HMP−...−B−...−Z..−...
Festo HMP−...−B−...−Z..−... 0412NH English
30
10
Technical specifications
Type
HMP−....−Z..−...
−16−...−B−
−20−...−B−
−25−...−B−
−32−...−B−
Design
Double−acting pneumatic cylinder with swivelling
stop lever
Mounting position
As desired
Medium
Filtered, lubricated or non−lubricated compressed
air (filter fineness min. 40 m)
Operating pressure range
4 ... max. 8 bar
Connecting thread
M3
Permitted temperature range
0 ... max. 60 °C (ambient)
Theoretical effective power at
6bar
17 N
Leakage, measured at 6 bar
< 2 Nl/h (when new)
Swivel time
extending
retracting
0.04 s
0.04 s
0.04 s
0.036 s
0.04 s
0.034 s
0.072 s
0.065 s
Max. stroke frequency [1/s]
(not for continuous operation)
10
5
Permitted cushioning energy with
shock absorber type YSRW−...
4 Nm
12 Nm
12 Nm
35 Nm
Max. impact force [N]
500
1000
1000
2000
Repetition accuracy
*)
< 0.01 mm
Materials
Housing:
Al, anodized
Stop lever:
St
O−rings, seals:
NBR
slide bearing:
POM
Weight [g]
165
206
227
321
*)
During 100 consecutive strokes under constant operating conditions
Fig.21