Eliminating faults

Fault

Possible cause

Remedy

No pressure display

Shut-off valve closed

Open shut-off valve

Pressure not set

Set pressure with pressure setting button

Manometer defective

Replace manometer

Pressure increases above set operating
pressure

Defective valve poppet on sealing seat

Return to Festo

Exhaust can be heard at setting button

Valve seat damaged

Return to Festo

Störungsbeseitigung

Störung

mögliche Ursache

Abhilfe

Keine Druckanzeige

Absperrventil geschlossen

Absperrventil öffnen

Druck nicht eingestellt

Mit Druckeinstellschraube Druck einstellen

Manometer defekt

Manometer austauschen

Druck steigt an über den eingestellten 
Betriebsdruck

Ventilkegel am Dichtsitz defekt

Festo zusenden

Hörbares Abblasen am Einstellknopf

Ventilsitz beschädigt

Festo zusenden

6

Åtgärder vid fel

Störning

Möjlig orsak

Åtgärd

Ingen tryckindikering

Avstängningsventilen stängd

Öppna avstängningsventilen

Trycket inte inställt

Ställ in trycket med tryckinställningsskruven

Defekt manometer

Byt manometer

Trycket stiger över det inställda 
arbetstrycket

Ventilkäglan vid tätningssätet defekt

Återsänd till Festo

Hörbar utblåsning vid inställningsvredet

Ventilsätet skadat

Återsänd till Festo

LR-...-G-... 

                                       

9701 NH

D/GB/S 6

Summary of Contents for LR G Series

Page 1: ...ienungsanleitung Fitting and commissioning to be carried out by qualified personnel only in accordance with the operating instructions Montering och idrifttagande f r endast utf ras av auktoriserad fa...

Page 2: ...he product must be observed at all times Please observe the limits for pressures forces torques masses speeds temperatures and electric voltages Please observe the prevailing ambient conditions Please...

Page 3: ...aking the system pressureless for fitting and maintenance Please note the direction of flow from 1 to 2 This is shown by the arrows 6 Decide how you wish to fasten the pressure regulator Front panel f...

Page 4: ...e blind plug Commissioning Adjusting the regulator LR 1 Slowly pressurize the complete system 2 Pull the pressure setting button 4 upwards away from the housing 3 Turn the pressure setting until the d...

Page 5: ...e Observe the regulating accuracy of the LR in operation If the LR regulates above the toler ance limit remove any dirt Cleaning Use only the cleaning agents speci fied Component Cleaning agent LR Wat...

Page 6: ...ruck nicht eingestellt Mit Druckeinstellschraube Druck einstellen Manometer defekt Manometer austauschen Druck steigt an ber den eingestellten Betriebsdruck Ventilkegel am Dichtsitz defekt Festo zusen...

Page 7: ...reich 10 C 80 C Werkstoffe Geh use CuZn Messing Dichtungen Membrane NBR Drehknopf PA R ndelmutter Al max Hysterese 0 2 bar 7 Technical specifications Type LR 1 8 G LR 1 8 G 7 Part no 159 505 159 506 D...

Page 8: ...ngad anslutning tryckluft G 1 8 G 1 8 manometer G 1 8 Tryckomr de till tet matartryck reglerintervall max 20 bar 0 5 12 bar max 20 bar 0 5 7 bar Nominellt fl de 600 l min 700 l min Till tet temperatur...

Reviews: