Vibration load
Frequency range [Hz]
Acceleration [m/s
2
]
Deflection [mm]
SG1
SG1
SG1
2 … 8
–
± 3.5
8 … 41
10
–
41 … 58
–
± 0.15
58 … 160
20
–
160 … 200
10
–
Tab. 9 Values for vibration and shock in accordance with IEC 60068
Shock load
Acceleration [m/s
2
]
Duration [ms]
Shocks per direction
SG1
SG1
SG1
± 150
11
5
Tab. 9 Values for vibration and shock in accordance with IEC 60068
Continuous shock load
Acceleration [m/s
2
]
Duration [ms]
Shocks per direction
± 150
6
1000
Tab. 9 Values for vibration and shock in accordance with IEC 60068
12.2
Technical data, pneumatic
MSE6-D2M
[bar]
3.5 … 13
Operating pressure
[MPa]
0.35 … 1.3
Medium
Operating medium
Compressed air to ISO 8573-1:2010 [7:4:4]
Nitrogen
Note
Lubricated operation not possible
Temperature of medium
[°C]
0 … 50
Mounting position
Horizontal ± 5°
Flow rate
Standard nominal flow rate
1)
1
}
2 in main flow direction
[l/min]
4500
Standard nominal flow rate
1)
2
}
1 in relief direction
[l/min]
4500
2)
Pressure sensor
3)
[bar]
0 … 14
Pressure measuring range
[MPa]
0 … 1.4
Accuracy
[%FS]
± 3
Repetition accuracy
[%FS]
± 0.3
Flow sensor
3)4)
Flow direction
Unidirectional P1
}
P2
Flow measuring range
[l/min]
50 … 5000
Accuracy of flow rate
± (3 % of measured value + 0.3 % FS)
Repetition accuracy, zero
point
[%FS]
± 0.2
Repetition accuracy, margin
[%FS]
± 0.8
Temperature coefficient,
margin
[%FS/K]
Type ± 0.1
[±FS/bar%]
± 0.5
Pressure-dependent margin
[±FS/bar%]
± 5
Shut-off valve
[bar]
<
3.5
Switch-on pressure
[MPa]
<
0.35
[bar]
<
1
Switch-off pressure
[MPa]
<
0.1
[bar]
<
1
Residual pressure
[MPa]
<
0.1
Degree of protection in
accordance with EN 60529
IP65
5)
1) measured at P1 = 6 bar (0.6 MPa) and P2 = 5 bar (0.5 MPa). Δp = 1 bar (0.1 MPa).
2) shut-off valve in the "Pressurise" status
3) % FS = percent of the measurement value range end value (full-scale)
4) Typical accuracy with nominal conditions (6 bar (0.6 MPa), 23 °C and horizontal mounting position)
5) plug connector inserted or fitted with protective cap
Tab. 10 Technical data, pneumatic
12.3
Technical data, electrical
MSE6-D2M
Operating voltage supply for the electronics/sensors
Nominal voltage
[V DC]
24 ± 25 %
Nominal voltage range
[V DC]
18 … 30
Current consumption at 24 V
[mA]
Max. 250
MSE6-D2M
Load voltage supply for actuators
Nominal voltage
[V DC]
24 – 25 %/+ 20 %
Nominal voltage range
[V DC]
18 … 28.8
Current consumption
[mA]
Max. 100
Undervoltage diagnostic
message (trigger level
without hysteresis)
[V]
15 … 17
Electromagnetic compatibility
Interference emission
è
Declaration of conformity (www.festo.com).
Immunity to interference
è
Declaration of conformity (www.festo.com).
Tab. 11 Technical data, electrical