Go to fetco.com for the latest versions of all information
Page 4
User Guide & Operator instructions
P194
Re0
January 2021
Programing Menu Layout
A10 to A70
B10-B40
C10-C50
D10-D90
E10-E70
F10-F120
G1-G15
H10-H11
Batch Parameters
General Settings
Service Inputs
Service Outputs
Calibration
Service Menu
Counters
Exit and Save
|
|
|
|
|
|
|
|
A11
Brew Volume
B1
Tank Temperature
C1
LLC Probe
D1
Heater SSR
E1
Ready Temp. Offset
F1
Firmware Ver.
G1
Filter Used
H1
Save Changes
|
|
|
|
|
|
|
|
A12
Brew Time
B2
Brew at Temp
C2
Basket Sensor
D2
Fill Valve
E2
LLC Sensitivity
F2
Bootloader Ver.
G2
Filter Life
H2
EXIT?
|
|
|
|
|
|
|
A13
Prewet Percent
B3
Show Tank Temp
C4
Tank Temperature
D4
Brew Valve
E3
Slow Flow Compensate
F3
Select Model
G3
Filter Reset
|
|
|
|
|
|
|
A14
Prewet Delay
B4
Units of Temp
C5
USB Drive
D8
Basket Lock
E5
Brew Flow
F5
Option BB Lock
G4
Counter Reset
|
|
|
|
|
|
A16
Drip Delay
B5
Units of Volume
C6
Keyboard Test
D12
LCD Brightness %
F8
Backup to USB
G5
Choose Counter
|
|
|
|
|
A20
Batch (2) Enabled
B6
Customer Name
D13
LED Brightness %
F9
Restore from USB
G10
Brewer Volume
[LT]
|
|
|
|
A21
Brew Volume
B7
Customers Name
F10
Restore Defaults
G11
Brewer Volume [R]
|
|
|
|
A22
Brew Time
B8
Demo Mode
F11
Error Log
G14
Rt Brews [LT]
|
|
|
|
A23
Prewet Percent
B9
Eco Mode
F12
Erase Error Log
G15
Rt Brews [R]
|
|
|
A26
Drip Delay
B10
Eco Idle Time
F13
Service Phone#
|
|
|
A30
Batch (3) Enabled
B11
Eco Idle Temp
F15
Override Rt BBS
|
|
A90
Copy Batch
F17
Override Rt BBL
|
A91
Copy Batch: From
|
A92
PASTE: To
The A menus [A1-3] correspond to batch buttons [1-3] on the touch panel
Access the A menus to PROGRAM & make changes to individual menu recipes. Menu settings can be copied
Menu position A1 is permanent. Menus A2, A3 can be removed by operator if desired
From A PRG screen
Press button 1 to go
to the A menu access
screen
From A11 screen
Press
STOP
to scroll to
A20.
(A1 is permanent)
From A20 screen
Press STOP to
scroll to the third
batch in the “A”
menus. Make any
changes as required
From A30 screen
Press STOP to scroll
through COPY and
further to remaining
programming keys.
To continue
Press STOP to scroll
through sections
See SAVE & EXIT in
previous table
.
RECIPE Location map
View and change settings for the brew recipes from the “A” screens with
the controls in PROGRAMMING.
The batch A1 position is permanent and cannot be disabled
To access programming steps A20 and A30
Batch programming steps A20 or A30 will not display from step A10
Programming for steps A20 and A30 are accessed from any step in A10
by pressing the STOP button (1x for A20;2x for A30).
DISPLAY
STOP BATCH
A1
(permanent)
BATCH
A2
BATCH
A3
STOP
Batch Program
A
STOP
BREW VOLUME
A11
2.20L +/-
STOP
Batch Enabled
A20
YES-
STOP
Batch Enabled
A30
YES -
STOP
General Settings
B-
STOP
Batch Program
A