HSP-...-AP/A S
Festo HSP-...-AP/AS 2017-10b English
16
Fitting: Electric components
Use proximity switches SME/SMT-8 for
scanning the end positions:
1. Remove the protective cover of the
handling module.
2. Make sure that the shock absorbers are
screwed in completely (only type ...-AP; as
supplied from the factory).
3. Push the proximity switch into the groove
of the sensor rail (A).
The electric proximity switches are trig
gered by magnets in the stop screws (B).
4. Fasten the proximity switches in the end
positions. Subsequent adjustment of the
shock absorbers is not necessary.
Please note
The cables of the proximity switches must not lie in the working range of the
handling module.
S
Clamp the cables in the groove of the side plates (D) and the sub-base.
S
Secure the cables with the aid of the cover profile (C) of the installation kit
(cut to size).
S
Paass the cables back through the through hole in the sub-base (E).
Fig. 19
(A)
(B)
(D)
(E)