Fetco TEAVARIS PLUS TBS-1221 Users Manual And Operator Instructions Download Page 17

Go to fetco.com for the latest versions of all information         

Page 17

      

User Guide & Operator instructions

  

P209

Re0

August 2021

 

Installation safety and hygiene directions-For International and CE equipment 

 

1.  Access to the service area is restricted to persons having safety/hygiene knowledge and practical experience of the 

brewer.  This appliance must be installed in locations where it can be overseen by trained personnel. 

2.  For proper operation, this appliance must be installed indoors where the temperature is between 10°C/50°F to 35°C/95°F.  

Drain and remove all liquid from equipment and lines if exposed to freezing temperatures.  

3.  All commercial cooking equipment, including this unit, is not intended for use by children or persons with reduced physical, 

sensory, or mental capabilities.  Ensure proper supervision of children and keep them away from the unit. 

4.  Children should be supervised to ensure that they do not play hot beverage equipment. 

5.  This unit must be installed and serviced by qualified personnel only. 

6.  Installation must conform to all local electrical and plumbing codes. Installation by unqualified personnel will void the unit 

warranty and may lead to electric shock or burn, as well as damage to unit and/or its surroundings.  

7.  If the power cord requires repair or replacement-it must be performed by the manufacturer or authorized service personnel 

with the specified cord only from the manufacturer in order to avoid a hazard. 

8.  Review the dimensions for the unit and verify that it will fit properly in the space intended for it.  Verify that the counter or 

table will support the total weight of the brewer and dispensers when filled (See: Technical Data). 

9.  Place the brewer on the counter or stand. When the brewer is in position, level it front to back as well as side-to-side by 

adjusting the legs. 

10. Brewers will need a sturdy supported surface for operation.  Do not move brewers when filled. 

11. Do not tilt appliance more than 10° to insure safe operation.  

12. Unit is for protected indoor use only.  Do not steam clean or use excessive water on unit.   

13. This unit is not “jet-proof” construction. Do not pressure wash or use jet spray to clean this unit.  

14. The unit is not waterproof-do not submerge or saturate with water.  

    Equipment exposed to flood and contaminated must not be used due to electrical and food safety

   

Do not operate if unit has been submerged or saturated with water.    

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WIRING METHODS: 

REFERENCE ONLY: SEE THE WIRING DIAGRAM AT BACK OF THIS GUIDE

 

TBS-1221/1222 120-volt models with cord and plug

 

TBS-1221/1222 models 200-240 volt L1, L2,G  

    

 

Electrical installation and service is to be made only by licensed electrician.  

Disconnect equipment from power supply before service.  Equipment may be  powered even if power switch is “OFF”

 

 

 

 

Labels and 

warnings for hot 

beverage 

equipment 

 

For BACK PANEL 

of equipment 

(1046.00035.00

For 200 -240 volt application: connection 

NEMA PLUG  

CONFIGURATION 

 

 

 

 

NEMA 5-15P 

           

 

 

 

                  W 

Brewer supplied by factory as 120VAC 

Summary of Contents for TEAVARIS PLUS TBS-1221

Page 1: ...d Tea Brewer FETCO TEAVARIS PLUS Commercial Beverage Equipment TBS 1221 Single Dilution Teavaris Plus TBS 1222 Dual Dilution Teavaris Plus Shown with ITD dispensers not included CONTACT INFORMATION FE...

Page 2: ...es Electrical Specifications for single domestic 120 volt cord and plug SKU Dilution Electrical Connection Heater Configuration Voltage KW Amp Draw Est 3gal Batches Hour T1221US 1A117 PM001 Domestic S...

Page 3: ...n a receiving dispenser for the left or right side brew orientation TBS 1221 Single dilution has a square brew basket and is only positioned in the center for three recipes A1 A2 and A3 Two position b...

Page 4: ...ze and then display digital process notifications 3 After Initialization STOP Lamp turns on 4 Quickly press STOP button no need to hold When brewer is In PROGRAMMING MODE the screen will display BATCH...

Page 5: ...kup to USB G5 Choose Counter A17 Dilute Mode B6 Units of Volume D13 LED Brightness F9 Restore from USB G10 Brewer Volume LT A17 Dilute Delay B7 Customers Name F10 Restore Defaults G11 Brewer Volume R...

Page 6: ...after brew to begin dilution Often used to add sweetener A172 Dilution Volume 308 oz 9 1 liters 2 4 gallons 1 512oz 0 00 15 15 liters 0 00 4 0 gallons 1 oz 0 05L 0 01G Unit default is fluid ounces Can...

Page 7: ...ess STOP to scroll through more sections See SAVE EXIT on page 5 or 14 For TBS 1222 only proceed to A4 A5 and A6 to program the left side From A3 00 screen Press STOP to scroll to A4 00 A4 00 is perma...

Page 8: ...splay indicator to change water filter BREW AT TEMPERATURE DEFINITIONS DEFAULT BREW AT TEMP ON FACTORY DEFAULT FOR BREWER BREW at TEMP Batch will not start if tank temperature is below set point Displ...

Page 9: ...ing Range Increments Notes D1 Heater SSR Test Press button 2 to test button 1 stops test Activates heater Default is 10 sec Toggle OFF or ON Energizes Heater s WARNING Service use only D2 Fill Valve T...

Page 10: ...m for low supply or Flojet use E5 Brew valve flow rate 54oz 1 60L 0 42G 45 64oz 1 30 1 90Liter 0 34 0 52G 1oz 0 05L 0 013G Adjusts flow rate by brew valve E9 Dilute valve flow 86oz 2 55L 0 67G 38oz 11...

Page 11: ...low F5 Option BB Lock NO NO or YES Enables brew basket lock F8 Backup to USB Follow prompts Saves settings Insert blank USB F9 Restore From USB Applies settings from USB Insert USB Will need reboot F1...

Page 12: ...ow rate is too low Watch for short potting during brew cycle Investigate cause of low flow rate Clogged water filter 101 Error on refill Tank did not refill within expected time Water supply flow rate...

Page 13: ...ht side G15 B Rt Brews R G20 G55 component use cycles and volumes handled Available in ADVANCED counter only G5 G20 A Fill Cycles LT Hot water tank refill cycles Count Cycles of hot water tank refill...

Page 14: ...een From EXIT screen Press button 1 to toggle to the SAVE screen From SAVE screen Press button 2 to toggle to the SAVE YES screen To SAVE and EXIT Press button 1 to SAVE your changes and EXIT to OPERA...

Page 15: ...cratch surface Weekly 1 Use a commercial tea dispenser cleaner such as URNEX TABZ DIP IT or Squeak n Clean 2 Carefully Follow the instructions supplied with the cleaning product 3 Never use spray clea...

Page 16: ...supply inlet of the beverage equipment as possible 4 All beverage equipment must use a water filter A finishing carbon filter is preferred 5 Install the filter unit after a water shutoff valve and in...

Page 17: ...cified cord only from the manufacturer in order to avoid a hazard 8 Review the dimensions for the unit and verify that it will fit properly in the space intended for it Verify that the counter or tabl...

Page 18: ...or the latest versions of all information Page 18 User Guide Operator instructions P209Re0August 2021 Parts Diagrams REFERENCE 5 Above Drawing Number 1102 00457 00 Drawing Number 1101 00583 00 TBS 122...

Page 19: ...00061 00 TUBE 9 16 OD X 5 16 ID X 2 75 LG 24 1 1086 00002 00 CLAMP HOSE SIZE G NYLON 25 16 1084 00011 00 NUT CLIP ON J NUT 6 32 22 20 GA BLK PH FINISH 26 1 1001 00455 00 TOP COVER MBS TBS 1200 LARGE 2...

Page 20: ...co com for the latest versions of all information Page 20 User Guide Operator instructions P209Re0August 2021 REFERENCE 5 Above Drawing Number 1102 00457 00 Drawing Number 1101 00584 00 TBS 1222 Dual...

Page 21: ...00 TUBE DRAIN 5 8 OD X 3 8 ID X 10 LG 22 1 1025 00058 00 TUBE 9 16 OD X 5 16 ID X 25 00 LG 23 1 1025 00061 00 TUBE 9 16 OD X 5 16 ID X 2 75 LG 24 1 1086 00002 00 CLAMP HOSE SIZE G NYLON 25 16 1084 00...

Page 22: ...S 2121 7 2 1024 00062 00 GROMMET SHORT SILICONE LEVEL AND TEMP PROBE 8 1 1112 00002 00 PROBE WELDMENT WATER LEVEL 2 25 LG 9 1 1102 00161 00 PROBE ASSEMBLY TEMP AND LLC 8 LONG 10 1 1023 00362 00 FITTIN...

Page 23: ...interchangeable with 1057 00076 00 5 1 1024 00063 00 O RING 3 15 16 x 3 32 CS DASH 154 BUNA N DURO A50 NS 4 1083 00010 00 WASHER 10 SCREW W NEOPRENE BONDED SEAL NS 4 1084 00006 00 NUT 8 32 18 8 HEX M...

Page 24: ...00179 00 NUT BREW BASKET ORIFICE HOLDER 5 1 1023 00191 00 PLUG BB HANDLE GREEN NS 1 B020000G2BK Complete SQUARE Brew basket TBS 1221 t For SINGLE brewer only NS 1 B013000G2BK Complete ROUND Brew baske...

Page 25: ...e latest versions of all information Page 25 User Guide Operator instructions P209Re0August 2021 Wiring Diagram SSR T1221US 1A117 PM001 FOR SKU T1221US 1A117 PM001 T122DUS 1A117 PN00 T1221IN 1B130 PN0...

Page 26: ...Go to fetco com for the latest versions of all information Page 26 User Guide Operator instructions P209Re0August 2021 SSR FOR SKU T1221CE 1B130 PN005 CE T122DCE 1B130 PN005l CE...

Page 27: ...de 15 T61 UX120 12 Barcode 107546316 03754 Inches Lx W x H 11 25 x 8 50 x 8 50 Centimeters 28 6 x 21 6 x 21 6 Weight 14 6 lbs 6 6 kg Per Pallet 102 cases Layout 6 layers of 17 cases Weight 1 525 lbs 6...

Reviews: