background image

Vibration load

Frequency range [Hz]

Acceleration [m/s

2

]

Deflection [mm]

SG1

SG1

SG1

2 … 8

± 3.5

8 … 41

10

41 … 58

± 0.15

58 … 160

20

160 … 200

10

Tab. 9 Values for vibration and shock in accordance with IEC 60068

Shock load

Acceleration [m/s

2

]

Duration [ms]

Shocks per direction

SG1

SG1

SG1

± 150

11

5

Tab. 9 Values for vibration and shock in accordance with IEC 60068

Continuous shock load

Acceleration [m/s

2

]

Duration [ms]

Shocks per direction

± 150

6

1000

Tab. 9 Values for vibration and shock in accordance with IEC 60068

12.2

Technical data, pneumatic

MSE6-D2M

[bar]

3.5 … 13

Operating pressure

[MPa]

0.35 … 1.3

Medium

Operating medium

Compressed air to ISO 8573-1:2010 [7:4:4]

Nitrogen

Note

Lubricated operation not possible

Temperature of medium

[°C]

0 … 50

Mounting position

Horizontal ± 5°

Flow rate

Standard nominal flow rate

1)

}

 2 in main flow direction

[l/min]

4500

Standard nominal flow rate

1)

}

 1 in relief direction

[l/min]

4500

2)

Pressure sensor

3)

[bar]

0 … 14

Pressure measuring range

[MPa]

0 … 1.4

Accuracy

[%FS]

± 3

Repetition accuracy

[%FS]

± 0.3

Flow sensor

3)4)

Flow direction

Unidirectional P1 

}

 P2

Flow measuring range

[l/min]

50 … 5000

Accuracy of flow rate

± (3 % of measured value + 0.3 % FS)

Repetition accuracy, zero
point

[%FS]

± 0.2

Repetition accuracy, margin

[%FS]

± 0.8

Temperature coefficient,
margin

[%FS/K]

Type ± 0.1

[±FS/bar%]

± 0.5

Pressure-dependent margin

[±FS/bar%]

± 5

Shut-off valve

[bar]

<

 3.5

Switch-on pressure

[MPa]

<

 0.35

[bar]

<

 1

Switch-off pressure

[MPa]

<

 0.1

[bar]

<

 1

Residual pressure

[MPa]

<

 0.1

Degree of protection in
accordance with EN 60529

IP65

5)

1) measured at P1 = 6 bar (0.6 MPa) and P2 = 5 bar (0.5 MPa). Δp = 1 bar (0.1 MPa).
2) shut-off valve in the "Pressurise" status
3) % FS = percent of the measurement value range end value (full-scale)
4) Typical accuracy with nominal conditions (6 bar (0.6 MPa), 23 °C and horizontal mounting position)
5) plug connector inserted or fitted with protective cap

Tab. 10 Technical data, pneumatic

12.3

Technical data, electrical

MSE6-D2M

Operating voltage supply for the electronics/sensors

Nominal voltage

[V DC]

24 ± 25 %

Nominal voltage range

[V DC]

18 … 30

Current consumption at 24 V

[mA]

Max. 250

MSE6-D2M

Load voltage supply for actuators

Nominal voltage

[V DC]

24 – 25 %/+ 20 %

Nominal voltage range

[V DC]

18 … 28.8

Current consumption

[mA]

Max. 100

Undervoltage diagnostic
message (trigger level
without hysteresis)

[V]

15 … 17

Electromagnetic compatibility

Interference emission

è

 Declaration of conformity (www.festo.com).

Immunity to interference

è

 Declaration of conformity (www.festo.com).

Tab. 11 Technical data, electrical