background image

Operating Instructions 

 
Follow instructions on pages 11-13 to install electrical and plumbing utilities.  Turn on water supply. 
Turn rocker switch “ON”.  Switch is on the back of the equipment, at lower right. 
The HWB will begin filling and heating taking 15-30 minutes to complete and the READY Icon to display. 
The HWB may need to be turned “OFF” and restarted from the power switch if initial fill is too slow. 
When the READY Icon displays, the machine in operation will dispense hot water at displayed temperature. 

Equipment in now ready to use. 

NOTE: For best results-leave the HWB “ON”. FETCO hot beverage equipment is well insulated and is designed to be left 
“ON” overnight.  An optional, automatic digital power saver ECO Mode may be activated if desired

Temperature is factory set for 205°F/96°.  Setting may be changed from Programming Screens, or as below. 

Operator controls, if activated, may be accessed by touching and holding lower part of screen. 

 

-Hot water tank temperature may be selected using slider 

 

-Equipment may be turned off and on from touch screen, touch screen will display “OFF” status. 

 

Starting Screens 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Operator Access Screens 

 
 
 
 
 

 

 
 
 
 
 
 
 

 

 
 
 
 
 
 
 
If Operator Access is disabled (

+

 & 

icons are dark), temperature will display, but cannot be adjusted.  

Energy Saving “ECO” Mode may be activated by touching“140” icon.  Touch: EXIT” icon to turn off ECO Mode.

 

 

HWB-2100

© 2015 All Rights 

Reserved

 

 

  

 

Ready 

  

„

 

Heating 

  

„

 

Filling 

 

Tank Set Temp. °F 

205

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

First Screen: Unit started: 

And is  Filling and Heating 

HWB-2100

© 2015 All Rights 

Reserved

 

 

Tank Set Temp. °F 

205

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 

Hold finger on lower touch screen 

to access OPERATOR ACCESS 

SCREENS and programming menu 

screens 

HWB-2100

© 2015 All Rights 

Reserved

 

 

  

„

 

Ready 

  

 

Heating

  

 

Filling 

 

Tank Set Temp. °F 

205

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Unit “READY” to dispense        

 

Set Tank Temp. 

 

205 °F 

 

|

_____________[]_

140                    208 

 

140 

 

EXIT 

 

OFF 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

“Operator Access Controls” Are 

enabled, (the -&+ icons show)

 

 

  

   

„

 

Ready 

  

 

Heating

  

 

Filling 

 

Set Tank Temp. 

205 °F 

 

|

_____________[]_

140                    208 

 

140 

 

EXIT 

 

OFF 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Operator Access is disabled.  To 

enable, go to PROGRAMMING, 

OTHER, ALLOW EDIT TEMP 

HWB-2100

© 2015 All Rights 

Reserved

 

 

  

  

„

 

ECO 

  

 

Heating

  

 

Filling 

 

Tank Set Temp. °F 

140

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

ECO mode icon displayed 

Unit is in ECO mode after being 

idle for more than four hours 

Summary of Contents for HWB-2105 XTS

Page 1: ...on per hour heavy duty commercial hot water dispensers Table of Contents Contact Information 2 Description Features 2 Specifications 2 Electrical Rating Chart 2 Dimensions Utility Connections 3 Operat...

Page 2: ...imum Amp draw Flow Rate Per hour 5 gallon North America Configuration UL cUL NSF approved B210551 1 X 3 kW 208 240 single 2 G Terminal Block Hardwire 3 1 12 9 5 Gal 19 liters B210552 1 X 4 kW 208 240...

Page 3: ...3 Dimensions Utility Connections HWB 2105 DRG 1201 00015 00 HWB 2110 DRG 1201 00016 00...

Page 4: ...may be selected using slider Equipment may be turned off and on from touch screen touch screen will display OFF status Starting Screens Operator Access Screens If Operator Access is disabled icons ar...

Page 5: ...________ _ 140 208 140 EXIT OFF HWB 2100 2015 All Rights Reserved OFF Press and hold to turn on Press and hold to progress to control screen to right to turn on the HWB 2100 TURN POWER ON TURN POWER O...

Page 6: ...roll through the four main SERVICE menus The DOWN icon will open the FEATURE icon below Scroll through the FEATURE icon with the arrows EXIT and save changes A Menu Tree is below to show the main cate...

Page 7: ...ature Touch the screen to come out of ECO mode All FETCO commercial hot beverage equipment have well insulated hot water tanks to limit energy consumption Effective insulation increases equipment life...

Page 8: ...____ YES NO If Yes Follow directions on the touch screen OUTPUTS Programming Items Factory set Default Programming Range display Notes Fill Valve Fill Valve Test Press to test TEST Press To Test Opera...

Page 9: ...ory defaults Values displayed left are most common and generally useable Res to Factory Reset to default Reset to Default Are you sure ________________ ____ YES NO Values must re enterd as seen in Ele...

Page 10: ...drained beyond the low level sensor Check for Tank leakage water turned off EMPTY TANK OVERHEAT 114 Temp probe fault empty tank is too hot Turn equipment off allow to cool service fault restore power...

Page 11: ...requires hardwired grounded service to the terminal block illus 1 2 Verify that the actual voltage at the electrical service connection is compatible with the specifications on the equipment serial nu...

Page 12: ...nspection Operator Training Review the operating procedures with whoever will be using the equipment Pay particular attention to the following areas 1 Show the location and operation of the water shut...

Page 13: ...urn as well as damage to unit and or its surroundings 7 If the power cord requires repair or replacement it must be performed by the manufacturer or authorized service personnel with the specified cor...

Page 14: ...14 Parts and Service drawings Drawing 1101 00201 229 217 00 HWB 2105 Complete Parts...

Page 15: ...0262 00 ASSEMBLY BACK PANEL HWB 2105 CE 18 11 1082 00017 00 SCREW 6 32 X 1 2 TRUSS HD PHIL MACHINE 19 1 1046 00030 00 LABEL WARNING DISCONNECT FROM POWER SOURCE 20 2 1023 00159 00 CORNER INSERT 21 1 1...

Page 16: ...16 HWB 2110 Complete Parts Drawing 1101 00202 00...

Page 17: ...WB 2110 CE 18 11 1082 00017 00 SCREW 6 32 X 1 2 TRUSS HD PHIL MACHINE 19 1 1046 00030 00 LABEL WARNING DISCONNECT FROM POWER SOURCE 20 2 1023 00159 00 CORNER INSERT 21 1 1023 00208 00 FAUCET BODY HWB...

Page 18: ...18 HWB 2105 Hot Water Tank Drawing 1104 00072 78...

Page 19: ...0 PROBE WELDMENT WATER LEVEL 5 00 LG 12 1 1107 00034 00 HEATER ASSEMBLY IMMERSION 3000W 240VAC 12 1 1107 00035 00 HEATER ASSEMBLY IMMERSION 4000W 240VAC 13 1 1024 00007 00 O RING DASH 344 TANK COVER 1...

Page 20: ...20...

Page 21: ...ASH 344 TANK COVER 11 1 1102 00007 00 TANK COVER ASSEMBLY 12 2 1003 00140 00 ALUMINUM BRACKET FOR SSR 13 2 1052 00033 00 RELAY SOLID STATE 50A 480VAC W BUILD IN VARISTOR 14 4 1081 00042 00 STANDOFF 1...

Page 22: ...0 SPACER 6MM OD x 3 2MM ID x 5MM LG Z P 6 1 1052 00001 00 POWER SUPPLY 90 264VAC 24VDC 1 8A 7 4 1029 00012 00 SPACER 25 HEX X 1 LG FEM 4 40 THREAD 8 1 1112 00246 00 WELDMENT BRACKET TERMINAL BLOCK 3 P...

Page 23: ...D x 3 2MM ID x 5MM LG Z P 6 1 1052 00001 00 POWER SUPPLY 90 264VAC 24VDC 1 8A 7 4 1029 00012 00 SPACER 25 HEX X 1 LG FEM 4 40 THREAD 8 3 1083 00011 00 WASHER 8 SCREW SIZE INTERNAL TOOTH LOCK 9 3 1084...

Page 24: ......

Page 25: ......

Reviews: