11
Belt sander
Technical data
BS 105/BS 105 E
Power consumption
1000/1200 W
Sanding belt
width
105 mm
length
620 mm
Sanding speed
no load
380/230-380 m/min
Rated load
320/170-340 m/min
Weight according to
EPTA-Procedure 01:2014
6.3 kg
The specified illustrations can be found at the
beginning of the operating instructions.
Graphical symbols
Caution. Danger!
Read the operating instructions/notes
Wear ear protection!
Wear a dust mask!
Wear protective goggles!
Wear protective gloves!
Safety class II
Do not dispose of it with domestic waste.
1
Safety warnings
1.1
General power tool safety warnings
WARNING!
Read all safety warnings,
instructions, illustrations and specifica-
tions provided with this power tool.
Failure to
follow all instructions listed below may result in
electric shock, fire and/or serious injury.
Save all warnings and instructions for future
reference.
The term „power tool“ in the warnings refers
to your mains-operated (corded) power tool or
battery-operated (cordless) power tool.
1.2
Tool-specific safety rules
-
Hold the power tool by insulated gripping sur-
faces, because the sanding surface may contact
its own cord.
Cutting a “live” wire may make
exposed metal parts of the power tool “live” and
could give the operator an electric shock.
-
Use clamps or another practical way to secure
and support the workpiece to a stable platform
- mainly in case of grinding small pieces
. Hold-
ing the work by your hand or against the body
leaves it unstable and may lead to loss of control.
Wear suitable personal protection
equipment: ear protection to re-
duce the risk of damaging your
hearing; protective goggles; pro-
tective gloves when handling
tools and coarse materials.
- Harmful/toxic dusts can occur during your work
(e.g. lead-containing paint, some types of wood).
Contact with these dusts, especially inhaling
them, can represent a hazard for operating
personnel or persons in the vicinity. Comply with
the safety regulations that apply in your country.
Connect the electric power tool to a suitable
extraction system. To protect your health, wear
a P2 protective mask.
- The manufacturer’s handling and processing
instructions must be observed without fail if
explosive or self-igniting dusts are likely to oc-
cur during sanding.
- Before doing any work to the machine, first re-
move the plug from the mains.
- Only insert plug when machine is switched off.
- Use the machine only for dry sanding.
- Materials containing asbestos are not to be
worked.
- Always connect to a dust bag or external dust
extraction device.
- When sanding take care the cable does not come
into contact with the sanding belt.
- Check the plug and the cable regularly in order
to prevent a hazard. In the event of damage,
these must be replaced by an authorised service
workshop only.
- Do not use torn or damaged sanding belts.
-
Only for AS/NZS:
The tool shall always be sup-
plied via residual current device with a rated
residual current of 30 mA or less.
1.3
Emission levels
Typically, the noise levels that are determined in
accordance with EN 62841 (see EC declaration of
conformity) are as follows:
Sound pressure level
L
PA
= 87 dB(A)
Sound power level
L
WA
= 98 dB(A)
Uncertainty
K = 3 dB