing Range Increments Notes D1 Heater SSR Test Press button 2 to test button 1 stops test Activates heater Default is 10 sec Toggle OFF or ON Energizes Heater s WARNING Service use only D2 Fill Valve T...

Page 10: ...m for low supply or Flojet use E5 Brew valve flow rate 54oz 1 60L 0 42G 45 64oz 1 30 1 90Liter 0 34 0 52G 1oz 0 05L 0 013G Adjusts flow rate by brew valve E9 Dilute valve flow 86oz 2 55L 0 67G 38oz 11...

Page 11: ...low F5 Option BB Lock NO NO or YES Enables brew basket lock F8 Backup to USB Follow prompts Saves settings Insert blank USB F9 Restore From USB Applies settings from USB Insert USB Will need reboot F1...

Page 12: ...ow rate is too low Watch for short potting during brew cycle Investigate cause of low flow rate Clogged water filter 101 Error on refill Tank did not refill within expected time Water supply flow rate...

Page 13: ...ht side G15 B Rt Brews R G20 G55 component use cycles and volumes handled Available in ADVANCED counter only G5 G20 A Fill Cycles LT Hot water tank refill cycles Count Cycles of hot water tank refill...

Page 14: ...een From EXIT screen Press button 1 to toggle to the SAVE screen From SAVE screen Press button 2 to toggle to the SAVE YES screen To SAVE and EXIT Press button 1 to SAVE your changes and EXIT to OPERA...

Page 15: ...cratch surface Weekly 1 Use a commercial tea dispenser cleaner such as URNEX TABZ DIP IT or Squeak n Clean 2 Carefully Follow the instructions supplied with the cleaning product 3 Never use spray clea...

Page 16: ...supply inlet of the beverage equipment as possible 4 All beverage equipment must use a water filter A finishing carbon filter is preferred 5 Install the filter unit after a water shutoff valve and in...

Page 17: ...cified cord only from the manufacturer in order to avoid a hazard 8 Review the dimensions for the unit and verify that it will fit properly in the space intended for it Verify that the counter or tabl...

Page 18: ...or the latest versions of all information Page 18 User Guide Operator instructions P209Re0August 2021 Parts Diagrams REFERENCE 5 Above Drawing Number 1102 00457 00 Drawing Number 1101 00583 00 TBS 122...

Page 19: ...00061 00 TUBE 9 16 OD X 5 16 ID X 2 75 LG 24 1 1086 00002 00 CLAMP HOSE SIZE G NYLON 25 16 1084 00011 00 NUT CLIP ON J NUT 6 32 22 20 GA BLK PH FINISH 26 1 1001 00455 00 TOP COVER MBS TBS 1200 LARGE 2...

Page 20: ...co com for the latest versions of all information Page 20 User Guide Operator instructions P209Re0August 2021 REFERENCE 5 Above Drawing Number 1102 00457 00 Drawing Number 1101 00584 00 TBS 1222 Dual...

Page 21: ...00 TUBE DRAIN 5 8 OD X 3 8 ID X 10 LG 22 1 1025 00058 00 TUBE 9 16 OD X 5 16 ID X 25 00 LG 23 1 1025 00061 00 TUBE 9 16 OD X 5 16 ID X 2 75 LG 24 1 1086 00002 00 CLAMP HOSE SIZE G NYLON 25 16 1084 00...

Page 22: ...S 2121 7 2 1024 00062 00 GROMMET SHORT SILICONE LEVEL AND TEMP PROBE 8 1 1112 00002 00 PROBE WELDMENT WATER LEVEL 2 25 LG 9 1 1102 00161 00 PROBE ASSEMBLY TEMP AND LLC 8 LONG 10 1 1023 00362 00 FITTIN...

Page 23: ...interchangeable with 1057 00076 00 5 1 1024 00063 00 O RING 3 15 16 x 3 32 CS DASH 154 BUNA N DURO A50 NS 4 1083 00010 00 WASHER 10 SCREW W NEOPRENE BONDED SEAL NS 4 1084 00006 00 NUT 8 32 18 8 HEX M...

Page 24: ...00179 00 NUT BREW BASKET ORIFICE HOLDER 5 1 1023 00191 00 PLUG BB HANDLE GREEN NS 1 B020000G2BK Complete SQUARE Brew basket TBS 1221 t For SINGLE brewer only NS 1 B013000G2BK Complete ROUND Brew baske...

Page 25: ...e latest versions of all information Page 25 User Guide Operator instructions P209Re0August 2021 Wiring Diagram SSR T1221US 1A117 PM001 FOR SKU T1221US 1A117 PM001 T122DUS 1A117 PN00 T1221IN 1B130 PN0...

Page 26: ...Go to fetco com for the latest versions of all information Page 26 User Guide Operator instructions P209Re0August 2021 SSR FOR SKU T1221CE 1B130 PN005 CE T122DCE 1B130 PN005l CE...

Page 27: ...de 15 T61 UX120 12 Barcode 107546316 03754 Inches Lx W x H 11 25 x 8 50 x 8 50 Centimeters 28 6 x 21 6 x 21 6 Weight 14 6 lbs 6 6 kg Per Pallet 102 cases Layout 6 layers of 17 cases Weight 1 525 lbs 6...

Reviews: