Programming 

 

 

Batch Settings 

Display 

 

 

Turn the brewer off by pressing the power switch. 

 

 

 

 

Press and hold the power switch until the display reads 

P r G

P r G 

 

The left side 

STOP 

button will illuminate. 

 

 

 

 

Quickly press the 

STOP

 button.  

      

 

 

 

The display will show the software version.   Example: 

0.0  03.L 

 

 

 

Press 

STOP 

to continue. 

 

 

 

 

Batches are numbered 1 – 2 (single side) or 1 – 4 (dual side) 

 

 

                   

 

 

 

Next, the first batch parameter is displayed – batch 1, brew volume  

1.1  1.00 

 

       Use the 

SCROLL UP

 and 

SCROLL DOWN

 buttons to adjust. 

 

 

       Press the 

STOP

 button to go to the next parameter – brew time. 

1.2  4.00 

 

 

 

Continue this way until all parameters are programmed for batch #1. 
(See the chart below for an explanation of each parameter.) 

 

 

 

 

Next, batch #2 programming begins. 

2.0  OFF 

 

       Batches 2 and 4 may be disabled by leaving them set to 

“OFF”. 

 

      Change to 

“ON”

 to enable.  Batches 1 and 3 cannot be disabled. 

 

 

 

 

After all batches are programmed, go to temperature settings. 

7      200 

 

(See next page) 

 

 

 

 

Important!

 After programming, you must press and hold the 

STOP

 button until the display reads 

STO

 to save the 

settings and exit programming mode, or changes will be lost.  You may exit programming at any time. 

 
Batch Parameters

 

 

      

X=Batch Number (1 - 4) 

Parameter Name 

Range 

Increment Default 

Setting 

Comment 

X.0 

Batch Enabled or 
Disabled 

On/Off 

 

Batch 1 & 3 = ON 
Batch 2 & 4 = OFF 

Batch 1 & 3 cannot 
be disabled. 

X.1 Brew 

Volume: 

 

 

 

 

CBS-2031ee/2032ee  0.94 – 4.72 

0.01 

2.49 liters 

 

CBS-2041ee/2042ee  0.25 – 1.25 

0.01 

1.0 gallons 

To change setting to 
liters or gallons, see 
# 59 in Advanced 
Settings section. 

X.2 

Brew Time (Min:Sec)  2:00 – 9:30 

0:30 

4:00 minutes 

 

X.4 

Prewet Percent 

0.00 – 15.0% 

1% 

0 % 

Percentage of total 
brew volume 

X.5 Prewet 

Delay 

(Min:Sec)

 

0:10 – 5:00 

0:10 

1:00 minute 

The time between 
prewetting and start 
of brew cycle. 

X.6 

Drip Delay (Min:Sec) 

 

 

 

 

CBS-2031ee/2032ee  0:30 – 6:00 

0:10 

1:00 minute 

 

CBS-2041ee/2042ee  0:30 – 6:00 

0:10 

1:30 minute 

The time between 
end of brew cycle 
and unlocking of 
brew basket. 

1.1   1.00

PARAMETER

SETTING

BATCH # 

Example: Left Side – Large Batch – Volume 1.0 Gal.

Summary of Contents for CBS-2031ee

Page 1: ...ntents Contact Information 2 Description Features 2 Specifications 2 Requirements 2 Weights and Capacities 2 Electrical Configuration and Brewing Efficiency 3 Dimensions Utility Connections 4 Installa...

Page 2: ...les Within these cycles the software calculates how long to spray water over the coffee grounds and how long to pause before the next cycle begins Features Two fully programmable batch sizes per side...

Page 3: ...08 single 3 ground 4 6 22 4 14 6 22 0 120 220 5 1 23 7 16 3 22 0 120 240 6 1 25 8 19 4 22 0 CBS 2041ee 1 0 gallon per batch Electrical Heater Voltage Maximum Batches per Hour max 11 Config Code Config...

Page 4: ...4 Dimensions Utility Connections CBS 2031ee DWG 201141 000 CBS 2032ee DWG 201142 000...

Page 5: ...5 CBS 2041ee DWG 201143 000 CBS 2042ee DWG 201144 000...

Page 6: ...coffee dispenser s Place the brewer on its back and screw in the legs 3 Place the brewer on the counter or stand 4 When the brewer is in position level it front to back as well as side to side by adj...

Page 7: ...per fill levels The brewer is factory set with water only no coffee to dispense the correct amount of water If the actual volume is slightly different from the programmed volume fine tuning the brewer...

Page 8: ...urn the power switch on 2 Prepare a brew basket with the correct size filter and appropriate amount of coffee 3 Slide the brew basket completely into the rails 4 Place a clean empty preheated dispense...

Page 9: ...erature settings 7 200 See next page Important After programming you must press and hold the STOP button until the display reads STO to save the settings and exit programming mode or changes will be l...

Page 10: ...Range Default Comment 50 Water Level in Tank 0 1 Tests if water is touching probe 0 Tank is less than full 1 Tank is full 51 Water Resistance K 0 200 Displays the electrical resistance of the water in...

Page 11: ...d and the switch light will go out Brew switches are named S1 S2 S3 etc The left STOP switch must be pressed last as this will exit the test 65 Relay Test 0 Tests the individual relays that control va...

Page 12: ...nds Possible leak in tank fitting or valve Check inside of machine for leaks 102 Unwanted Fill When brewer is idle the fill valve was activated for more than 30 seconds during a 1 hour period Water su...

Page 13: ...found on our web site http www fetco com Cleaning Maintenance Daily Wipe the area above the brew baskets to remove coffee residue Daily or Weekly Clean the Cascading Spray Domes with a soft brush and...

Page 14: ...14 Parts Figure 1 CBS 2031ee Main Assembly DWG 101269 B...

Page 15: ...22 4 73029 LEG THERMOPLASTIC 2 50 63mm 23 1 104094 ASSEMBLY TANK CBS 2031ee O RING FITTINGS SEE FIG 2 24 1 22125 INSULATION TANK FRONT CBS 2031ee 25 1 22063 INSULATION TANK BACK CBS 2031e 26 1 45097...

Page 16: ...HOSE ID 8 1 24098 O RING 9 16 X 3 4 3 32 WIDTH 9 1 13135 NUT FOR 1 2 HOSE ID FITTING 10 3 83084 WASHER 875 OD X 536 ID FLA 22 GA 11 2 25098 FITTING COMPRESSION MALE CONNECTOR 12 1 25128 FITTING 90 DE...

Page 17: ...17 Figure 3 CBS 2032ee Main Assembly DWG 101270 B...

Page 18: ...8 MPT 25 1 86040 CONNECTOR CABLE CLAMP 3 4 26 1 54026 PROBE TEMPERATURE 5 LONG 50k 27 1 K028 WATER LEVEL PROBE REPLACEMENT CBS 2030 S 28 2 102195 ASSEMBLY BUMPER 2030e 29 1 25140 TUBE 5 8 OD X 3 8 ID...

Page 19: ...FITTING 1 2 HOSE ID 9 1 24098 O RING 9 16 X 3 4 3 32 WIDTH 10 1 13135 NUT FOR 1 2 HOSE ID FITTING 11 4 83084 WASHER 875 OD X 536 ID FLA 22 GA 12 2 25098 FITTING COMPRESSION MALE CONNECTOR 13 2 25128...

Page 20: ...20 Figure 5 CBS 2041ee Main Assembly DWG 101272 B...

Page 21: ...078 FITTING S 53 FILL VALVE INLET 23 1 03074 BRACKET S 53 24 4 82020 SCREW S 53 FILL VALVE 25 1 31031 FITTING 90 MALE ELBOW 3 8 TUBE OD X 3 8 MPT 26 1 86040 CONNECTOR CABLE CLAMP 3 4 27 1 51089 0BOARD...

Page 22: ...HOSE ID 8 1 24098 O RING 9 16 X 3 4 3 32 WIDTH 9 1 13135 NUT FOR 1 2 HOSE ID FITTING 10 3 83084 WASHER 875 OD X 536 ID FLA 22 GA 11 2 25098 FITTING COMPRESSION MALE CONNECTOR 12 1 25128 FITTING 90 DE...

Page 23: ...23 Figure 7 CBS 2042ee Main Assembly DWG 101271 B...

Page 24: ...TROL 100 120VAC DUAL 23 8 29007 NUT 4 40 KNURLED THUMB 24 3 73002 LEG FLANGE FOOT 4 HIGH 25 1 45100 OVERLAY CBS 2042ee 26 1 44004 LABEL GROUND 27 1 K029 WATER LEVEL PROBE REPLACEMENT CBS 2040 S 50 S 2...

Page 25: ...FITTING 3 8 HOSE ID 9 1 24098 O RING 9 16 X 3 4 3 32 WIDTH 10 1 13135 NUT FOR 1 2 HOSE ID FITTING 11 4 83084 WASHER 875 OD X 536 ID FLA 22 GA 12 2 25098 FITTING COMPRESSION MALE CONNECTOR 13 2 25128...

Page 26: ...HANDLES PART DESCRIPTION 23169 BREW BASKET HANDLE RED 23171 BREW BASKET HANDLE GREEN ITEM QTY PART DESCRIPTION 1 1 09021 WIRE INSERT 13 X 5 2 2 82118 HANDLE SCREW 3 1 23074 BREW BASKET HANDLE BLACK 4...

Page 27: ...20 VAC CSD 3 6 Part 102357 ITEM QTY PART DESCRIPTION 1 1 102378 ASSEMBLY HOUSING SPRAY W MAGNETS CSD DIA 3 6 2 1 24075 O RING 801 ID X 1 16 CROSS SEC 3 1 102214 ASSEMBLY DISPENSE VALVE RPE 120V 60Hz 4...

Page 28: ......

Reviews: