Festo SFAM-62 Operating Instructions Manual Download Page 4

Fig.11

The  following  settings  are  displayed  for  OUTA:
With  flow  measurement  [FLW]:
 the  switching  function  (threshold  value  or  window  comparator)
 switching  point  [SP],  switching  points  [SP.Lo]  and  [SP.Hi]
 hysteresis  [Hy]
 switching  element  function  [no/nc]  (closer/opener)
 minimum  flow  value  [F.Lo]  (Flow  Low)

In  order  to  delete  the  minimum  value,  press  the  EDIT  button  briefly.

 maximum  flow  value  [F.Hi]  (Flow  High)

In  order  to  delete  the  maximum  value,  press  the  EDIT  button  briefly.

With  air  consumption  measurement  [ConS]:
 consumption  impulse  [CI]
 switching  element  function  [no/nc]  (closer/opener)
 minimum  flow  value  [F.Lo]  (Flow  Low)

In  order  to  delete  the  minimum  value,  press  the  EDIT  button  briefly.

 maximum  flow  value  [F.Hi]  (Flow  High)

In  order  to  delete  the  maximum  value,  press  the  EDIT  button  briefly.

The  following  settings  are  displayed  for  OUTB:
 the  switching  function  (threshold  value  or  window  comparator)
 switching  point  [SP],  switching  points  [SP.Lo]  and  [SP.Hi]
 hysteresis  [Hy]
 switching  element  function  [no/nc]  (closer/opener)
 colour  change  status  [bLUE/rON/rOFF]
 minimum  flow  value  [F.Lo]

In  order  to  delete  the  minimum  value,  press  the  EDIT  button  briefly.

 maximum  flow  value  [F.Hi]

In  order  to  delete  the  maximum  value,  press  the  EDIT  button  briefly.

5.4 EDIT  mode

Fig.12

Summary of Contents for SFAM-62

Page 1: ...tion SFAM T or combination with service units of the MS series SFAM M Measurement is carried out by means of a thermal procedure The amount of heat which is drawn from a heated surface of the sensor b...

Page 2: ...ed to the connection where the sieve cartridge on type SFAM M or the starting stretch on type SFAM T is situated The air mass flow is taken from the opposite connection In order to maintain the accura...

Page 3: ...pressing Edit button for 3 seconds or passage of a monitoring time timeout 1 Switch on the operating voltage The SFAM is in RUN mode 2 Check the settings of the SFAM chapter 5 3 SHOW mode 5 1 Symbols...

Page 4: ...e CI switching element function no nc closer opener minimum flow value F Lo Flow Low In order to delete the minimum value press the EDIT button briefly maximum flow value F Hi Flow High In order to de...

Page 5: ...Hy flashes 8 Set the value for the hysteresis Hy with the A B buttons 9 Press the Edit button to confirm the set value no or nc flashes 10 Select the switching element function no nc with the A B but...

Page 6: ...oothing to d6 maximum smoothing With increasing smoothing the switch on switch off time of the switch outputs rises With d OFF the response time of the analogue output equals the set response time Sig...

Page 7: ...be compared e g operating volume flow amount supplied by a compressor measured values of a flow sensor from another manufacturer refer to the same basic conditions After the power supply is switched...

Page 8: ...Electronics Operating voltage range DC V 15 30 Protection against polarity reversal For all electrical connections Electromechanics Electrical connection Straight plug M12x1 5 pin Max length of connec...