C SERVICE INPUTS
Brewer Sensors and Keypad
POSITION Program Items
Factory set Default Programming
Range Increments
Notes
C1
LLC Probe
continuity
Direct read
Reading of tank
water resistivity in
TDS
≈
850- LOW
≈
1600-HIGH
Nominal values
C2
Brew Basket
Sensor
Direct read
YES or NO
C3
Tank
Temperature
Direct read
Hot water tank
temperature
Actual
values
C4 USB
Drive
NO
C5 Keyboard
Test
Calibrate
Checks buttons
under membrane
cover
YES/NO
Follow directions on
the touch screen
.
D SERVICE OUTPUTS
Test Valves and Heaters; Set screen brightness
POSITION Program Items
Factory set Default
Programming
Range
Increments Notes
D1
Heater SSR
Test
Press button 2 to test
(button 1 stops test)
Activates heater
Default is 10 sec..
/-
OFF or ON
Energizes Heater(s)
WARNING!
Service use only.
D2
Fill Valve Test
Press button 2 to test
(button 1 stops test)
Activates valve
Default is 10 sec.
/-
OFF or ON
Press To Test
D4
Brew Valve Test (Press to test)
Activates valve
Default is 10 sec.
/-
OFF or ON
Runs valve to verify flow.
NOTE: Have container
under brew basket.
Single series displays right side only Left Valve display is only for twin side brewer.
D9 LCD
Brightness
Brightness=90%
20-100%
5%
Adjust LCD screen
brightness only-Not for
LEDs under buttons
D10 LED
Brightness
Brightness=60%
20-100%
5%
Adjust LED button
brightness only-Not for
the screen display LCD
.
E CALIBRATION
Brewer Sensors and Keypad
POSITION Program Items
Factory set Default Programming
Range
Increments
Notes
E1
Ready Temp.
Offset
-4°F
-2°C
-2° to -10°F
-1° to -5° C
1°F
1°C
Compensates output to
measured temperature
E2 LLC
Sensitivity
NORMAL
(“NORMAL” for most
water)
HIGH
(Biased for reverse
osmosis water or
very pure water)
NORMAL
HIGH
Liquid level control
sensitivity.
High,1300
Ω
is for reverse
osmosis water or very
pure water.
E3
Slow flow rate
from mains
OFF OFF/ON
/-
YES or NO
Trims fill system for low
supply
E5
RIGHT brew
valve flow rate:
1.60L/0.42G
1.30-1.90Liter
0.34-0.52G
0.05L
0.013G
Adjusts flow rate
Use this formula to compensate for minor discrepancies in actual volume versus programmed volume.
Default Brew Valve Flow Rate—All CBS-1200 Brewers
CBS-1220
L/min
Range
Right Brew Valve FR
1.60
+1.3 L to 1.9 L
Use the formula above to determine the correct setting
Set lower to increase volume, higher to decrease volume.
See “PROGRAM” E5 For valve settings and calibration. Factory set brew valve flow rates are in liter/min