4
Operating Instructions
Follow instructions on pages 11-13 to install electrical and plumbing utilities. Turn on water supply.
Turn rocker switch “ON”. Switch is on the back of the equipment, at lower right.
The HWB will begin filling and heating taking 15-30 minutes to complete and the READY Icon to display.
The HWB may need to be turned “OFF” and restarted from the power switch if initial fill is too slow.
When the READY Icon displays, the machine in operation will dispense hot water at displayed temperature.
Equipment in now ready to use.
NOTE: For best results-leave the HWB “ON”. FETCO hot beverage equipment is well insulated and is designed to be left
“ON” overnight. An optional, automatic digital power saver ECO Mode may be activated if desired
.
Temperature is factory set for 205°F/96°. Setting may be changed from Programming Screens, or as below.
Operator controls, if activated, may be accessed by touching and holding lower part of screen.
-Hot water tank temperature may be selected using slider
-Equipment may be turned off and on from touch screen, touch screen will display “OFF” status.
Starting Screens
Operator Access Screens
If Operator Access is disabled (
+
&
-
icons are dark), temperature will display, but cannot be adjusted.
Energy Saving “ECO” Mode may be activated by touching“140” icon. Touch: EXIT” icon to turn off ECO Mode.
HWB-2100
© 2015 All Rights
Reserved
Ready
Heating
Filling
Tank Set Temp. °F
205
First Screen: Unit started:
And is Filling and Heating
HWB-2100
© 2015 All Rights
Reserved
Tank Set Temp. °F
205
Hold finger on lower touch screen
to access OPERATOR ACCESS
SCREENS and programming menu
screens
HWB-2100
© 2015 All Rights
Reserved
Ready
Heating
Filling
Tank Set Temp. °F
205
Unit “READY” to dispense
Set Tank Temp.
205 °F
|
_____________[]_
|
140 208
140
EXIT
OFF
“Operator Access Controls” Are
enabled, (the -&+ icons show)
Ready
Heating
Filling
Set Tank Temp.
205 °F
|
_____________[]_
|
140 208
140
EXIT
OFF
Operator Access is disabled. To
enable, go to PROGRAMMING,
OTHER, ALLOW EDIT TEMP
HWB-2100
© 2015 All Rights
Reserved
ECO
Heating
Filling
Tank Set Temp. °F
140
ECO mode icon displayed
Unit is in ECO mode after being
idle for more than four hours
Summary of Contents for HWB-2105 XTS
Page 3: ...3 Dimensions Utility Connections HWB 2105 DRG 1201 00015 00 HWB 2110 DRG 1201 00016 00...
Page 14: ...14 Parts and Service drawings Drawing 1101 00201 229 217 00 HWB 2105 Complete Parts...
Page 16: ...16 HWB 2110 Complete Parts Drawing 1101 00202 00...
Page 18: ...18 HWB 2105 Hot Water Tank Drawing 1104 00072 78...
Page 20: ...20...
Page 24: ......
Page 25: ......