background image

Translation of the original instructions

PI PROFIBUS PROFINET

®

 is a registered trademark of its respective trademark

holder in certain countries.

1

Applicable documents

All available documents for the product 

è

 www.festo.com/pk.

Document

Product

Contents

Description

Energy efficiency module MSE6-D2M-SY

Function, Paramet-
erisation

Description

CPX system description P.BE-CPX-SYS-…

Installation, Commis-
sioning

Description

PROFINET bus node IO P.BE-CPX-PNIO-…

PROFINET

Tab. 1 Documentation on the product

2

Safety

2.1

Safety instructions

Only use the product in original status without unauthorised modifications.

Only use the product if it is in perfect technical condition.

Only use the product in an industrial environment.

This product can generate high frequency malfunctions, which may make it
necessary to implement interference suppression measures in residential
areas.

Observe labelling on the product.

Prior to mounting, installation and maintenance work: Switch off power sup-
ply and secure it from being switched back on. Only switch on the power sup-
ply when the product has been assembled and installation and maintenance
work is complete.

Product is opened in normal position (pressurisation status). If the minimum
supply voltage is exceeded at the control extension series 1 device, the
product switches to the pressurisation status.

Note that, when the inlet pressure is switched off, depending on the function
a residual pressure of < 1 bar (< 0.1 MPa) can remain at the output

è

 Standby detection and automatic blocking of the compressed air supply.

2.2

Intended use

The purpose of the energy efficiency module MSE6-D2M is to monitor the com-
pressed air and the energy-efficient supply of pneumatic systems.

2.3

Foreseeable misuse

The following examples of foreseeable misuse are among those not approved as
intended use:

Outdoor use

Not mounted on the mounting plate

Exhaust ports sealed

2.4

Training of qualified personnel

Installation, commissioning, service and disassembly should only be conducted
by skilled personnel. The skilled personnel must be familiar with the installation
of electrical and pneumatic control systems.

3

Additional information

Accessories 

è

 www.festo.com/catalogue.

Spare parts 

è

 www.festo.com/spareparts.

Information on the CPX field bus node 

è

 www.festo.com/sp.

Information on the short documentation for the CPX-Extension

è

 www.festo.com/sp.

4

Service

Contact your regional Festo contact person if you have technical questions

è

 www.festo.com.

5

Product overview

5.1

Configuration

5.1.1

Product design

1 Pneumatic connection 1:

Input for compressed air 

2 Pneumatic connection 2:

Output for compressed air 

3 Shut-off valve with pressure

sensor

4 Pressure gauge

5 CPX-Extension series 2 connec-

tion

6 Flow sensor

7 Status LEDs

Fig. 1 Product design

5.1.2

Display components

LED

Meaning

P2 (green)

LED illumin-
ated

Outlet pressure p2 

³

 lower limit value pressure p2

LED is off

Outlet pressure p2 

<

 lower limit value pressure p2

P

 (red)

LED illumin-
ated

Module error

LED is off

No module error

Tab. 2 Display of status LED

5.1.3

Connecting components

The product has a CPX-Extension series 2 connection. Use only the preassembled
extension connecting cables from Festo 

è

 www.festo.com/catalogue.

5.2

Functions

Overview

Control function (energy efficiency function)

Automatic blocking if flow is too low

User-controlled blocking and pressurisation

Recording and provision of measurement data

Outlet pressure

Pressure change (for pressure tightness testing)

Flow rate

Air consumption

Limit monitoring

Pressure, lower and upper limit value

Pressure change, upper limit value

Flow rate, upper limit value

CPX-Extension connection for connecting to a CPX field bus node (decentral-
ised device that must be connected via a special connecting cable to a device
with extension series 1 interface, e. g. energy efficiency module MSE6-C2M,
CPX terminal).

Standby detection and automatic blocking of the compressed air supply

The product detects downtimes of a pneumatic system upon corresponding para-
meterisation. The system is separated from the compressed air supply using the
shut-off valve without exhausting the downstream system. If the product receives
a release signal in the automatically activated blocking mode, the shut-off valve
opens, and the system is again supplied with compressed air. Automatic blocking
of the compressed air supply can be activated and deactivated by the user. In the
deactivated status, the shut-off valve can be controlled directly by the machine
controller. After exhausting via connection 1, a residual pressure of 

<

 1 bar can

remain at connection 2.

Pressure tightness testing

When in the blocked state, the product measures the pressure curve over time.
The measured pressure change serves as a measure for the existing leakage in
the system. If the parameterised limit value is exceeded, the product issues a dia-
gnostic message via the bus node in extension series 1.

Pressure recording

The product continuously measures the outlet pressure, prepares the data and
makes it available cyclically. To detect excessive operating pressures, the product
offers the option of parameterising limit values for pressure. If the parameterised
limit value is exceeded, the product will issue a diagnostic message via the CPX-
Extension series 2 connection to the bus node.

8095314

MSE6-D2M

Energy efficiency module

8095314
2018-09
[8095316]

Instructions | Operating

Festo AG & Co. KG
Ruiter Straße 82
73734 Esslingen
Germany
+49 711 347-0

www.festo.com

Reviews: