13
Technical data
13.1
Valve terminal VTOP
Valve terminal VTOP
Design
Modular valve terminal
Mounting position
Any
Ambient temperature
[°C]
–40 … +80
–20 … +80 (fail-safe module VOGI)
Transport and storage
temperature
[°C]
–40 … +80
–20 … +80 (fail-safe module VOGI)
Operating medium
Compressed air to ISO 8573-1:2010 module-dependent
Inert gas
Operating pressure
[MPa]
0 … 0.9 module-dependent
[bar]
0 … 9 module-dependent
[psi]
0 … 130.5 module-dependent
CE marking
See declaration of conformity
Corrosion protection
CRC3
1)
Vibration resistance
in accordance with
DIN EN 60068-2-6
±0.15 mm path at 10 … 58 Hz
2 g acceleration at 58 … 150 Hz
Shock resistance
in accordance with
DIN EN 60068-2-27
± 15 g at 11 ms duration;
5 shocks per direction
Continuous shock resist-
ance in accordance with
DIN EN 60068-2-29
± 10 g at 11 ms duration;
1000 shocks per direction
1) High corrosion stress. Outdoor exposure under moderate corrosive conditions. External visible parts in direct contact with the
ambient atmosphere typical for
industrial applications or media such as solvents and cleaning agents, with primarily functional requirements for the surface.
Tab. 9: Technical data – Valve terminal VTOP