F ERROR CODES
DO NOT CLEAR ERROR CODES UNTIL ERROR IS IDENTIFIED AND CORRECTED
Contact factory or specialized personnel for error codes
Code Description
Possible Cause
Corrective Action
001
Software error-error on start up or
corrupted software
Improper start-up or
shutdown
Restart , if still fault: reload software
002
Internal flash corrupted
internal data memory malfunction
Error found in cyclic
redundancy check
CRC
Restart , if still fault: reload software
If not corrected :replace board
050
Short-circuit in temperature probe
Probe failure.
Replace probe.
051
Open temperature probe.
Bad probe connection, or
probe failure.
Check all connections. Replace probe if
necessary.
100
Initial Fill Error.
Initial fill time took longer than
expected after powering up.
Water supply flow rate is
too low.
Watch for short potting during brew
cycle. Investigate cause of low flow rate.
(Clogged water filter...)
101
Error on refill-.
Tank did not refill within expected time.
Water supply flow rate is
too low.
Watch for short potting during brew
cycle. Investigate cause of low flow rate.
(Clogged water filter…)
200
Heating flatline-Tank is boiling
Heater is on, temperature is
not rising/dropping
High elevation correction. Bad heaters
or temperature probe or position
201
Heater open, high limit thermostat, or
Solid State Relay (SSR) fault
Failure of heating element,
SSR, high limit
Check and replace heating elements,
SSRs, high limit devices if necessary.
202
Heater Shorted or Stuck SSR
Heater is off and heating
SSR is stuck “ON”
Check ohms on heater (15-
60Ω). SSR
may be stuck in ON mode-replace SSR.
255
Keyboard [HID] error
Usually from longer than 10
se contact. Or faulty
reassembly after service
Restart , if still fault: reload software. If
mechanical: replace module
NO
BSKT
Insert Brew Basket
Brew basket must be in
place
This is a
SAFETY FEATURE
Insert brew basket into brewer rails to
enable brewer