8
Care and maintenance
S
If the clamping unit is dirty, clean it with a soft cloth.
Permitted cleaning agents are:
– soap suds (max. 60 °C)
– all non-abrasive agents.
9
Dismantling and repairs
Warning
Pre-stressed springs may expand suddenly when the unit is dismantled.
S
Make sure that the clamping unit is not dismantled. Please contact our after-
sales repairs service for maintenance and repairs to the clamping unit.
Dismantling
S
Make sure that the work load has reached a stable position (e.g. at the lowest
point if fitted in a vertical position).
S
Exhaust the clamping unit.
S
Do not modify the settings of screws and threaded pins if there is no request to
do this in these operating instructions.