26
Festo — VTOP — 2021-07
Technical data
13.2
Adapter plate VABA-C13-100 -...- F90-G12
VABA-C13-100-...
-1-F90-G12
-2-F90-G12
Design
Sub base valve
Function
Interface between valve terminal VTOP, pneumatic actuator and
positioner
Ambient temperature
[°C]
–40 … +80
Transport and storage
temperature
[°C]
–40 … +80
Pneumatic port 1
G1/2
Pneumatic port 3
G1/2
Operating medium
Compressed air to ISO 8573-1:2010 [7:7:–]
Inert gas
Information on operating
medium
Lubricated operation not possible
Medium temperature
[°C]
–40 … +80
Operating pressure
[MPa]
0 … 0.9
[bar]
0 … 9
[psi]
0 … 130.5
CE marking
See declaration of conformity
Product weight
[g]
2225
3140
Tab. 10: Technical data – Adapter plate VABA-C13-100 -...- F90-G12