Error Codes 

Description  

Recommended Corrective Action for 
Service  

Remedy 

OK 0 

No 

error 

 

SOFTWARE ERROR 

There was a problem with the internal 
program 

replace board 

EE CRC WRONG 

The internal data memory malfunction 
(EE CRC)  

replace board 

TEMP SENSOR SHORT 1  50  Short circuit in temperature probe T1 

 

Check board or probe 

TEMP SENSOR OPEN 1 

51  Temperature probe circuit is open T1   Check board or probe 

TEMP SENSOR SHORT 2  50  Short circuit in temperature probe T2    Check board or probe 
TEMP SENSOR OPEN 2 

51  Temperature probe circuit is open T2    Check board or probe 

PREFILLING TOO LONG 

100 Tank initial filling is taking too long 

Water turned off, clogged filter,  
Turn equipment off, restore power, 
 clear error, and proceed 

OVER FLOW 

103 

Tank Overflow Error - May be boiling 
1-Hot water tank may be steaming or 
boiling due to altitude. 

Liquid level probe fault,  
Correct temperature set point for 
altitude, see chart page-7.  

XCHANGED 106 

The LLC probes' connectors have been 
reversed 

Turn equipment off, service probes,  
restore power, clear error, and 
proceed 

TANK WATER LEVEL IS 
TOO LOW 

107 

The tank has been drained beyond the 
low level sensor. 

Check for Tank leakage, water turned 
off. 

EMPTY TANK OVERHEAT  114 

Temp. probe fault - empty tank is too 
hot 

Turn equipment off, allow to cool, 
service fault, restore power, clear 
error, and proceed 

TEMP 

100C 115 

Temp.probe fault –  
the temp is above water boiling point.   
Possible bad probe 

Turn equipment off, allow to cool, 
service fault, restore power, clear 
error, & proceed 

WATER BOILING 

200 

e.g. user set temp 90°C  & water boils 
at 85°C 

Check probe position, check heaters 
Also see  Error Eode 103-above 

HEATER OPEN 

201 Heater circuit is open 

Heater open, high limit thermostat,  

SSR SHORTED 

202 

The Solid State Relay failed  
(short circuit) 

Solid State Relay (SSR) fault  

POWER CYCLE NEEDED  254 

Machine needs to be power cycled to 
write new values to the EEPROM 
memory 

Power cycle the machine  
(Turn OFF-Then ON) 
 

TOUCH SCREEN 

255 

A problem with the LCD Touch Screen, 
touched too long (>2 min) 

Power cycle the machine  
(Turn OFF-Then ON) 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Display Inputs 
(See “INPUTS” 
Service Screen)

 

Level probe  Low

 

Level probe  High

 

Temp. Probe 1

 

Temp. Probe 1

 

Temp. Probe 2

 

Temp. Probe 2

 

SD Card present

 

Float Switch

 

 

 

„

 

„

 

†

 

215F

 

„

 

158F

 

†

 

„

 

 

Use  DISPLY INPUTS screen to assist in error code fault correction.  

There are two Temp.Probes shown as Temp Probe1&2  Temp Probe1 is 

the Hot Water Tank  Temp Probe  2 is the overflow sensor probe 

Summary of Contents for HWB-2105 XTS

Page 1: ...on per hour heavy duty commercial hot water dispensers Table of Contents Contact Information 2 Description Features 2 Specifications 2 Electrical Rating Chart 2 Dimensions Utility Connections 3 Operat...

Page 2: ...imum Amp draw Flow Rate Per hour 5 gallon North America Configuration UL cUL NSF approved B210551 1 X 3 kW 208 240 single 2 G Terminal Block Hardwire 3 1 12 9 5 Gal 19 liters B210552 1 X 4 kW 208 240...

Page 3: ...3 Dimensions Utility Connections HWB 2105 DRG 1201 00015 00 HWB 2110 DRG 1201 00016 00...

Page 4: ...may be selected using slider Equipment may be turned off and on from touch screen touch screen will display OFF status Starting Screens Operator Access Screens If Operator Access is disabled icons ar...

Page 5: ...________ _ 140 208 140 EXIT OFF HWB 2100 2015 All Rights Reserved OFF Press and hold to turn on Press and hold to progress to control screen to right to turn on the HWB 2100 TURN POWER ON TURN POWER O...

Page 6: ...roll through the four main SERVICE menus The DOWN icon will open the FEATURE icon below Scroll through the FEATURE icon with the arrows EXIT and save changes A Menu Tree is below to show the main cate...

Page 7: ...ature Touch the screen to come out of ECO mode All FETCO commercial hot beverage equipment have well insulated hot water tanks to limit energy consumption Effective insulation increases equipment life...

Page 8: ...____ YES NO If Yes Follow directions on the touch screen OUTPUTS Programming Items Factory set Default Programming Range display Notes Fill Valve Fill Valve Test Press to test TEST Press To Test Opera...

Page 9: ...ory defaults Values displayed left are most common and generally useable Res to Factory Reset to default Reset to Default Are you sure ________________ ____ YES NO Values must re enterd as seen in Ele...

Page 10: ...drained beyond the low level sensor Check for Tank leakage water turned off EMPTY TANK OVERHEAT 114 Temp probe fault empty tank is too hot Turn equipment off allow to cool service fault restore power...

Page 11: ...requires hardwired grounded service to the terminal block illus 1 2 Verify that the actual voltage at the electrical service connection is compatible with the specifications on the equipment serial nu...

Page 12: ...nspection Operator Training Review the operating procedures with whoever will be using the equipment Pay particular attention to the following areas 1 Show the location and operation of the water shut...

Page 13: ...urn as well as damage to unit and or its surroundings 7 If the power cord requires repair or replacement it must be performed by the manufacturer or authorized service personnel with the specified cor...

Page 14: ...14 Parts and Service drawings Drawing 1101 00201 229 217 00 HWB 2105 Complete Parts...

Page 15: ...0262 00 ASSEMBLY BACK PANEL HWB 2105 CE 18 11 1082 00017 00 SCREW 6 32 X 1 2 TRUSS HD PHIL MACHINE 19 1 1046 00030 00 LABEL WARNING DISCONNECT FROM POWER SOURCE 20 2 1023 00159 00 CORNER INSERT 21 1 1...

Page 16: ...16 HWB 2110 Complete Parts Drawing 1101 00202 00...

Page 17: ...WB 2110 CE 18 11 1082 00017 00 SCREW 6 32 X 1 2 TRUSS HD PHIL MACHINE 19 1 1046 00030 00 LABEL WARNING DISCONNECT FROM POWER SOURCE 20 2 1023 00159 00 CORNER INSERT 21 1 1023 00208 00 FAUCET BODY HWB...

Page 18: ...18 HWB 2105 Hot Water Tank Drawing 1104 00072 78...

Page 19: ...0 PROBE WELDMENT WATER LEVEL 5 00 LG 12 1 1107 00034 00 HEATER ASSEMBLY IMMERSION 3000W 240VAC 12 1 1107 00035 00 HEATER ASSEMBLY IMMERSION 4000W 240VAC 13 1 1024 00007 00 O RING DASH 344 TANK COVER 1...

Page 20: ...20...

Page 21: ...ASH 344 TANK COVER 11 1 1102 00007 00 TANK COVER ASSEMBLY 12 2 1003 00140 00 ALUMINUM BRACKET FOR SSR 13 2 1052 00033 00 RELAY SOLID STATE 50A 480VAC W BUILD IN VARISTOR 14 4 1081 00042 00 STANDOFF 1...

Page 22: ...0 SPACER 6MM OD x 3 2MM ID x 5MM LG Z P 6 1 1052 00001 00 POWER SUPPLY 90 264VAC 24VDC 1 8A 7 4 1029 00012 00 SPACER 25 HEX X 1 LG FEM 4 40 THREAD 8 1 1112 00246 00 WELDMENT BRACKET TERMINAL BLOCK 3 P...

Page 23: ...D x 3 2MM ID x 5MM LG Z P 6 1 1052 00001 00 POWER SUPPLY 90 264VAC 24VDC 1 8A 7 4 1029 00012 00 SPACER 25 HEX X 1 LG FEM 4 40 THREAD 8 3 1083 00011 00 WASHER 8 SCREW SIZE INTERNAL TOOTH LOCK 9 3 1084...

Page 24: ......

Page 25: ......

Reviews: