SFE1−LF−...
Festo SFE1−LF−... 0503NH English
41
S
y
m
bol
s
D
e
sc
ription
Running light (1 segment): Consumption measurement for Out A
active
3 segments flash: Hysteresis value will be displayed
2 segments flash:
Minimum/maximum value will be reset
1 segment flashes:
Segment 6:
Switching point SP or SP.Lo will be displayed
Segment 8:
Switching point SP.Hi will be displayed
Segment 1:
Min. flow (F.Lo) will be displayed
Segment 10: Max. flow (F.Hi) will be displayed
Prep
a
rin
g
c
o
mm
i
ss
ionin
g
The basic status is called the RUN mode. This shows the current measured value.
Can be reached from other modes by:
pressing the the EDIT button for 3 s or
when a monitoring time expires (timeout see section 12. Menu structure
S
Switch on the operating voltage. The SFE1−LF−... is now in the RUN mode.
S
Check the settings of the SFE1−LF−... .
Ple
as
e note
An overview of the menu structure can be found in section 12.
RUN
m
o
d
e
Displays the measured value (flow in l/min or l/h or accumulated consumption in
m´ or l). Flashing value means: measurement is outside the permitted measuring
range or the tubing is not correct.
S
Operate the SFE1−LF−... with different flow
values.
The number and bar display will change
accordingly.
Fig.11
Summary of Contents for SFE1-LF F10 Series
Page 28: ...SFE1 LF Festo SFE1 LF 0503NH Deutsch 28 1 1 Grundzustand RUN Modus Bild 22 SHOW Modus ...
Page 30: ...SFE1 LF Festo SFE1 LF 0503NH Deutsch 30 ...
Page 56: ...SFE1 LF Festo SFE1 LF 0503NH English 56 1 1 Basic status RUN mode Fig 22 SHOW mode ...
Page 58: ...SFE1 LF Festo SFE1 LF 0503NH English 58 ...
Page 59: ...SFE1 LF Festo SFE1 LF 0503NH 59 de Lochbilder en Hole pattern ...