Consumption  switch  impulse  [CI]  with  accumulated  air  consumption
measurement

Setting  NO  (normally  open    closer)

Setting  NC  (normally  closed    opener)

CI

CI

t

t

0

OUTA

1

0

CI

100ms

[l],  [m´]

CI

CI

t

t

0

OUTA

1

0

CI

100ms

[l],  [m´]

Fig.10

A  threshold  value  for  air  consumption  can  be  set  with  the  consumption  switch
impulse  [CI].  If  the  set  threshold  value  is  reached,  a  switch  impulse  is  emitted  at
the  output  Out  A  for  100  ms.  With  each  switch  impulse,  measurement  of  the  air
consumption  is  started  again.

Symbols  on  the  display

Symbols

Description

Out  A/Out  B

Switching  output  A  /  switching  output  B

Lock

Security  code  is  active  (locked  against  unauthorized  programming)

Run

Accumulated  air  consumption  measurement  is  active  in  the  Recorder  mode

Option

The  sensor  is  set  to  a  standard  condition  that  differs  from  the  factory  setting

è

  chapter  5.4,  Setting  standard  condition  section

Stop

Reset  accumulated  air  consumption  measurement  value

Switching  output  set/not  set

Threshold  comparator

Window  comparator

Air  consumption  switching  mode  (consumption    only  for  Out  A)

Impulse  for  accumulated  air  consumption  (consumption  impulse)

Switching  point

Lower  switching  point

Upper  switching  point

Hysteresis

Normally  open  contact

Normally  closed  contact

Switching  mode  flow  (flow    only  with  Out  A)

Minimum  flow  (flow  low)

Maximum  flow  (flow  high)

Special  menu

Analogue  filter

Digital  filter

Display  red  with  switching  status  ON  or  logical  1

Display  red  with  switching  status  OFF  or  logical  0

Output  plus  switch

Output  zero  switch

Segments  light  up:  graphic  display  of  the  current  measured  value  in  relation
to  the  max.  measured  value  of  the  measuring  range.

Running  light  (1  segment):  Air  consumption  measurement  for  Out  A  or
RECORDER  mode  active

3  segments  flashing:  Hysteresis  value  is  displayed

1  segment  flashing:
 Segment  6:

switching  point  SP  or  SP.Lo  will  be  displayed

 Segment  8:

switching  point  SP.Hi  will  be  displayed

 Segment  1:

min.  flow  (F.Lo)  will  be  displayed

 Segment  10:

max.  flow  (F.Hi)  will  be  displayed

Fig.11

Preparing  commissioning

In  the  base  state,  the  product  is  in  the  RUN  mode.  The  current  measurement
values  are  displayed.  The  base  state  can  be  reached  from  other  modes  by:
 pressing  Edit  button  for  3  seconds  or
 passage  of  a  monitoring  time,  timeout
1.

Switch  on  the  operating  voltage.
The  SFAB  is  in  the  RUN  mode.

2.

Check  the  settings  of  the  SFAB 

è

  chapter  5.3  SHOW  mode.

5.1 Icons  for  representing  the  menu  structure

Icon

Meaning

Automatic  return  to  the  basic  status  (RUN  mode)  when  the  monitoring  time
has  expired  (here  80  seconds)

In  order  to  return  to  the  basic  status  (RUN  mode),  press  the  Edit  button  for
3seconds

Create  flow  (for  teaching  the  measured  value    here  flow  1)

Symbol  on  the  display  flashes  (here  Out  B)

Security  code  active  (Lock    blocked  against  unauthorised  programming)

Security  code  inactive  (Lock)

Press  button  (here  A  button)

Press  A  button  or  B  button.  Then  the  SFAB  switches  to  the  setting  shown  by
the  arrows

Press  A  button  and  B  button  simultaneously

Press  button  (here  A  button)  and  Edit  button  simultaneously

Press  A  button  or  B  button  and  thus  set  the  desired  value

Display  for  a  value  or  switching  point.  Value  can  be  set

Press  the  Edit  button

Branched  in  the  menu

Fig.12

5.2 RUN  mode

In  the  RUN  mode
 the  measurement  values  for  flow  (in  l/min,  scfm  or  l/h)
 the  measurement  values  for  air  consumption  (in  m´,  scf  or  l)  and
 the  signal  states  of  the  switch  outputs  Out  A,  Out  B  (set,  not  set)  are  displayed.

Note

A  flashing  value  means:
 measurement  outside  the  permitted  measuring  range  or
 incorrectly  connected  hoses 

è

  chapter  4.2  Pneumatic  connection

5.3 SHOW  mode

In  the  SHOW  mode,  the  current  settings  for  the  switching  outputs  Out  A  and  Out  B
are  displayed.
The  SFAB  must  be  in  the  RUN  mode.
· Pressing  the  A  button  (switching  output  Out  A)  or  the  B  button  (switching  output

Out  B)  starts  the  SHOW  mode  for  the  respective  switching  output.

Note

If  there  are  faults,  pressing  the  A  button  /  B  button  first  displays  corresponding
fault  numbers.

· Repeated  pressing  of  the  A  button/B  button  displays  the  settings  of  the

respective  switching  output  one  after  another.

· When  all  settings  have  been  displayed,  the  SFAB  goes  back  into  the  RUN  mode

when  the  A  button/B  button  are  pressed  again  and  displays  the  current
measurement  value  for  the  corresponding  output.

As  a  result,  the  displays  can  also  be  changed  via  the  SHOW  mode  to  switch
between  the  displayed  measurement  values,  such  as  with  a  combination  of  air
consumption  measurement  and  flow  measurement.

Summary of Contents for SFAB-10U

Page 1: ...ing systems or end devices in industry suitable media è chapter 11 Technical specifications Measurement is carried out by means of a thermal procedure The amount of heat which is drawn from a heated surface of the sensor by the medium flowing through it is calculated here Through the amount of heat removed the flow or accumulated air consumption is determined and shown on the display The connectio...

Page 2: ... hoses into the PlugInconnections of connection 1 and connection 2 è Marking on the product Note If the hoses are connected to the SFAB incorrectly the measurement values will flash in the display 4 3 Electrical connection Warning Use only power units which guarantee reliable electrical isolation of the operating voltage as per IEC DIN EN 60204 1 Observe also the general requirements for PELV powe...

Page 3: ...ate can be reached from other modes by pressing Edit button for 3 seconds or passage of a monitoring time timeout 1 Switch on the operating voltage The SFAB is in the RUN mode 2 Check the settings of the SFAB è chapter 5 3 SHOW mode 5 1 Icons for representing the menu structure Icon Meaning Automatic return to the basic status RUN mode when the monitoring time has expired here 80 seconds In order ...

Page 4: ...g impulse CI switching element function no nc closer opener minimum flow value F Lo Flow Low In order to delete the minimum value press the EDIT button briefly maximum flow value F Hi Flow High In order to delete the maximum value press the EDIT button briefly The following settings are displayed for OUT B the switching function threshold value or window comparator switching point SP switching poi...

Page 5: ...s 8 Set the value for the hysteresis Hy with the A B buttons 9 Press the Edit button to confirm the set value no or nc flashes 10 Select the switching element function no nc with the A B buttons 11 Press the Edit button to confirm the set value The SFAB is in the RUN mode Carry out a test run with various flows to ascertain whether the SFAB switches as desired switching points and hysterisis b Set...

Page 6: ...IG F with the currently chosen value flashes The digital filter can be set d Setting smoothing for the digital filter The display values can be smoothed with the digital filter The degree of smoothing can be set in 6 steps from d1 low smoothing to d6 maximum smoothing With increasing smoothing the switch on switch off time of the switch outputs rises With d OFF the response time of the analogue ou...

Page 7: ...a flow sensor from another manufacturer refer to the same basic conditions After the power supply is switched on the SFAB needs a warm up time of 5 minutes until it achieves the specified accuracy 6 1 Resetting the SFAB to the factory settings also if the security code cannot be found Note The current settings will be lost after a reset to the factory setting If necessary make a note of these sett...

Page 8: ... 0 Ū 10 Max load resistance at current output Ohm 500 Min load resistance at voltage output kOhm 10 Rise time ms 15 30 60 factory setting 125 250 500 999 adjustable Output additional data Protection against short circuit yes Protection against overloading yes Electronics Operating voltage range DC V 15 Ū 30 Protection against polarity reversal for all electrical connections Electromechanics Electr...

Reviews: